background image

EARTHSTONE OVENS PRE-ASSEMBLED INSTALLATION INSTRUCTIONS--- ETL LISTED                                  

4

 

A. 

 

INSTALLATION PROCEDURES

 

 

1. 

Mark an outline on the floor of the location desired.  This is to assure that you have adequate 

 

space.  Refer to Fig. 1, pg. 6. 

 

2. 

Check that there is adequate clearance at the ceiling for the hood.  There must be a minimum of 3 

inches of clearance between the top of the oven and the surface of the drywall above.  (Refer to 

Fig. 2 & 3 pg. 6) 

 

3. 

It  is  recommended  to  use  non  combustible  framing.  If  combustibles  are  near  oven  check  that 

 

there  is  a  minimum  clearance  of  1  inch  to  any  adjacent  sidewall  construction  containing 

 

combustibles.    Any  adjacent  combustible  sidewalls  which  projects  beyond  the  front  of  the  oven 

 

opening must be a minimum of 48 inches, measured from the side of the oven opening closest 

 

to the wall to the surface of the wall.  (Refer to Fig. 4, pg. 6).  If the distance is less than 48 inches 

 

a  wall  shield  must  be  mounted  on  the  wall.  Refer  to  the  U.L.  listed  wall  shield  installation 

 

instructions for the allowable clearance reduction. 

 

 

Any  adjacent  combustible  floor  which  projects  in  front of the oven opening must be a minimum 

 

of  30  inches  away  from  each  side  of  the  door  opening  and  36  inch  from  the  front  of  the  door 

 

opening. 

 

 

WARNING: DO NOT PACK REQUIRED AIR SPACES WITH INSULATION OR OTHER 

MATERIALS

 

 

 

A minimum of 3 inches must be maintained between any combustibles and the top of the 

 

metal covering over the oven enclosure.  Refer to Fig 2 & 3 pg. 6. 

 

4. 

Once the oven is in the desired position, drill holes for the anchor bolts (Min 3 inches deep) using 

the base plates as a guide.  Insert ramset red heads to fasten oven base  plates to concrete floor. 

(Fig 17-A pg. 7) 

 
 

5. 

The  outside  surface  of  the  oven  enclosure  may  be  faced  with  non-combustible  facing 

material if desired.  This might include but not limited to:  Brick, Ceramic tiles, Stainless 
steel,  Marble  or  any  other  decorative  metals.   

DO  NOT  FACE  WITH  COMBUSTIBLE 

MATERIALS  OR  USE  COMBUSTIBLE  ADHESIVES.  Allow  for  access  to  top  of  the 
oven for servicing. 

 

NOTE: FOR HEALTH DEPARTMENT REQUIREMENTS ANY 1-INCH AIR GAP 
ADJACENT  TO  A  COMBUSTIBLE  WALL  MUST  BE  SEALED  WITH  A  NON 
COMBUSTIBLE STRIP.  i.e.  ALUMINUM, STAINLESS STEEL OF TILE. 

 
 

 

B. 

 

VENTING APPLICATION

 

 

A U.L. LISTED GREASE DUCT/BUILDING HEATING APPLIANCE CHIMNEY INSTALLATION (DIRECT 
VENTING).  PLEASE  CONFIRM  WITH  THE  LOCAL  BUILDING  DEPT.  BEFORE  BEGINNING 
INSTALLATION OF THE OVEN.

 

IT IS NEVER APPROPRIATE TO USE “CLASS A” OR “B VENT” IN ANY 

PART  OF  THE  EXHAUST  SYSTEM.    EXHAUST  SYSTEMS  SERVING  SOLID-FUEL  EQUIPMENT  MAY 
NOT  BE  COMBINED  WITH  EXHAUST  SYSTEMS  SERVING  OTHER  (NON-SOLID  FUEL)  COOKING 
EQUIPMENT

 

 

 
Important:  Chases should be made of non-combustible materials. 

 

 

 

Содержание 90-PAGW

Страница 1: ...1 TELEPHONE 800 840 4915 818 553 1134 FAX 818 553 1133 www earthstoneovens com e mail info earthstoneovens com A MAJOR CAUSE OF OVEN RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES AIR SPACES...

Страница 2: ...Table of contents Page Instructions for moving and lifting oven NEXT PAGE Parts list 1 Installation procedures written portion 2 5 Required clearances and air gaps 6 Exhausting 4 6 8 Operating instru...

Страница 3: ...y place forks through inside of tube steel supports legs and position under horizontal tube steel members Slowly lift and move oven as needed See dia A 2 USING A PALLET JACK Determine if pallet jack c...

Страница 4: ...MBLED INSTALLATION INSTRUCTIONS ETL LISTED 1 LIST OF SUPPLIED ITEMS OVEN ADDITIONAL ITEMS CAST ALUMINUM DOOR DIAL TEMPERATURE GAUGE FOR WOOD FIRE OVENS DIGITAL THERMOMETER FOR GAS FIRE OVENS REQUIRES...

Страница 5: ...uct In most areas this will include a permit to construct the oven and a permit for the exhaust system Sometimes an electrical permit is also necessary for connecting the exhaust fan All construction...

Страница 6: ...act with hearth is restricted to pizzas and bread products only Refer to manufacture for other foods 3 The manual recommends the use of untreated wood only no more than four pieces at a time 4 Burn in...

Страница 7: ...ing WARNING DO NOT PACK REQUIRED AIR SPACES WITH INSULATION OR OTHER MATERIALS A minimum of 3 inches must be maintained between any combustibles and the top of the metal covering over the oven enclosu...

Страница 8: ...ored in the same room as the oven Refer to NFPA 96 for wood storage requirements OVEN CURING PA PAG and PAGW ovens are pre cured however the first two fires should be small in order to properly cure t...

Страница 9: ...E DIAMETER MODEL 60 33 X 32 MODEL 90 50 MODEL 110 58 MODEL 130 70 MODEL 160 86 ALL CLEARANCES SPECIFIEDARE THE MINIMUM REQUIRED AIR SPACES WARNING DO NOT PACK REQUIRED AIR SPACES WITH INSULATION OR OT...

Страница 10: ...EARTHSTONE OVENS PRE ASSEMBLED INSTALLATION INSTRUCTIONS ETL LISTED 7 4 to 6 conc Floor slab Embed 4 min Oven stand Base plate Dia Anchors Coat with Simpson s epoxy FIGURE 17 A...

Страница 11: ...CTIONS CONTACT LOCALAU THORITY HAVING JURISD ICTI ON REGARDING FIRE RATED DUCT SHAFT NOTE OTHER U L LISTED SYSTEMS MAY BE SUBSTITUTED FOR THE METALBESTOS SYSTEM DEPICTED IN T HIS DIAGRAM TO MAINTAIN T...

Страница 12: ...OKE SPILLAGE WHEN REMOVING DOOR FROM IN FRONT OF DOOR OPENING SLIDE DOOR OUT 2 3 INCHES FROM OPENING AND THEN WAIT 15 SECONDS BEFORE REMOVING DOOR COMPLETELY FLARE UPS CAN OCCUR WHEN DOOR IS OPENED SU...

Страница 13: ...e being set into the oven h When finished cooking spread remaining embers on the floor of the oven hearth Close door against door opening This will clean the oven floor 9 CAUTION Many structure fires...

Страница 14: ...emoval of both creosote and grease from flues and ducts should be contracted to do the inspection and cleaning The inspection and cleaning schedule must be adjusted as needed to prevent the buildup of...

Страница 15: ...ven may cause negative pressure servicing proper operation If this area is to be covered with a facade it must be of a non combustable material Temperature gauge and On off switch can be extended to a...

Страница 16: ...on Proper installation Roof False Ceiling Air flow Air flow 24 x24 opening needed for combustion air Only one intake should be installed located in the front or back of oven Gas Burner system Air flow...

Страница 17: ...ressure below where the gas burner islocated The air underneathwill travel towards the air flow above creating a suction which will force the gas flame downwards To prevent this a non combustable lid...

Страница 18: ...ISTED 15 Expansion cracks due to the refractory mass are normal in the front entrance and on any interior surface This will not effect the performance efficiency and longevity of the oven in any way N...

Страница 19: ...ll fires One fire each day for one hour for a total of two days You can also do one fire in the morning and one in the late evening When curing each of the fires should lightly touch the dome of the o...

Страница 20: ...is due to the moisture in the stone If you still see moisture from the oven you may need to cure the oven for a few more days Improper curing may cause small pieces of the oven to pop Although this is...

Страница 21: ...2 to 3 hours Model 130 5 6 hours Model 160 6 8 hours Larger ovens models 130 160 used in restaurants will heat much faster after the first initial heat up The large mass needs at least 2 3 days of fir...

Отзывы: