Plumbing
5B6331 – 01JUN99
45
Removing the DEVELOPER COOLING SOLENOID L2
Warning
Dangerous Voltage
[1] De-energize the PROCESSOR.
[2] Lift the TOP COVER.
[3] Remove the DRIVE SIDE PANEL.
[4] Install 2 CLAMPS TL-2170 on the 2 HOSES to the COOLING SOLENOID for the developer.
[5] Remove the HOSE CLAMPS and the HOSES.
[6] Remove the 2 SCREWS securing the COOLING SOLENOID to the BRACKET.
[7] Disconnect the CONNECTOR P/J23.
[8] Disconnect the ground wire by loosening the SCREW at the COOLING SOLENOID.
[9] Remove the COOLING SOLENOID.
[10] Remove and keep the 2 FITTINGS.
Caution
• Install the COOLING SOLENOID so that the A is at the top and the C is at the bottom.
• Apply only SEALANT TL-3230 on the FITTINGS. A different SEALANT might cause damage to the plastic in the
THERMOWELL. See the instructions packed with the SEALANT.
• Do not overtighten the parts during installation of the COOLING SOLENOID.
[11] Assemble the PROCESSOR.
[12] Check for leakage at the COOLING SOLENOID.