8
ISOFLAMES gas burner systems must be installed only in a wood burning fi replace with the
minimum fi rebox dimensions and venting requirements met (see table on this page). This appliance
is designed to burn with yellow fl ames; adequate ventilation is absolutely necessary.
SPECIFICATIONS
Table 1
- Product Specifi cations
Fireplace Floor Requirement
DO NOT install this burner system if the fi replace hearth is recessed.
The fi replace fl oor must be at
the same level as or larger than the fi replace front opening. An ash lip or recess may not exceed
3
/
4
". See
Fig. 8-1 below.
Note:
If glass doors are used: the fi replace fl oor must not be blocked by the door frame; the frame must
have openings to allow for fresh air circulation.
Product Specifi cations
Fig. 8-1
Fireplace
fl oor
Fireplace
opening
(burner
system)
ASH LIP OR
RECESS
ABOVE
3
/
4"
NOT
PERMITTED
Max.
3
/
4
"
ASH LIP OR
RECESS UP
TO
3
/
4"
PERMITTED,
Specifi cation
Value
Qty.
Burner system battery type
AA battery
4
Remote transmitter battery type
12V battery
1
Table 2
- Technical Data
Burner
Model
Dimensions
BTU Rating
Width
Depth
Height
Nat. Gas
L.P. Gas
Front
Rear
High
Setting
Low
Setting
High
Setting
Low
Setting
24/30 model (24" log set)
35"
25"
15"
16"
65k
21k
50k
22k
24/30 model (30" log set)
39"
28"
15"
16"
65k
21k
50k
22k
36/39 model (36" log set)
44"
32"
15"
16"
75k
22k
60k
23k
36/39 model (39" log set)
47"
32"
15"
16"
75k
22k
60k
23k
Note: Rear width is at corresponding depth.