71
Item
Symbol
Value
Unit
Item
Symbol
Value
Unit
Rated heat output (*)
Prated
11
kW
Seasonal space heating
energy efficiency
ηs
129
%
Tj = -7
℃
Pdh
10.0
kW
Tj = -7
℃
COPd
2.01
-
Tj = 2
℃
Pdh
6.3
kW
Tj = 2
℃
COPd
3.18
-
Tj = 7
℃
Pdh
4.0
kW
Tj = 7
℃
COPd
4.54
-
Tj = 12
℃
Pdh
2.6
kW
Tj = 12
℃
COPd
5.37
-
Tj = bivalent temperature
Pdh
10.0
kW
Tj = bivalent temperature
COPd
2.01
-
Tj = operating limit
Pdh
10.9
kW
Tj = operating limit
COPd
1.76
-
For air-to-water heat pumps:
Tj = -15
℃
Pdh
-
kW
For air-to-water heat pumps:
Tj = -15
℃
COPd
-
-
Bivalent temperature
T
biv
-7
°C
For air-to-water heat pumps:
Operation limit temperature
TOL
-10
°C
Cycling interval capacity for
heating
P
cych
-
kW
Cycling interval efficiency
COP
cyc
or
PERcyc
-
%
Degradation co-efficient (**)
C
dh
0.9
--
Heating water operating limit
temperature
W
TOL
49
°C
off mode
P
off
0.017
kW
standby mode
P
sb
0.017
kW
thermostat-off mode
P
to
0.006
kW
crankcase heater mode
P
ck
0.018
kW
Sound power level, indoors/
outdoors
L
WA
-/66
dB
Annual energy consumption
Q
HE
7025
kWh
or GJ
Declared load profile
Water heating energy
efficiency
η
wh
-
%
Daily electricity consumption
Q
elec
-
kWh
Daily fuel consumption
Q
fuel
-
kWh
Annual electricity consumption
AEC
-
kWh
Annual fuel consumption
AFC
-
GJ
Contact details
Electrical Heating
Rated heat output (**)
0.4
Psup
kW
For water- or brine-to-water
heat pumps: Rated brine or
water flow rate, outdoor heat
exchanger
_
-
m
3
/h
_
Heat pump combination heater:
Type of energy input
Technical parameters
variable
Capacity control
ETH-110VM
YES
NO
NO
NO
YES
NO
Model(s):
Water-to-water heat pump:
Brine-to-water heat pump:
Low-temperature heat pump:
(*) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating Pdesignh,
and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj).
(**) If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low-temperature heat pumps, parameters
shall be declared for low-temperature application.
Air-to-water heat pump:
Declared capacity for heating for part load at indoor temperature 20 °C
and outdoor temperature Tj
Declared coefficient of performance or primary energy ratio for part load at
indoor temperature 20 °C and outdoor temperature Tj
Power consumption in modes other than active mode
Supplementary heater
-
For heat pump combination heater:
For air-to-water heat pumps:
Rated air flow rate, outdoors
Parameters shall be declared for average, colder and warmer climate conditions
Other items
6150
m³/h
Equipped with a supplementary heater:
V.2
EAS ELECTRIC
Pol. Industrial San Carlos, Parcela 13 03370 Redován (Alicante)
www.easelectric.es
Содержание ETH-80VM
Страница 4: ...4 1 2 1 3 1 1 1 1 1 1 1 2 3 1 1 0 1 0 1 0 Forma Nombre V 2...
Страница 7: ...NOTA NOTA NOTA 404 502 1210 361 760 1404 760 361 1404 100mm 80mm 7 kW 10 12 14 16 kW 7 V 2...
Страница 49: ...50 11 PRUEBA DE FUNCIONAMIENTO Y COMPROBACI N FINAL V 2...
Страница 50: ...51 NOTA V 2...
Страница 56: ...57 Equipos Monof sicos 5 y 7kW ANEXO 1 ESQUEMA EL CTRICO UNIDAD INTERIOR V 2...
Страница 57: ...58 Equipos Monof sicos 10 a 16kW V 2...
Страница 62: ...CONTROL POR CABLE CON PROGRAMACI N SEMANAL MANUAL DE INSTALACI N Y MANUAL DE USUARIO MODELO ECRTH V 2...
Страница 86: ...60mm B C A 25 V 2...
Страница 176: ...V 2 WIRE CONTROL WITH WEEKLY PROGRAMMING OWNER S MANUAL MODEL ECRTH...