Installation
1. Deciding Where to Locate your Pellet Appliance and
C
LEARANCES TO
C
OMBUSTIBLES
:
When installing this unit on a combustible floor (for example linoleum, hardwood flooring) a non-combustible
hearth pad
(15mm thickness)
must be under the unit. The pad must extend at least the width of the
appliance [22” (558 mm)] and at least the depth of the appliance plus 6” (153 mm) in front of the appliance
[29 3⁄4” (756 mm)].
The clearance between the walls or to the top is no more than the size in
the
figure.
Min. installation clearance (mm)
1
.
Electrical:
The unit must be grounded. The grounded electrical cord should be connected to a standard
220V, 50Hz
(4.5 Amps), (115 volts (4.5 Amps), 60 hertz) electrical outlet. Be careful that the
electrical cord is not trapped under the appliance and that it is clear of any hot surfaces or sharp edges
and also must be accessible. If this power cord should become damaged, a replacement power cord
must be purchased from the manufacturer or a qualified dealer.
2
.
Air input and venting pipe Installation
The stove air input pipe diameter is ¢50 mm, venting pipe diameter is ¢80 mm. The total length of pipes is
no longer than 3m and elbows are not available. Indoor venting pipe joint should be sealed by silicone
sealant to prevent exhaust leaking into the room. Venting pipe and termination should be waterproof and
avoid being blocked. Or, the stove can not work properly.
When the installation is limited by space or the owner’s special requirements and the pipes’ length should be
longer than 3m and need elbows, the diameters of the air input pipe and venting pipe must be increased