EARTHSTONE OVENS PRE-ASSEMBLED GAS OVEN INSTALLATION INSTRUCTIONS 

 

      

       4 

 

 

WOOD AD/OR GAS FIRED COMBIATIO PIZZA OVE 

OPERATIG ISTRUCTIOS 

 

WARNING

 
READ ALL INSTRUCTIONS CAREFULLY.  IMPROPER USE OF THIS APPLIANCE MAY RESULT IN A BUILDING FIRE 
OR PERSONAL INJURY.  INSTRUCTIONS MUST BE READ AND THOROUGHLY UNDERSTOOD BY ALL OPERATING 
AND SUPERVISING PERSONNEL.  WATCH TRAINING VIDEO FOR VISUAL OPERATION INSTRUCTIONS. 
 
THIS OVEN IS INTENDED FOR ATTENDED OPERATION BY TRAINED AND QUALIFIED PERSONNEL ONLY. 
 
THIS OVEN IS A HEAT PRODUCING APPLIANCE AND MAY CAUSE SEVERE BURNS IF TOUCHED. 
 

 

 
DO  NOT  OVER  FIRE.    IF  FLAME  SPILLS  FROM  THE  DOOR  OPENING  OR  OVEN  TEMPERATURE  EXCEEDS  1000 
DEGREES FAHRENHEIT, YOU ARE OVER FIRING. 
 
THIS UNIT IS DESIGNED AS A GAS OR GAS/WOOD FIRED OVEN. DIRECT FOOD CONTACT WITH THE HEARTH IS 
RESTRICTED  TO  PIZZAS  AND  BREAD  PRODUCTS  ONLY.    FOR  OTHER  FOODS  REFER  TO  MANUFACTURE 
OPERATION  GUIDELINES.   

ALL  WOOD  EMBERS  BURNED  INSIDE  THE  OVEN  MUST  BE  PLACED  DIRECTLY  ON 

THE OPPOSITE SIDE OF THE GAS BURNER (SEE DIAGRAM).  WOOD SHOULD BE USED ONLY FOR FLAVORING 
AND AESTHETIC VALUE, THE MAIN SOURCE OF HEAT SHOULD BE SUPPLIED BY THE GAS BURNER 

 
KEEP A PROPER FIRE EXTINGUISHER CLOSE TO THE OVEN AT ALL TIMES.  EXTINGUISHER MUST BE RATED 
FOR  USE  ON  WOOD  FIRES.    INSTRUCT  ALL  PERSONNEL  ABOUT  LOCATION  AND  USE  OF  THE  FIRE 
EXTINGUISHER AND PROPER FIRE EMERGENCY PROCEDURES. 
 
a- 

Before starting, turn "ON" exhaust fan and make-up air blowers. 

 
b- 

Place a small amount of wood and kindling on the hearth over a fire-starter block.  Light fire- 

 

 

starter.  At any time do not use more than four pieces of wood, 

 
c- 

CAUTION:  NEVER USE GASOLINE TYPE LANTERN FUEL, KEROSENE, CHARCOAL   

 

LIGHTER FLUID OR SIMILAR PRODUCTS TO START OR "FRESHEN UP" A FIRE IN THIS  

 

 

OVEN. KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE OVEN WHEN IN USE. 

 

d.

 

When the kindling is burning well, add larger pieces of firewood.  USE WELL-SEASONED OR  

 

DRIED WOOD ONLY. 

 
e- 

Continue to add fuel as needed to maintain the desired heated rate, being careful to never  

 

 

over fire the unit. 

 
f- 

Whenever fuel is added, the fire may be poked and stirred with a wood handling tool.  This will  

 

 

allow air to move through the fuel bed for proper combustion. 

 
 

Содержание GAS FIRED OVEN

Страница 1: ...ROMINENT LOCATION FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE LIQUIDS OR VAPORS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WAR I G IMPROPER INSTALLATION ADJUSTMENT ALTERATION S...

Страница 2: ...GRAM IS LOCATED ON THE CONTROL BOX INSTALLATION MUST CONFORM WITH LOCAL CODES OR IN THE ABSENCE OF LOCAL CODES WITH THE NATIONAL FUEL GAS CODE ANSI Z223 1 THE NATURAL GAS INSTALLATION CODE CAN CGA B14...

Страница 3: ...STRUCTIONS CAREFULLY IMPROPER USE OF THIS APPLIANCE MAY RESULT IN A BUILDING FIRE OR PERSONAL INJURY INSTRUCTIONS MUST BE READ AND THOROUGHLY UNDERSTOOD BY ALL OPERATING AND SUPERVISING PERSONNEL WATC...

Страница 4: ...TE SIDE OF THE GAS BURNER SEE DIAGRAM WOOD SHOULD BE USED ONLY FOR FLAVORING AND AESTHETIC VALUE THE MAIN SOURCE OF HEAT SHOULD BE SUPPLIED BY THE GAS BURNER KEEP A PROPER FIRE EXTINGUISHER CLOSE TO T...

Страница 5: ...d container closed at all times when not adding or removing firewood Keep container a considerable distance from the oven and far away from sources of heat or ignition DO NOT store matches paper or ot...

Страница 6: ...ced chimney and duct servicing personnel who are qualified in the removal of both creosote and grease from flues and ducts should be contracted to do the inspection and cleaning The inspection and cle...

Страница 7: ...URNER FOR CLEANING FOLLOW THESE STEPS DISCONNECT CABLE FROM SPARK IGNITER UNSCREW FITTING OF GAS SUPPLY LINE WHICH IS NEAREST TO BURNER ASSEMBLY THIS SUPPLY LINE CONNECTS THE GAS VALVE TO BURNER ASSEM...

Страница 8: ...OR COUNTER CLOCKWISE 5 RED BUTTO USED SIMULTANEOUSLY WITH BLACK DIAL KNOB TO SET TEMPERATURE SEE PAGE LABELED SWITCH DIAGRAM LAYOUT OPERATION FIRI G OVE OTE DO OT CLOSE DOOR WHILE OVE IS BEI G FIRED...

Страница 9: ...USE ANY CLEANING AGENTS IN THE OVEN SHUTTI G DOW OVE TURN MAIN POWER SWITCH TO OFF POSITION IF OVEN IS BEING SHUT DOWN FOR THE NIGHT GAS CONTROL VALVE SHOULD BE TURNED TO OFF POSITION SAVE THESE I STR...

Страница 10: ...EARTHSTONE OVENS PRE ASSEMBLED GAS OVEN INSTALLATION INSTRUCTIONS 10 GAS BURNER CONTROLS E S ARTH TONE LOS ANGELES OFF ON HI LO HI OFF 000 1 2 3 4 5...

Страница 11: ...en may cause negative pressure servicing proper operation If this area is to be covered with a facade it must be of a non combustable material Temperature gauge and On off switch can be extended to at...

Страница 12: ...STALLATION INSTRUCTIONS 12 GAS BURNER WOOD All wood fired in a gas wood combination o ven should be located on the opposite side of the gas bu rner Take caution to avoid ashes from entering the gas bu...

Страница 13: ...EARTHSTONE OVENS PRE ASSEMBLED GAS OVEN INSTALLATION INSTRUCTIONS 13 LOG CONFIGURATION TOP VIEW SIDE VIEW LOG 1 1 LOG HAS A NOTCH TO SUPPORT LOG FROM ROLLING OFF LOWER SUPPORT LOG...

Страница 14: ...opening needed for combustion air Only one intake should be installed located in the front or back of oven Gas Burner system Air flow Roof False Ceiling Air flow Air flow 24 x24 opening needed for co...

Страница 15: ...sure below where the gas burner is located The air underneath will travel towards the air flow above creating a suction which will force the gas flame downwards To prevent this a non combustable lid m...

Страница 16: ...ER CLOCKWISE TO DECREASE AND CLOCKWISE TO INCREASE REMOVE OVE DOOR THE DOOR SHOULD OT BE CLOSED WHE OVE IS FIRED WITH A 2 SIDED OVE YOU CA HAVE O E DOOR CLOSED MOVE HI LO HI OFF SWITCH TO HI LO UPWARD...

Страница 17: ...d Pressure The amounts listed below are set at the factory Natural Gas Manifold pressure 90 PAGW 4 W C 110 PAGW 4 W C 130 PAGW 4 5 W C 160 PAGW 4 5 W C LP Gas Manifold pressure 90 PAGW 7 W C 110 PAGW...

Отзывы: