Step 10:
Attach the
linkage pivot
with
¼”
-
20 x 1 ½”
bolt, MD flat
washer
, black
spacer
, and
lock nut
(shown above).
Step 11:
Turn the end of the control rod into the keyed shut-off plate under the hopper.
Step 12:
Install the
½”
carriage bolt
through the
control rod
and install the SM
flat washer
and
hex
nut
on the
carriage bolt. Allow a loose fit for CALIBRATION instructions below.
CALIBRATION
Pull the Control Lever back to #30 on the Gauge,
then push the shut-off plate forward until the
shut-off and the drop holes are fully open. Now
tighten the
Hex Nut
on the
½”
carriage
bolt
on
the
linkage
assembly
. Check to confirm
calibration by closing the control lever, then
reopening to #30 and confirm that the drop holes
are fully open.
Step 13:
Insert agitator to pinion shaft on
inside of hopper.
Note
: The position of flat side of the agitator.
This pin should be installed as shown.