the burning process]. This hard mass will block the air flow through the Burn Pot Liner and affect the
performance of the stove. Any fuel, even approved types, may tend to clinker. Check the Burn-Pot Liner
daily to ensure that the holes are not blocked with clinkers. If they become blocked, remove the liner
(when the unit is cold) and clean/scrape the clinkers out. Clean the holes with a small pointed object if
required. Refer to the section Routine Cleaning and Maintenance.
PELLET
FEED
RATES:
Due to different fuel densities and sizes, pellet feed rates may vary. This may
require an adjustment to the slider damper setting or to the auger feed trim setting on low.
Since stove supplier has no control over the quality of pellets that you use, we assume no liability for your
choice in wood pellets.
Store
pellets
at
least
36”
(1
m)
away
from
the
pellet
stove.
Caution: Keep the fire box clean, before you start the stove.
Introduction
I
MPORTANT
S
AFETY
D
ATA
:
Please
read
this
Owner’s
Manual
before
installing
or
operating
your
Pellet Stove.
Failure
to
follow
these
instructions
may
result
in
property
damage,
bodily
injury or
even
death.
Contact
your local building or fire official to obtain a permit and any information on installation restrictions and
inspection requirements for your area.
To prevent the possibility of a fire, ensure that the appliance is properly installed by adhering to the
installation instructions. The dealer will be happy to assist you in obtaining information with regards
to your local building codes and installation restrictions.
Be sure to maintain the structural integrity of the home when passing a vent through walls, ceilings, or
roofs.
The stove’s exhaust system works with negative combustion chamber pressure and a slightly positive
chimney pressure. It is very important to ensure that the exhaust system be sealed and airtight. The ash
pan and viewing door must be locked securely for proper and safe operation of the pellet stove.
Do not burn with insufficient combustion air. A periodic check is recommended to ensure proper
combustion air is admitted to the combustion chamber. Setting the proper combustion air is achieved by
adjusting the slider damper located on the left side of the stove.
When installing the stove in a mobile home, it must be electrically grounded to the steel chassis of the