background image

1

REV 0 - 1706060745

L-A2-420

EARTHCORE INDUSTRIES, LLC.

  •  6899 Phillips Industrial Blvd  •  Jacksonville, FL 32256

The ISOFLAMES burner system is to be installed only 
in a solid-fuel burning fi replace with a working fl ue and 
constructed of noncombustible material. The installation, 
including provisions for combustion and  ventilation air 
must conform with the 

National Fuel Gas Code, ANSI 

Z223.1/NFPA 54,

 or the 

CSA B149.1, Natural Gas 

and Propane Installation Code

, and applicable local 

building codes.

A damper clamp is included to maintain the minimum 
permanent vent opening and to prevent full closure 
of the damper blade. 

The chimney damper MUST 

be fully opened when burning the unit. The unit is 
designed to burn with yellow fl ames; thus adequate 
ventilation is absolutely necessary.

To comply with certification, listings, and building 
code acceptances, and for safe operation and 
proper performance of this burner system, use ONLY 
ISOFLAMES parts and accessories. Use of other 
controls, parts, and accessories that are not designed 
for use with ISOFLAMES burner systems is prohibited 
and will void all warranties, certifi cations, listings, and 
building code approvals, and may cause property 
damage, personal injury, or loss of life. Earthcore will 
not be liable for any damages caused by this misuse.

*Note:

  Solid-fuels shall not be burned in a fi replace 

where a decorative appliance is installed.

FOR INSTALLATION IN

SOLID-FUEL BURNING 

FIREPLACES*

IMPORTANT:  READ THESE  INSTRUCTIONS 

CAREFULLY BEFORE STARTING 
INSTALLATION OF THE UNIT.

Do not store or use gasoline or other 
flammable vapors and liquids in the 
vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS:

 •  Open a window.

 •  Do not try to light any appliance.

 •  Do not touch any electrical switch; do 

not use any phone in the building.

 •  Immediately call the gas supplier 

from a neighbor’s phone. Follow gas 
supplier’s instructions.

 •  If you cannot reach the gas supplier, 

call the fi re department.

WARNING

If the information in this manual is not 
followed exactly, a fire or explosion 
may result, causing property damage, 
personal injury, or loss of life.

This appliance is only for use with the type 
of gas indicated on the rating plate. 

Installation and service must be performed 
by a qualified professional installer, 
service agency, or the gas supplier.

DESIGN CERTIFIED

to

Vented Decorative Appliance

ANSI Z21.60-2012

CSA 2.26-2012

12-086

INSTALLER:

Leave this manual with the appliance.

CONSUMER:

Retain this manual for future reference

.

STADIUM BURNER VENTED SYSTEMS

Regulated burner 

system for use with 

propane or natural gas

INSTALLATION & 

OWNER’S MANUAL

Burner Systems:

ISF-SBVT24/30VE(N,P)
ISF-SBVT36/39VE(N,P)

Содержание ISF-SBVT24VE(N,P)

Страница 1: ...e will not be liable for any damages caused by this misuse Note Solid fuels shall not be burned in a fireplace where a decorative appliance is installed FOR INSTALLATION IN SOLID FUEL BURNING FIREPLAC...

Страница 2: ...es pertes humaines Earthcore ne sera pas responsable des dommages caus s par ce d tournement Note des Plein carburants ne seront pas br l s dans une chemin e o un appareil d coratif est install POUR L...

Страница 3: ...TEST 13 LOG SET PLACEMENT 14 INSTALLING REPLACING BATTERIES 15 REMOTE TRANSMITTER BATTERY 15 SWITCH BOX BATTERIES 15 NOTES PAGE 16 USE CARE SERVICE LIGHTING INSTRUCTIONS 17 FOR YOUR SAFETY READ BEFORE...

Страница 4: ...st plus longue que 20 une ligne de plus grand diam tre peut tre n cessaire Reportez vous aux directives NFPA 54 pour plus de d tails G Les estimations d entr e montr es en Btu par heure sont pour des...

Страница 5: ...rger diameter line may be necessary Refer to the NFPA 54 guidelines for further details G Input ratings shown in BTU per hour are for elevations up to 2 000 ft For elevations above 2 000 ft refer to t...

Страница 6: ...ion entra nant des dommages mat riels des blessures ou des pertes de vie D Una pantalla de la chimenea debe ser en el lugar cuando el sistema est quemando Las provisiones para el aire de combusti n ad...

Страница 7: ...ration may result in fire or explosion resulting in property damage personal injury or loss of life D A fireplace screen must be in place when the system is burning Provisions for adequate combustion...

Страница 8: ...fireplace floor must not be blocked by the door frame the frame must have openings to allow for fresh air circulation Product Specifications Fig 8 1 Fireplace floor Fireplace opening burner system AS...

Страница 9: ...wire harness Battery pack Ignition module Fig 9 1 Insulatedcopper Black S I Main wire harness White Green Orange Red Black Main G a s inlet Step motor main flame Main gas out Pilot gas out Main flame...

Страница 10: ...vent opening listed in Table 3 below have a permanent stop installed remove the damper blade or have the damper cut to provide the minimum permanent opening required Note The minimum chimney height fr...

Страница 11: ...assembly propane PAC 12 PAC 12P 1 1 PAC 12 PAC 12P 1 1 2 or Control valve natural Control valve propane SV 47 SV 47P 1 1 SV 47 SV 47P 1 1 3 Control module remote receiver IMP 6 1 IMP 6 1 4 Main motor...

Страница 12: ...CK FOR LEAKS 6 At this stage the burner system batteries are to be installed Reference the INSTALLING REPLACING BATTERIES section for details 7 Place the switch box on its side at the rear left corner...

Страница 13: ...oor of the fireplace around the front and sides of the burner system see Fig 13 2 The lava granules may be placed around the switch box Leave the front of the switch box clear for control access 2 Rep...

Страница 14: ...itional embers to this log set Any additional embers will cause unsafe operation Important Adequate ventilation is absolutely necessary Provided significant noticeable sooting does not occur some flex...

Страница 15: ...ne 12V battery to operate included Locate the transmitter remove the lid found on rear and properly insert the new battery as marked Re secure the lid See Fig 15 1 SWITCH BOX BATTERIES Important Alway...

Страница 16: ...16 NOTES PAGE Please use this page to record any information that you may want to have at hand...

Страница 17: ...ON button OFF button Signal light REMOTE LIGHTING CAUTION DO NOT attempt to light the pilot by hand Note If the remote does not function and batteries with an adequate power level are installed refer...

Страница 18: ...nne pas et des batteries avec un niveau de puissance ad quate sont install s se r f rer la section synchronisation des REMOTE Note Les tapes 1 et 2 ne peuvent tre tenus si elle a d j fait au cours d u...

Страница 19: ...ral tries turn the system OFFandcontactaqualifiedprofessionalservicetechnician Note In manual mode the remote transmitter will not operate the burner system SHUTTING DOWN For remote shut down press th...

Страница 20: ...essais mettez le syst me hors tension et contactez un technicien qualifi Note En mode manuel la t l commande ne fonctionne pas du syst me de br leur TEINDRE Pour un arr t distance appuyez sur le touc...

Страница 21: ...em ON OFF BUTTON Turns the system OFF HI BUTTON When the system is on this button is used to increase the flame to the desired height LOW BUTTON When the system is on this button is used to decrease t...

Страница 22: ...S Lorsque le syst me est activ ce bouton est utilis pour augmenter la flamme la hauteur d sir e LOW TOUCHES Lorsque le syst me est activ ce bouton est utilis pour diminuer la flamme la hauteur d sir e...

Страница 23: ...ble In addition a periodic examination and cleaning of the solid fuel burning fireplace venting system should be conducted by a qualified professional service technician Any safety screen or guard rem...

Страница 24: ...ote Syncing the remote system will cause the burner to ignite Ensure the burner system is off and completely cool The remote receiver found on the rear of the burner assembly has a sync button see Fig...

Страница 25: ...to ensure sparking when activated Note You may need to turn or press igniter several times to ignite pilot See LIGHTING INSTRUCTIONS for your control valve C Igniter electrode wire loose C Check wirin...

Страница 26: ...A Contact your dealer for instructions on replacement B Pilot hood not aimed at thermocouple B Pilot hood bent replace pilot or angle pilot hood properly so pilot flame hits thermocouple C Pilot line...

Страница 27: ...ystem with Earthcore Please complete the warranty card included in this manual on the following page 1 The ISOFLAMES gas log burner has a one year warranty against any performance defects 2 The ISOFLA...

Страница 28: ..._________________________________________________________________ Gas Log Burner Size 24 30 Circle One Gas Control Valve Type remote control safety pilot Gas Type Natural Gas or Liquid Propane LP Circ...

Отзывы: