DISCLAIMER: THIS DOCUMENT IS A DRAFT, AND PROVIDED AS A COURTESY. PLEASE DO NOT SHARE.
Equalizer Kit contains
Equalizer Kit
Eastron SDM630MCT-RC 3-phase
meter reader
Measurements (mm): H: 94,5 x W: 72 x D: 65
Voltage: 3 x 400V ac / 230V ac
Network frequency: 50/60Hz (± 2%)
Type: 3-phase 400 imp/kWh
IP-classification: IP51
Running temperature: -25°C - 55°C
Primary connection: 2,5mm2
Secondary connection: 2,5mm2
Montage: DIN-rail or alternative wall mount
with screw
Material: Self-extinguishing UI94 V-0
Tufvassons electricity transformer
Measurements (mm): H: 110 x W: 53 x D: 66
Input voltage: 180-264V, 47-63 Hz N - L
Output voltage: 24V dc (± 5%)
Effect: 30VA (1,25A) (electricity limit 2,5A)
MTBP: 50000 h at 70% load at 25°C
IP-classification: IP40
Running temperature: -10°C - 45°C
Double isolation (not to be earthed)
Protected against circuit cut and overload
Primary connection: 2-polig 2,5mm2
Secondary connection: 2-polig 2,5mm2
Mounting: DIN-rail or wall mount with screw
100A Kit
CT Clamps (3 pcs)
Input: Max 100A
Output: 333 mV
Measurements (mm): H: 46 W: 29
Diameter: 15.7 mm
Running temperature: -15°C - +60°C
RJ12 cable
Length: 1.5m
Colour: Black
Pre-cut
Connector plug: RJ12
Lead cable: 6 pin
Kit variant contains
500A Kit
Rogowski Coils (3pcs)
Input: 500A
Output: 85-100 mV | 1KA
Measurements (mm): L: 200
Diameter: 45-60 mm
Running temperature: -30°C - +80°C