EARTHSTONE OVENS PRE-ASSEMBLED GAS OVEN INSTALLATION INSTRUCTIONS 

 

      

       3 

 
 

GAS ISTALLATIO 

 

 

THE OVEN SHOULD BE CONNECTED ONLY TO THE TYPE OF GAS FOR WHICH IT IS EQUIPPED. 
 
ALL PIPES AND JOINTS MUST BE TESTED FOR LEAKS WITH A SOAP AND WATER SOLUTION BEFORE OPERATING 
THE OVEN.  DO NOT USE AN OPEN FLAME TO CHECK FOR LEAKS. 
 
A 1/8 PRESSURE TAP IS LOCATED ON THE COMBUSTION GAS CONTROL TO CHECK THE MANIFOLD PRESSURE.  
REFER TO NAMEPLATE FOR PROPER SETTING.  THE CONTROL IS PRESET AT THE FACTORY PRIOR TO SHIPPING. 
 
CONNECT GAS SUPPLY (3/4 INCH) TO OVEN.  USE PIPE JOINT COMPOUND THAT IS NON REACTIVE TO LP GAS ON 
ALL THREADED JOINTS.  CHECK FOR GAS LEAKS WITH SOAPY WATER SOLUTION. 
 

OTE:  IT IS RECOMMEDED THAT A SERVICE SHUTOFF VALVE BE PROVIDED 

 OUTSIDE THE OVE AT THE TIME OF ISTALLATIO 

 

CONNECT OVEN TO A 120 VAC, 60HZ, 2.5 AMP  1 PH POWER SUPPLY.  MAKE SURE THAT SYSTEM IS PROPERLY 

GROUNDED.

 

 

OPERATIO 

 
READ ALL INSTRUCTIONS CAREFULLY. IMPROPER USE OF THIS APPLIANCE MAY RESULT IN A BUILDING FIRE OR 
PERSONAL INJURY.  INSTRUCTIONS MUST BE READ AND THOROUGHLY UNDERSTOOD BY ALL OPERATING AND 
SUPERVISING PERSONNEL.  WATCH TRAINING VIDEO FOR VISUAL OPERATION INSTRUCTIONS. 
 
THIS OVEN IS INTENDED FOR ATTENDED OPERATION BY TRAINED AND QUALIFIED PERSONNEL ONLY. 
 
THIS OVEN IS A HEAT PRODUCING APPLIANCE AND MAY CAUSE SEVERE BURNS IF TOUCHED. 
 
THIS UNIT IS DESIGNED AS A GAS-FIRED OR GAS/WOOD FIRED OVEN. DIRECT FOOD CONTACT WITH HEARTH IS 
RESTRICTED TO PIZZAS AND BREAD PRODUCTS ONLY.  FOR OTHER FOODS REFER TO MANUFACTURE 
OPERATION GUIDELINES. 
 

OVE DOOR MUST BE REMOVED BEFORE OPERATIG OVE.

 

 

FIRIG OVE

 

 
BEFORE STARTING, TURN ON EXHAUST AND MAKE-UP AIR BLOWERS. 
 
TURN ON SERVICE SHUT-OFF VALVE. 
 
TURN ON KNOB OF COMBINATION GAS CONTROL. 
 
SET THERMOSTAT TO DESIRED TEMPERATURE SETTING (600 TO 750) 
 
TURN ON ELECTRICAL SWITCH. A SPARK IS GENERATED WHICH WILL IGNITE THE GAS AT THE MAIN BURNER. 

 
SHUTTIG DOW OVE. 
 

FOR TEMPORARY  SHUT DOWN TURN OFF ELECTRICAL SWITCH. 
 
FOR COMPLETE SHUT DOWN TURN KNOB OF COMBUSTION GAS CONTROL TO OFF. 
 
 

Содержание GAS FIRED OVEN

Страница 1: ...ROMINENT LOCATION FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE LIQUIDS OR VAPORS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WAR I G IMPROPER INSTALLATION ADJUSTMENT ALTERATION S...

Страница 2: ...GRAM IS LOCATED ON THE CONTROL BOX INSTALLATION MUST CONFORM WITH LOCAL CODES OR IN THE ABSENCE OF LOCAL CODES WITH THE NATIONAL FUEL GAS CODE ANSI Z223 1 THE NATURAL GAS INSTALLATION CODE CAN CGA B14...

Страница 3: ...STRUCTIONS CAREFULLY IMPROPER USE OF THIS APPLIANCE MAY RESULT IN A BUILDING FIRE OR PERSONAL INJURY INSTRUCTIONS MUST BE READ AND THOROUGHLY UNDERSTOOD BY ALL OPERATING AND SUPERVISING PERSONNEL WATC...

Страница 4: ...TE SIDE OF THE GAS BURNER SEE DIAGRAM WOOD SHOULD BE USED ONLY FOR FLAVORING AND AESTHETIC VALUE THE MAIN SOURCE OF HEAT SHOULD BE SUPPLIED BY THE GAS BURNER KEEP A PROPER FIRE EXTINGUISHER CLOSE TO T...

Страница 5: ...d container closed at all times when not adding or removing firewood Keep container a considerable distance from the oven and far away from sources of heat or ignition DO NOT store matches paper or ot...

Страница 6: ...ced chimney and duct servicing personnel who are qualified in the removal of both creosote and grease from flues and ducts should be contracted to do the inspection and cleaning The inspection and cle...

Страница 7: ...URNER FOR CLEANING FOLLOW THESE STEPS DISCONNECT CABLE FROM SPARK IGNITER UNSCREW FITTING OF GAS SUPPLY LINE WHICH IS NEAREST TO BURNER ASSEMBLY THIS SUPPLY LINE CONNECTS THE GAS VALVE TO BURNER ASSEM...

Страница 8: ...OR COUNTER CLOCKWISE 5 RED BUTTO USED SIMULTANEOUSLY WITH BLACK DIAL KNOB TO SET TEMPERATURE SEE PAGE LABELED SWITCH DIAGRAM LAYOUT OPERATION FIRI G OVE OTE DO OT CLOSE DOOR WHILE OVE IS BEI G FIRED...

Страница 9: ...USE ANY CLEANING AGENTS IN THE OVEN SHUTTI G DOW OVE TURN MAIN POWER SWITCH TO OFF POSITION IF OVEN IS BEING SHUT DOWN FOR THE NIGHT GAS CONTROL VALVE SHOULD BE TURNED TO OFF POSITION SAVE THESE I STR...

Страница 10: ...EARTHSTONE OVENS PRE ASSEMBLED GAS OVEN INSTALLATION INSTRUCTIONS 10 GAS BURNER CONTROLS E S ARTH TONE LOS ANGELES OFF ON HI LO HI OFF 000 1 2 3 4 5...

Страница 11: ...en may cause negative pressure servicing proper operation If this area is to be covered with a facade it must be of a non combustable material Temperature gauge and On off switch can be extended to at...

Страница 12: ...STALLATION INSTRUCTIONS 12 GAS BURNER WOOD All wood fired in a gas wood combination o ven should be located on the opposite side of the gas bu rner Take caution to avoid ashes from entering the gas bu...

Страница 13: ...EARTHSTONE OVENS PRE ASSEMBLED GAS OVEN INSTALLATION INSTRUCTIONS 13 LOG CONFIGURATION TOP VIEW SIDE VIEW LOG 1 1 LOG HAS A NOTCH TO SUPPORT LOG FROM ROLLING OFF LOWER SUPPORT LOG...

Страница 14: ...opening needed for combustion air Only one intake should be installed located in the front or back of oven Gas Burner system Air flow Roof False Ceiling Air flow Air flow 24 x24 opening needed for co...

Страница 15: ...sure below where the gas burner is located The air underneath will travel towards the air flow above creating a suction which will force the gas flame downwards To prevent this a non combustable lid m...

Страница 16: ...ER CLOCKWISE TO DECREASE AND CLOCKWISE TO INCREASE REMOVE OVE DOOR THE DOOR SHOULD OT BE CLOSED WHE OVE IS FIRED WITH A 2 SIDED OVE YOU CA HAVE O E DOOR CLOSED MOVE HI LO HI OFF SWITCH TO HI LO UPWARD...

Страница 17: ...d Pressure The amounts listed below are set at the factory Natural Gas Manifold pressure 90 PAGW 4 W C 110 PAGW 4 W C 130 PAGW 4 5 W C 160 PAGW 4 5 W C LP Gas Manifold pressure 90 PAGW 7 W C 110 PAGW...

Отзывы: