ADJUSTMENTS AND REPLACEMENTS
34
01JUN99 – 5B6331
Section 4: DRYER
Removing the BLOWER B1
Warning
Dangerous Voltage
[1] De-energize the PROCESSOR.
[2] Lift the TOP COVER.
[3] Remove:
• NON-DRIVE SIDE PANEL
• DRYER END PANEL
• 3 SCREWS holding the BLOWER BRACKET to the BASE PLATE
[4] Pull the BLOWER toward you and remove it from the PROCESSOR.
[5] Remove the SCREW and the STRAIN RELIEF from the BLOWER BRACKET.
[6] Disconnect the CONNECTOR P/J18.
[7] Disconnect the 2 wires from the CAPACITOR.
[8] Remove the 3 NUTS and separate the BLOWER from the BLOWER BRACKET.
[9] Transfer the BLOWER SLEEVE from the existing BLOWER to the new BLOWER.
[10] Install the new BLOWER and assemble the PROCESSOR.
Note
When you install the new BLOWER, be sure that the BLOWER SLEEVE is positioned correctly to prevent air leaks.
H150_0141HA
CAPACITOR
H150_0141HCA
3 WASHERS
3 SCREWS
P/J18
CONNECTOR
PLENUM
BASE PLATE
SLEEVE
BLOWER
BLOWER
3 NUTS
3 LOCK WASHERS
3 WASHERS
BLOWER
BRACKET
SCREW
LOCK WASHER
WASHER
STRAIN
RELIEF
3 LOCK WASHERS