POWER ON AND INITIALIZATION
• The “
POWER
” Switch is located on the left side of
the cabinet, at the upper, rear corner. Switch it to the
“
ON
” position.
• After the machine is powered on, it starts initialization
automatically. The initialization completes after two
seconds. The Balancer then enters normal Dynamic
Balance Mode automatically, ready for the input of
diameter, width and offset wheel data
(FIG 9)
.
INPUTTING OFFSET, WIDTH AND DIAMETER WHEEL RIM DATA
•
Enter Wheel Rim Offset
– The built-in Wheel Measure-
ment Scale is located at the front, upper edge of the
Cabinet
(FIGS 10 & 11)
. Pull it out and apply the roller to
the inner edge of the wheel rim. Observe and record the
Offset dimension which is Value “
a
”. Press “
a-
” or “
a+
”
Keys to enter Value “
a
”.
•
Enter Wheel Rim Width
– Using the included Wheel Width/
Diameter Caliper
[S]
, observe and record the Width dimen-
sion which is Value “
b
”. Press “
b-
” or “
b+
” Keys to enter
Value “
b
”.
• Enter Wheel Rim Diameter
– Using the included Wheel
Width/Diameter Caliper
[S]
, observe and record the Diam-
eter dimension which is Value “
d
”. Press “
d-
“ or “
d+
” Keys
to enter Value “
d”
.
FIG. 9