background image

PRODUCT FEATURES AND CONTROLS 

CARE AND OPERATI0N 

 

PAGE 13 

ASH DRAWER

 

The large ash drawer located on the left side of the ped-
estal is designed to make cleaning easier by containing 
the ashes in a removable drawer. 
 

 

 

CAUTION:  DO NOT OPERATE THE STOVE WITH 
THE ASH DRAWER OPEN OR AJAR, AS THIS WILL 
PRODUCE EXTREME TEMPERATURES WITHIN THE 
STOVE (OVERFIRING) AND COULD CAUSE DAMAGE 
(SUCH DAMAGE IS NOT COVERED BY THE MANU-
FACTURERS' WARRANTY).  REPLACE THE ASH 
DRAWER GASKET IF IT BECOMES FRAYED OR 
DAMAGED.

 

 

PRIMARY AIR CONTROL 

The primary combustion air delivery is controlled by the 
Primary Air Control Assembly (The control handle is lo-
cated below the fuel door). The heat output can be con-
trolled by sliding the handle to a higher or lower heat out-
put setting (See Care and Operation Section – 

Primary 

Air Control

, page 14). The fuel, the amount of heat and 

burn times desired, the type of installation are all vari-
ables that will affect the control setting. The same control 
settings in a variety of installations will produce different 
results. You will need to try different settings so you can 
learn how much heat to expect and how long the fire will 
burn

.

 The same control settings in a variety of installa-

tions will produce different results. You will need to try 
different settings so you can learn how much heat to ex-
pect and how long the fire will burn

 

 

FUEL DOOR 

 

CAUTION:  WHEN OPENING THE DOOR, DO NOT EX-
TEND IT BEYOND ITS NORMAL TRAVEL. OVEREX-
TENDING THE DOOR TO A FURTHER OPEN POSITION 
CAN PUT EXCESSIVE STRESS ON HINGE AREA OF 
DOOR AND HINGE PINS AND MAY RESULT IN BREAK-
AGE.

 

 

 

 
DOOR OPERATION 

The door handle assembly opens and securely latches 
the fuel door closed (see illustration above). To open the 
door, rotate the coil handle to the 9:00 position until door 
releases. To close and latch, hold the coil handle in the 
9:00 position, close the door, then rotate the handle to 
the 6:00 position. See illustration above. 

 

GLASS

 

The Glass is a super heat resistant ceramic that with-
stands continuous temperatures up to 1390°F. This tem-
perature is well beyond the temperatures in which you 
operate your stove. If the glass ever becomes damaged 
in any way, replace it, using only 5mm ceramic glass 
(catalog # G2000-7). 
 
This appliance is designed to provide a flow of air over 
the inside of the glass, which along with high heat helps 
keep it clean. When operating the stove on low for ex-
tended periods of time, the glass may get dirty. A short, 
hot fire (15 - 20 minutes) will help clean off much of the 
normal buildup (see troubleshooting). A commercial 
glass cleaner designed for stoves is recommended for 
cleaning. 
 

The glass should be cleaned thoroughly with glass 
cleaner and a soft cloth 

BEFORE

 the stove is burned.

 

 

Содержание EARTHSTOVE 1500HT

Страница 1: ...UAL RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE THIS APPLIANCE MUST BE INSTALLED BY A QUALIFIED INSTALLER READ ENTIRE MANUAL THOROUGHLY BEFORE INSTALLATION P P N 775001M Rev Q 12 03 MODEL 1500HT EP...

Страница 2: ...use gasoline gasoline type lantern fuel kerosene charcoal lighter fluid or similar liq uids to start or freshen up a fire in this heater Keep all such liquids well away from the heater while it is in...

Страница 3: ...eeds reflects their concern for aesthetics efficiency and our environment We extend our continued support to help you achieve the maximum benefit and en joyment available from your new wood stove It i...

Страница 4: ...ts in your area NOTE This appliance is NOT approved for installa tion into a Manufactured Mobile Home in Canada SELECTING A LOCATION The design of your home and where you place your stove will determi...

Страница 5: ...rrestor Clearances inches millimeters A 10 267 C 15 381 E 9 241 B 20 508 D 8 203 F 5 127 CORNER INSTALLATION PARALLEL INSTALLATION ALCOVE CLEARANCE Required pipe Type L Vent pipe to top of stove Ap pr...

Страница 6: ...air in a house that is well insulated OUTSIDE AIR In all manufactured mo bile homes and in many site built residences sub ject to local code a stove may be required to use outside air for combustion A...

Страница 7: ...To do this simply attach a piece of No 8 copper wire at least 18 457 mm in length from the stove to the chassis of the manufactured mobile home Marble is a natural product and therefore each piece wil...

Страница 8: ...be replaced Do not operate this appliance without the baffle brick properly installed TOP VIEW OF BAFFLE BRICK SIDE VIEW OF BAFFLE BRICK TYPES OF CHIMNEYS The chimney is a vital part of your stove ins...

Страница 9: ...epartment for chimney code requirements A masonry chimney must have a code approved liner This liner must not have broken or missing pieces Some non code masonry chimneys may be brought up to code by...

Страница 10: ...red flow of combustion air to the fire chamber and for safely removing unwanted combustion byproducts from the appliance If the venting system s design does not pro mote these ends the system may not...

Страница 11: ...ON PAGE 11 RESIDENTIAL STANDARD Using 6 152 mm Diameter Single Wall Con nector Pipe Not Approved For Manufactured Mobile Home MANUFACTURED MOBILE HOME STANDARD Using 6 152 mm Diameter Type L Vent Conn...

Страница 12: ...l of the Solid Pak chimney The in ner end of the Solid Pak chimney section shall be flush with the inside of the masonry chimney flue and sealed with a non water soluble refractory cement Use this cem...

Страница 13: ...ed to try different settings so you can learn how much heat to ex pect and how long the fire will burn FUEL DOOR CAUTION WHEN OPENING THE DOOR DO NOT EX TEND IT BEYOND ITS NORMAL TRAVEL OVEREX TENDING...

Страница 14: ...t least medium high or about 450 F for 45 60 minutes The paint will become soft and emit non toxic haze during these burns Keep the area well ventilated As the paint cures it will become slightly ligh...

Страница 15: ...l seasoned natural wood What does Well Seasoned mean When a tree is cut down the wood is green full of sap and moisture This moisture content can exceed 80 which must be reduced to less than 20 Wood p...

Страница 16: ...m all combustible materials pending final disposal If the ashes are disposed of by burial in soil or other wise locally dispersed they should be retained in the closed container until all cinders have...

Страница 17: ...ue are more susceptible to creosote deposits To inhibit the build up of creosote adjust the primary air control to a medium high or high setting for a 10 minute period each day Do not attempt to burn...

Страница 18: ...draw to sustain a high heat output rate DOES NOT MAINTAIN A FIRE 1 Soft wood does not burn as long or as well as seasoned hardwood resulting in a short burn time 2 Wood size too small Burns at too ra...

Страница 19: ...used From Improper Operation Operate this appliance only as outlined in this manual Never burn the ap pliance with the fuel door or ash drawer open or ajar Do not operate this stove with the Air Contr...

Страница 20: ...bs 16 kg Firebox Size 1 85 cubic feet 564 cubic mm Maximum Burn Rate BTU 58 730 EPA BTU Range 11 700 37 000 EPA Efficiency 63 Emissions Rate grams hour 6 6 gph Loading Front Approx weight with brick 3...

Страница 21: ...aft 907 Module Coil Handle brass Component Parts 1100 Ash Drawer Assembly 1135 Knob Ash Drawer 27M80H Gasket Ash Drawer 3 8 wide X 1 8 thick 13009 Trim Top Louver Fan System Parts if optional kit s in...

Страница 22: ...mensions FB 1 6 9 x 4 1 2 FB11 1 4 1 2 x 4 3 8 FB2 10 9 x 4 1 2 w notch 10545 5 9 x 4 1 2 w notch 01115 1 Grate FB 5 1 9 x 2 1 2 w hole Baffle brick are a special denser brick Do not substi tute Note...

Страница 23: ...Kit 14M22 BK 100 Blower Kit Includes Dial A Temp for Variable Speed Control 14M21 SSK Stove Stat Kit Thermally Controls Blower 70K99 TSPK B Touch up Spray Paint Kit Black 12 oz Spray Can Outside Air F...

Страница 24: ...SAFETY LISTING LABEL PAGE 24...

Страница 25: ...EPA LABEL PAGE 25...

Страница 26: ...26 OWNERSHIP RECORDS Dealer s Name Dealer s Address City State Zip Code Serial Number Date of Purchase Date Installed Notes SERVICE AND MAINTENANCE LOG Service Service Service Date Technician Descrip...

Страница 27: ...1110 West Taft Avenue Orange CA 92865...

Отзывы: