Adapting to the different types of gas
Changing the nozzles
5) Then replace the setting data (close to the mains gas
connection) with the one for the new type of gas If the pressure of
the gas used is different from that specified(or variable),a suitable
piped gas pressure regulator complying with the standard must be
installed on the supply pipeline.
Setting the minimum level
1)
Light the burner as already described.
2)
Turn the tap to the minimum flame position.
3)
Remove the control knobs.
4) LPG TO NG:
Use a thin blade screwdriver to turn the by-pass
screw located above left of the gas valve, shaft as
shown right.
5
)
Turn
gently the by-pass screw clockwise to the end completely
then turn it anti-clockwise 1/2 turn for the Triple flame burner,
3/4 turn for the Large rapid burner, 1/2 turn for the Medium
Semi-rapid Burner
and 3/8 turn for the Auxiliary burner.
NG TO LPG:
Use a thin blade screwdriver to turn the by-pass screw located
above left of the gas valve shaft as shown right. Turn gently the
by-pass screw clockwise to the end.
Finally, check that the burner does not go out when the tap is
turned quickly from the maximum to the minimum position.
1)
Remove the pan standee.
2)
Remove the burner caps and flame caps from
the burners.
3)
Use a size 7 socket wrench to unscrew and
remove the
nozzles, replacing them with
those corresponding to the
type of gas to be
used (see the table
).
4)
Reassemble the parts, reversing the
operations described
above.