9
电机不振动
no vibration by the
motor in the
seat-pad
①、振动电机坏
Vibration motors failed
②、端子接触不良或是线材坏掉。
The terminals and wires are
poorly connected or the
wires failed
③、中心板坏。Main PCB failed
①、更换振动电机
Replace the vibration motor
②、将端子接插到位或者更换线材。
Plug the terminal well or
replace the wires
③、更换中心板
Replace main PCB
10
座部不充气
no air in the
seat-pad
11
小腿不充气
no gas charging in
the calves-rest
12
披风不充气
no gas charging in
the manteau of
backrest
①、气泵泄气阀端子接触不良
The terminal of the air discharge
of inflator valves and wires are
poorly connected
②、泄气阀坏
The air discharge of inflator
valves failed
③ 、 气 泵 坏 The inflator pump
failed
④、中心板坏 Main PCB failed
①、将端子接好
Plug the terminal well
②、更换泄气阀。
Replace the air discharge of
inflator valves
③、更换气泵。
Replace the inflator pump
④、更换中心板
Replace the main PCB
13
小腿不伸缩
no extending
or shrinking of the
calves-rest
①、端子接触不良
The terminals and wires are
poorly connected
②、检查端子是否有 24V 输出
The output voltage is not 24VAC
③、检查光耦是否有问题
The optocouplers failed
④、电机不良 The motor failed
①、将端子接好。
Plug the terminal well
②、无输出为中心板坏
Replace the main PCB if no
voltage output
③、有更换光电组件
Replace the optocouplers
④、更换电机
Replace the motor