![EASEPAL EC-385A Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/easepal/ec-385a/ec-385a_maintenance-service-manual_522040011.webp)
8、振动电机不工作
No vibration
9、座部/腿部/靠背披风/肩部不充气
No gas charging
(
Seat pad / Calves-rest/Backrest part/should massage
)
检查振动电机连接线与中心板是否连接好
The terminals of their print motors with main
PCB connected securely?
检查座部振动电机对插线是否连接好
Check the connectors in the middle of the wire
connected securely?
更换中心板
Replace the main PCB
将连接线接好
Touch well
检查振动电机是否损坏
Check the print motor
更换振动电机
Replace print motor
检查座部泄气阀连接线是否与中心板连接好
Check the terminals of snuffle valve for bags with main
PCB connected securely?
检查泄气阀是否损坏
Check the snuffle valve
将连接线接好
Touch well
检查气泵连接线是否与中心板连接好
Check the terminals of inflator pump with main
PCB connected securely?
更换泄气阀
Replce snuffle valve
将连接线接好
Touch well
将连接线接好
Touch well
NG
OK
OK
OK
NG
NG
NG
OK
OK
NG
NG
OK