background image

4

CASTORS (MODEL SC165 OPTIONAL)

The castors are packed separately. Turn the boiler upside down and insert the 3 castors. These should be
pushed in hard until they stop. Once installed these remain in place permanently.

FILLING

SC75 

(see Fig.1)

Remove elbow filler cap and fill unit to Max. level indicator with clean - preferably hot   water.
Ensure that the ‘O’ ring is seated correctly on the elbow filler cap and place elbow filler cap lugs into filler hole
with the tongue pointing to the TWO O’CLOCK position. Turn the elbow filler cap clockwise to the SIX O’CLOCK
position so that the tongue locks into place between the two teeth.

SC77, SC125 & SC165 

(see Fig.2)

Remove filler cap and fill unit to Max. level line or indicator with clean - preferably hot water.
Replace filler cap.

If the unit requires refilling, unplug and allow to cool for at least 2 minutes before removing filler cap - Beware
of steam - and re-filling. When finished, allow to cool completely and empty unit. Always store unit empty.

SAFETY CUT- OUT

A safety cut-out is fitted to prevent overheating of the element if water boils below the Min. level.
If unit stops boiling during use this may be the cause. Wait for 2 minutes before removing filler cap then re-fill
with water. The cut-out will self reset and steam be produced again within 20 minutes.

The cut-out will not protect the element if a part filled unit is tilted during use in a way which enables
part of the element to be out of the water for longer than 15-20 seconds.

CHANGING TOOLS

Never remove the hose or change tools when the unit is plugged in. Wait 2 minutes after unplugging before
changing tools. Screw the nut, which is on the end of the steam hose, onto the outlet of the tool - 

hand tight

only.

Fig.1

Fig.2

SC75

SC77 SC125, SC165

Do not overfill the unit or hot water will be forced up the steam hose.

Screw hose onto threaded outlets of boiler and accessory, hand tight is sufficient.

Do not over tighten

but do check for hand tight fit from time to time during use.

Connect mains lead from unit to power socket and switch on. It can take approx 20 mins before steam is
produced - depending on fill water quantity and temperature.

Do not leave unattended and keep children & pets out of the room.

Just before full steam production a small amount of bubbling and water will occur at the accessory. 

Beware of

hot water discharge prior to steam emission.

Содержание SC125 - AUTRE

Страница 1: ... please read the instructions before commencing any work Please also make a special note of the safety rules EARLEX LTD WILL ACCEPT NO RESPONSIBILITY FOR THE USE OF THIS PRODUCT IF USED FOR ANY OTHER PURPOSES THAN THOSE DETAILED HEREIN RETAIN FOR FUTURE REFERENCE IF YOU HAVE ANY PROBLEMS WITH YOUR STEAM CLEANER OR IF YOU BELIEVE A PART IS MISSING DO NOT RETURN TO STORE PLEASE CONTACT EARLEX LTD ON...

Страница 2: ...ust be unplugged after use and before cleaning INTRODUCTION Thank you for purchasing an Earlex Steam Cleaning Kit The uses around the home car and garden are numerous and we hope you will find this product is in constant use to save time improve the look of your furnishings and to keep everything spotlessly clean When cleaning the Earlex Steam Cleaning Kit will brighten and refresh the colour and ...

Страница 3: ...connect in reverse order If you have any difficulty in disconnecting twist the handles apart Diagram 1 Assembling Handle Diagram 3 Fitting Long Handle Attachment Diagram 2 Seal Lubrication STEAM CLEANING KIT CONTENTS Please note Not all of the accessories shown in this instruction booklet are included in every steam cleaning kit To check the contents of your steam cleaning kit please refer to the ...

Страница 4: ...below the Min level If unit stops boiling during use this may be the cause Wait for 2 minutes before removing filler cap then re fill with water The cut out will self reset and steam be produced again within 20 minutes The cut out will not protect the element if a part filled unit is tilted during use in a way which enables part of the element to be out of the water for longer than 15 20 seconds C...

Страница 5: ...cleaning with long handle Cleaning tiles 5 FLOOR CLEANER IMPORTANT Some carpets have stain resistant treatments which have varying active Iives before breakdown Accordingly it is best to try a small area of carpet that is normally unseen then allow 24 hours to check whether the steam has any unusual effects on the carpet material e g white streaks If this happens DO NOT CONTINUE USE Check with you...

Страница 6: ...tiff wire or knitting needle Once steam is coming out under the surface of the water you will hear a rattle as the steam causes considerable vibration The combination of heat and vibration will loosen and dissolve the blockage Once the blockage starts to clear water should be run through while the sink unblocker is still operating to flush out the blockage UPHOLSTERY CLEANER OPTIONAL ACCESSORY NOT...

Страница 7: ... steam plate is held in place too long after the paper is soaked Weak plaster can normally be detected by tapping a few areas of wall A hollow sound indicates that you should proceed only with extreme care stopping immediately if you hear a cracking sound or plaster starts to break loose The steam stripper is safe for drywall plaster board surfaces but whatever the material it is always wise to ch...

Страница 8: ...hts This guarantee excludes the use for hire purposes In the event of a fault occuring please contact our helpline before returning the unit to our Service Department at the address below together with a copy of your purchase receipt All repairs will be dealt with speedily EC Declaration of Conformity We declare that the units SC75 SC76 SC77 SC125 SC165 conform to 2006 95 EC EN60335 1 EN60335 2 54...

Отзывы: