Cooling mode:
Information requirements for air-to-air conditioners
Power consumption in modes other than "active mode"
Other items
Model(s):
EVRO-140NDC
Test matching indoor units from2,non-duct:2×MI-36Q4* + 2×MI-28Q4*
Outdoor side heat exchanger of air conditioner:air
Indoor side heat exchanger of air conditioner:air
Type:compressor driven
If applicable:driver of compressor:electric motor
Tj=+35
℃
Tj=+30
℃
Tj=+25
℃
Tj=+20
℃
Tj=+35
℃
Tj=+30
℃
Tj=+25
℃
Tj=+20
℃
EER
d
EER
d
EER
d
EER
d
2.87
4.69
7.53
10.19
-
-
-
-
14.000
10.016
6.629
5.176
kW
kW
kW
kW
Item
Symbol
Value
Unit
Item
Rated cooling
capacity
Degradation co-efficient
for air conditioners(*)
Declared cooling capacity for part load at given outdoor
temperatures Tj and indoor 27/19
℃
(
dry/wet bulb
)
Declared energy efficiency ratio or gas utilisation efficiency/auxiliary
energy factor for part load at given outdoor temperatures Tj
P
rated,c
P
dc
P
dc
P
dc
P
dc
C
dc
0.25
-
14
kW
Seasonal space cooling
energy efficiency
η
s,c
233.8
%
Symbol
Value
Unit
Off mode
Thermosat-off
mode
Crankcase heater
mode
Standby mode
0.023
0.023
kW
kW
0.023
0
kW
kW
P
OFF
P
CK
P
SB
P
TO
Capacity control
Contact details
(*)If C
dc
is not determined by measurement then the default degradation coefficient of heat pumps shall be 0.25
Where information relates to multi-split air conditioners,the test result and performance data may be obtained on the basis of
performance of the outdoor unit ,with a combination of indoor unit(s) recommended by the manufacturer or importer
Sound power
level,outdoor
GWP of the
refrigerant
For air-to-air air
conditioner:air
flow rate,outdoor
measured
6500
-
m
3
/h
variable
73
2088
dB
kg CO
2
eq
(100years)
L
WA
V.2