10
Eastwood Technical Assistance: 800.343.9353 >> [email protected]
PROBLEM
CAUSE
CORRECTION
Plasma Cutter Will
Not Power Up;
GREEN Indicator
Does Not Illuminate
Plasma Cutter not plugged into
proper power supply
Check power supply. The VERSA-CUT 60 requires a properly grounded,
120 Volt AC, 20 Amp or 240 Volt AC, 50 Amp circuit.
Power supply breaker tripped
Reset breaker.
Power switch not fully on
Check that Power Switch is fully “ON”, GREEN indicator illuminates.
Duty Cycle exceeded; Plasma
Cutter overheated;
AMBER indicator illuminated
Turn Power switch OFF, allow Plasma Cutter 15 minutes to cool then re-try.
Plasma Cutter
Shuts Off During
Use While the
Power Switch is On,
AMBER Indicator
Illuminated
Plasma Cutter Duty Cycle has
been exceeded
Turn Power switch OFF, allow Plasma Cutter 15 minutes to cool then re-try.
Water Drips from
the Rear Underside
of the Unit
The internal Moisture Trap is draining
No action required. This feature activates whenever the compressed air
source is disconnected.
TROUBLESHOOTING: OPERATIONAL PROBLEMS