background image

Assembly and Operation Instructions 

 

2600A-PLUS_M52215_July2021

 

PAGE 4 

PAGE  

 

 

Step 10: 

Attach the 

linkage pivot 

with 

¼”

-

20 x 1 ½”

 bolt, MD flat 

washer

, black 

spacer

, and 

lock nut

 (shown above). 

Step 11: 

Turn the end of the control rod into the keyed shut-off plate under the hopper. 

Step 12: 

Install the 

½” 

carriage bolt

 through the 

control rod 

and install the SM 

flat washer

 and 

hex

 

nut

 on the 

carriage bolt. Allow a loose fit for CALIBRATION instructions below. 

CALIBRATION 

Pull the Control Lever back to #30 on the Gauge, 
then push the shut-off plate forward until the 
shut-off and the drop holes are fully open.  Now 
tighten the 

Hex Nut

 on the 

½”

 

carriage

 

bolt

 on 

the 

linkage

 

assembly

.  Check to confirm 

calibration by closing the control lever, then 
reopening to #30 and confirm that the drop holes 
are fully open. 

 

Step 13: 

Insert agitator to pinion shaft on 

inside of hopper. 

Note

: The position of flat side of the agitator. 

This pin should be installed as shown. 

 

 

 
 
 
 