and Single-phase 2-wire unbalanced. Line frequency measured from L1 voltage or L3 voltage.

Three current inputs (six physical terminals) with 2·5mm2 stranded wire capacity for connection of external

CTs. Nominal rated input current 5A or 1A a.c. Rms.

5.3

5.3

5.3

5.3 Accuracy

Accuracy

Accuracy

Accuracy

Voltage

0·5% of range maximum

Current

0·5% of nominal

Frequency

0·2% of mid-frequency

Power factor

1% of unity (0.01)

Active power (W)

±1% of range maximum

Reactive power (VAr)

±2% of range maximum

Apparent power (VA)

±1% of range maximum

Active energy (Wh)

Class 1 IEC 62053-21

Reactive energy (VARh)

±2% of range maximum

Total harmonic distortion

1% up to 31st harmonic

Temperature co-efficient

Voltage and current = 0.013%/°C typical

Active energy = 0·018%/°C, typical

Response time to step input

1s, typical, to >99% of final reading, at 50 Hz.

5.4

5.4

5.4

5.4 Auxiliary

Auxiliary

Auxiliary

Auxiliary Supply

Supply

Supply

Supply

Two-way fixed connector with 2·5mm2 stranded wire capacity.

85 to 275V a.c. 50/60Hz ±10% or 120V to 380V d.c. ±20%. Consumption < 10W.

5.5

5.5

5.5

5.5 Interfaces

Interfaces

Interfaces

Interfaces for

for

for

for External

External

External

External Monitoring

Monitoring

Monitoring

Monitoring

Three interfaces are provided:

an RS-485 communication channel that can be programmed for Modbus RTU protocol

an relay output indicating real-time measured energy.(configurable)

an pulse output 3200imp/kWh (not configurable)

The Modbus configuration (Baud rate etc.) and the pulse relay output assignments (kW/kVArh,

import/export etc.) are configured through the Set-up screens.

5.5.1

5.5.1

5.5.1

5.5.1 Pulse

Pulse

Pulse

Pulse Relay

Relay

Relay

Relay Output

Output

Output

Output

The pulse relay output can be set to generate pulses to represent kWh or kVArh.

Rate

Rate

Rate

Rate

can be set to generate 1 pulse per:

0.01 = 10 Wh/VArh

0.1 = 100 Wh/VArh

1 = 1 kWh/kVArh

10 = 10 kWh/kVArh

100 = 100 kWh/kVArh

Pulse

Pulse

Pulse

Pulse width

width

width

width

200/100/60 ms.

Relay

Relay

Relay

Relay Rating

Rating

Rating

Rating

240V ac 50mA

Содержание SDM630

Страница 1: ...WEB www eastrongroup com Email sales eastrongroup com Add No 1369 Chengnan Road Nanhu Jiaxing Zhejiang China 314001 1 SMART SMART SMART SMART MINI MINI MINI MINI POWER POWER POWER POWER SDM630 SDM630 SDM630 SDM630 USER USER USER USER MANUAL MANUAL MANUAL MANUAL 2012 2012 2012 2012 V1 1 V1 1 V1 1 V1 1 ...

Страница 2: ...and and and and Operation Operation Operation Operation Instructions Instructions Instructions Instructions Important Safety Information is contained in the Maintenance section Familiarise yourself with this information before attempting installation or other procedures Symbols used in this document Risk of Danger These instructions contain important safety information Read them before starting in...

Страница 3: ...C or DC supply Alternatively it can be powered from the monitored supply where appropriate 1 1 1 1 1 1 1 1 Unit Unit Unit Unit Characteristics Characteristics Characteristics Characteristics The SDM630 can measure and display Line voltage and THD total harmonic distortion of all phases Line Frequency Currents Current demands and current THD of all phases Power maximum power demand and power factor...

Страница 4: ... up measured active and reactive energy The constant for reactive energy is 3200imp kVarh The pulse width for active energy can be set from the Set up menu 2 2 2 2 Start Start Start Start Up Up Up Up Screens Screens Screens Screens The first screen lights all display segments and can be used as a display check The second screen indicates the firmware installed in the unit and its build number Next...

Страница 5: ... up Mode this is the Left or Back button Select the Frequency and Power factor screens In Set up Mode this is the Up button Select the Power screens In Set up Mode this is the Down button Select the Energy display screens In Set up mode this is the Enter or Right button 3 1 3 1 3 1 3 1 Voltage Voltage Voltage Voltage and and and and Current Current Current Current Each successive pressing of the b...

Страница 6: ...com Add No 1369 Chengnan Road Nanhu Jiaxing Zhejiang China 314001 6 Phase to neutral voltage THD Current THD for each phase 3 2 3 2 3 2 3 2 Frequency Frequency Frequency Frequency and and and and Power Power Power Power factor factor factor factor and and and and demand demand demand demand Each successive pressing of the button selects a new range ...

Страница 7: ... www eastrongroup com Email sales eastrongroup com Add No 1369 Chengnan Road Nanhu Jiaxing Zhejiang China 314001 7 Frequency Power factor total Power factor of each phase Max Power demand Max Current demand 3 3 3 3 3 3 3 3 Power Power Power Power Each successive pressing of the button select a new range ...

Страница 8: ...rongroup com Add No 1369 Chengnan Road Nanhu Jiaxing Zhejiang China 314001 8 Instantaneous active power kW Instantaneous reactive power kVar Instantaneous Volt amps KVA Total kW kVarh kVA 3 4 3 4 3 4 3 4 Energy Energy Energy Energy Measurements Measurements Measurements Measurements Each successive pressing of the button selects a new range ...

Страница 9: ... 573 83698883 WEB www eastrongroup com Email sales eastrongroup com Add No 1369 Chengnan Road Nanhu Jiaxing Zhejiang China 314001 9 Imported active energy in kWh Exported active energy in kWh Imported reactive energy in kVarh Exported reactive energy in kVarh Total active energy in kWh ...

Страница 10: ...e button for 3 seconds until the password screen appears Setting up is password protected so you must enter the correct password default 1000 before processing If an incorrect password is entered the display will show PASS Err To exit setting up mode press repeatedly until the measurement screen is restored 4 1 4 1 4 1 4 1 Set up Set up Set up Set up Menu Menu Menu Menu Structure Structure Structu...

Страница 11: ... up Entry Entry Entry Entry Methods Methods Methods Methods Some menu items such as password and CT require a four digit number entry while others such as supply system require selection from a number of menu options 4 2 1 4 2 1 4 2 1 4 2 1 Menu Menu Menu Menu Option Option Option Option Selection Selection Selection Selection 1 Use the and buttons to select the required item from the menu shown i...

Страница 12: ...until the measurement screen is restored 4 2 2 4 2 2 4 2 2 4 2 2 Number Number Number Number Entry Entry Entry Entry Procedure Procedure Procedure Procedure When Setting up the unit some screens require the entering of a number In particular on entry to the setting up section a password must be entered Digits are set individually from left to right The procedure is as follows 1 the current digit t...

Страница 13: ...en will appear with the first digit flashing 3 Use and to set the first digit and press to confirm your selection The next digit will flash 4 Repeat the procedure for the remaining three digits 5 After setting the last digit SET will show 6 Press to exit the number setting routine and return to the Set up menu SET will be removed 4 4 4 4 4 4 4 4 DIT DIT DIT DIT Demand Demand Demand Demand Integrat...

Страница 14: ...d integration time 2 Press to enter the selection routine The current time interval will flash 3 Use and buttons to select the time required 4 Press to confirm the selection SET indicator will appear 5 Press to exit the dIT selection routine and return to the menu 4 5 4 5 4 5 4 5 Supply Supply Supply Supply System System System System Use this section to set the type of power supply being monitore...

Страница 15: ...required system option 3P4W 3P3W or 1P2W 4 Press to confirm the selection SET indicator will appear 5 Press to exit the system selection routine and return to the menu SET will disappear and you will be returned to the main Set up Menu 4 6 4 6 4 6 4 6 CT CT CT CT The CT option sets the primary current CT1 1 9999A and secondary current CT2 1A or 5A of the current transformer CT that wires to the me...

Страница 16: ...number to the maximum CT primary current e g 500A 4 On Completion of the entry procedure press to return to the main set up menu 5 Secondary CT setting The setting method is same as Primary Current setting CT1 4 7 4 7 4 7 4 7 PT PT PT PT The PT option sets the primary voltage PT1 100 500000V and secondary voltage PT2 100 500V of the Voltage transformer PT that wires to the meter The default value ...

Страница 17: ...pletion of the entry procedure press to confirm the setting and press to return to the main set up menu 5 Secondary PT setting The setting method is same as Primary voltage setting PT1 Max PT2 value is 500V 4 8 4 8 4 8 4 8 Pulse Pulse Pulse Pulse output output output output This option allows you to configure the pulse output The output can be set to provide a pulse for a defined amount of energy ...

Страница 18: ... set the energy represented by each pulse Rate can be set to 1 pulse per 0 01kWh 0 1kWh 1kWh 10kWh 100kWh It shows 1 impulse 10kWh kVarh 1 From the Set up menu use and buttons to select the Pulse Rate option 2 Press to enter the selection routine The current setting will flash 3 Use and buttons to choose pulse rate 0 01 0 1 1 10 100kWh kVarh per pulse 4 On Completion of the entry procedure press t...

Страница 19: ...ne The current setting will flash 3 Use and buttons to choose pulse width 200 100 60ms 4 On Completion of the entry procedure press to confirm the setting and press to return to the main set up menu 4 9 4 9 4 9 4 9 Communication Communication Communication Communication There is a RS485 port can be used for communication using Modbus RTU protocol For Modbus RTU parameters are selected from Front p...

Страница 20: ...outine The current setting will flash 3 Use and buttons to choose Baud rate 2 4k 4 8k 9 6k 19 2k 38 4k 4 On Completion of the entry procedure press to confirm the setting and press to return to the main set up menu 4 9 3 4 9 3 4 9 3 4 9 3 Parity Parity Parity Parity 1 From the Set up menu use and buttons to select the Parity option 2 Press to enter the selection routine The current setting will fl...

Страница 21: ... 9 4 4 9 4 4 9 4 Stop Stop Stop Stop bits bits bits bits 1 From the Set up menu use and buttons to select the Stop Bit option 2 Press to enter the selection routine The current setting will flash 3 Use and buttons to choose Stop Bit 2 or 1 4 On Completion of the entry procedure press to confirm the setting and press to return to the main set up menu 4 10 4 10 4 10 4 10 CLR CLR CLR CLR The meter pr...

Страница 22: ...tage voltage THD between phases three phase supplies only Current on each phase 1 to 9999A range set by external current transformer s CTs Current THD for each phase 5 1 2 5 1 2 5 1 2 5 1 2 Power Power Power Power factor factor factor factor and and and and Frequency Frequency Frequency Frequency and and and and Max Max Max Max Demand Demand Demand Demand Frequency in Hz Instantaneous power Power ...

Страница 23: ... of final reading at 50 Hz 5 4 5 4 5 4 5 4 Auxiliary Auxiliary Auxiliary Auxiliary Supply Supply Supply Supply Two way fixed connector with 2 5mm2 stranded wire capacity 85 to 275V a c 50 60Hz 10 or 120V to 380V d c 20 Consumption 10W 5 5 5 5 5 5 5 5 Interfaces Interfaces Interfaces Interfaces for for for for External External External External Monitoring Monitoring Monitoring Monitoring Three int...

Страница 24: ...nditions Conditions Conditions of of of of Influence Influence Influence Influence Quantities Quantities Quantities Quantities Influence Quantities are variables that affect measurement errors to a minor degree Accuracy is verified under nominal value within the specified tolerance of these conditions Ambient temperature 23 C 1 C Input waveform 50 or 60Hz 2 Input waveform Sinusoidal distortion fac...

Страница 25: ... 573 83698883 WEB www eastrongroup com Email sales eastrongroup com Add No 1369 Chengnan Road Nanhu Jiaxing Zhejiang China 314001 25 6 6 6 6 Case Case Case Case Dimensions Dimensions Dimensions Dimensions 7 7 7 7 Installation Installation Installation Installation Single phase two wire ...

Страница 26: ...RUMENTS CO LTD TEL 0086 573 83698881 83698882 FAX 0086 573 83698883 WEB www eastrongroup com Email sales eastrongroup com Add No 1369 Chengnan Road Nanhu Jiaxing Zhejiang China 314001 26 Three phase four wire Three phase three wires ...

Отзывы: