the voltage is within the allowable range.
Do not connect the same PV string to multiple inverters in series; otherwise the inverter
may be damaged.
The photovoltaic module used with the inverter must comply with Class A standard of
IEC61730.
2.3 Safety of inverter
WARNING
Make sure that the voltage and frequency of the grid connection point meet the grid
connection specifications of the inverter.
It is recommended to provide the protection device such as circuit breaker or fuse on AC
side of the inverter, and the specification of the protection device should be greater than
1.25 times the rated AC output current of the inverter.
The protective earth conductor of the inverter must be connected firmly. When multiple
inverters are used, make sure that equipotential connection is made for all protection
ground points on the inverter housing.
If the photovoltaic system is not equipped with a battery, it is not recommended to use the
BACK-UP function. The power consumption risk of the system caused thereon is
excluded in the warranty of the equipment manufacturer.
DANGER
After installation of the inverter, labels and warning signs on the box must be clearly
visible, and shall not be covered, changed and damaged.
The signs on the inverter box are as follows:
There is high temperature on the
surface of the inverter, and it is
forbidden to touch the inverter
when it is running, otherwise it is
possible to cause burns
Delayed discharge. After the
inverter is powered down, please
wait for 5 minutes till the inverter
is fully discharged
Please read the user manual
carefully before operating the
inverter
Potential danger may be caused
during the operation of the
inverter, and protection measures
should be taken
The inverter should not be treated
as domestic waste, please dispose
the inverter according to local laws
and regulations, or send it back to
the equipment manufacturer
Connection point of protective
earth conductor
CE Marking
RCM Marking