Earthcore Industries
12/2021
Isokern Maximus Linear Series Open Front Gas Fireplace
65
Troubleshooting
Earthcore Industries Technical Support: 1-800-642-2920
Issue
Probable
Cause
Possible Solution
Mechanical draft system
inoperable
No power
- Verify power at the switch
- Verify wiring connections
- Verify “POWER” LED on ADC100 is illuminated
- Refer to Enervex mechanical draft system installation
manuals for detailed troubleshooting
Draft system component alarm /
failure
Consult Enervex manual for detailed draft system
troubleshooting
No spark on pilot
No power
- Verify power is ON
- Check wiring on ignition module, ADC 100, and gas
valve are correct
Ignitor misalignment
-Verify ignitor not contacting pilot gas hood
Loose pilot connections
- - Check pilot wiring assembly is tightly secured to
ignition module
Mechanical draft system
error
- Refer to Enervex mechanical draft system
installation manuals for detailed troubleshooting
Pilot won't ignite
No spark
- See "No spark on pilot"
Air in pilot gas line
- It may take a few minutes to purge out all the air
from the pilot gas tube to ignite
No gas
-
Verify pilot gas tube is threaded sufficiently to gas
valve
-
Verify all gas connections going to and from gas
valve are tight
-
Verify main gas-shutoff valve is in ON position
Pilot won't stay ignited
Flame sensor obstruction
- Remove any obstruction near pilot igniter and
flame sensor
Loose pilot connections
- Check pilot wiring assembly is tightly secured to
ignition module
Low gas pressure
- Verify adequate gas supply pressure
Remote won't
work/unresponsive
Range
- Remote is too far from receiver
Batteries need replacement
- Replace batteries on remote transmitter
Program remote to receiver
- Sync remote transmitter to ignition module; Page 61
Main burner won’t ignite
Pilot won’t ignite
- See "Pilot won't ignite"
Pilot flame won’t stay ignited
- See "Pilot won't stay ignited"
Loose burner segments
- Verify burner segments are tight and secure
Orifice blockage
- Remove burner top pan tray and visually inspect
orifice gas block
Defective valve/ignition module - Replace gas valve or ignition module