background image

 

The material contained in this document is the property of Electronics & Innovation Ltd., it  is 
subject to change without notice.  
 
May 2016 

12 

Revision G 

 

 
 
4.5     PACKAGING FOR RESHIPMENT 
 
In the event of the equipment being returned for servicing it should be packed in 
the original shipping carton and packing material. If this is not available, wrap the 
instrument  in  heavy  paper  or  plastic  and  place  in  a  rigid  outer  box  of  wood, 
fiberboard  or  very  strong  corrugated  cardboard.  Use  ample  soft  packing  to 
prevent  movement.  Provide  additional  support  for  projecting  parts  to  relieve 
these  of  unnecessary  shock.  Close  the  carton  securely  and  seal  with  durable 
tape. Mark the shipping container FRAGILE to ensure careful handling. 

 

 

 
Chapter 5 Safety: 
 

Do  not  attempt  to  operate  this  unit  with  the  cover  removed.  High  AC  and  DC 
voltages are present. The cover prevents against electrical shock due to AC line 
voltages,  high  DC  and  RF  fields.  Further  the  cover  provides  part  of  the  cooling 
system  design.  Components,  specifically  on  the  RF  driver  board  are  prone  to 
over-heat and eventual failure if the unit is operated without the cover in place. 
 
Ensure that the load is connected to the output prior to connecting the RF input 
to  the  unit.  This  will  prevent  high  voltages  being  present  and  exposed  at  the 
output connector.  
 
Only use the AC cord provided or equivalent.  
 
Ensure that the mains outlet is properly grounded. 
 
 
 

Содержание 3100LA

Страница 1: ...F VOLTAGES MAY BE PRESENT AT THE OUTPUT OF THIS UNIT All operating personnel should use extreme caution in handling these voltages and be thoroughly familiar with this manual Do not attempt to operate...

Страница 2: ...ly operational such that it performs according to the original specifications free of charge to the original purchaser Should warranty service be required the unit must be returned to E I freight cost...

Страница 3: ...FM SSB pulse and any complex modulation signals The amplifier has 50 dB gain it is unconditionally stable and will not oscillate even with combinations of mismatched source and load impedance It is p...

Страница 4: ...n 3 of full scale accuracy POWER REQUIREMENTS 100 240 VAC 47 63 Hz SIZE 5 3 5 3 x 16 5 x 18 4 134 134 5 mm x 420 mm x 467 mm WEIGHT 52 pounds 23 6 kg CONNECTORS N OPERATING TEMPERATURE 0 40 C RACK MOU...

Страница 5: ...ii Connect the output via a 50 ohm coaxial lead and N plug to the load iv Connect the input signal via a 50 ohm coaxial lead and N plug to the input connector 2 3 2 Front Panel Display The 3100LA fron...

Страница 6: ...ailable terminal programs such as Hyperterm The RS 232 link has the following parameters Baud rate 19200 Data bits 8 Parity none Stop bits 1 Flow control none An example configuration using HyperTermi...

Страница 7: ...The driver output signal is fed through a length of coaxial cable to the input of the splitter network The two output signals are fed to the two power amplifiers Each amplifier has a four way splitter...

Страница 8: ...an only be externally caused by the incorrect selection of the AC supply voltage or by an input signal in excess of the specified 1 volt rms equivalent to a power level of 13dBm This chapter therefore...

Страница 9: ...bserve the gain versus frequency ripple on an oscilloscope calibrated in decibels The gain variation must be not more than 1 5 dB over the frequency range e Connect a calorimetric power meter HP434 or...

Страница 10: ...ep generator to the video sweep mode with the start frequency at 150 kHz and the sweep width to 150 MHz c Disconnect the 3100LA from the set up and connect the sweep generator RF output directly to th...

Страница 11: ...armonics Figure 4 2 1 Equipment Required a Sweep Signal Generator b Calorimetric Power Meter HP435B c Spectrum Analyzer d Attenuator 30dB e Coupler 30 dB 2 Connect the Equipment as shown in Figure 4 2...

Страница 12: ...ck Close the carton securely and seal with durable tape Mark the shipping container FRAGILE to ensure careful handling Chapter 5 Safety Do not attempt to operate this unit with the cover removed High...

Отзывы: