13 

scanning  the frequency  band  of 10 KHz  to  5  MHz.  An  indicated  power 
output of 200W should be maintained during this operation. 

 
 
 
 
4.5     PACKAGING FOR RESHIPMENT 
 
In the event of the equipment being returned for servicing it should be packed in 
the original shipping carton and packing material. If this is not available, wrap the 
instrument  in  heavy  paper  or  plastic  and  place  in  a  rigid  outer  box  of  wood, 
fiberboard  or  very  strong  corrugated  cardboard.  Use  ample  soft  packing  to 
prevent  movement.  Provide  additional  support  for  projecting  parts  to  relieve 
these  of  unnecessary  shock.  Close  the  carton  securely  and  seal  with  durable 
tape. Mark the shipping container FRAGILE to ensure careful handling. 

 

 

 
Chapter 5 Safety: 
 

Do  not  attempt  to  operate  this  unit  with  the  cover  removed.  High  AC  and  DC 
voltages are present. The cover prevents against electrical shock due to AC line 
voltages,  high  DC  and  RF  fields.  Further  the  cover  provides  part  of  the  cooling 
system  design.  Components,  specifically  on  the  RF  driver  board  are  prone  to 
over-heat and eventual failure if the unit is operated without the cover in place. 
 
Ensure that the load is connected to the output prior to connecting the RF input 
to  the  unit.  This  will  prevent  high  voltages  being  present  and  exposed  at  the 
output connector.  
 
Only use the AC cord provided or equivalent.  
 
Ensure that the mains outlet is properly grounded. 
 
 
 

Содержание 1020L

Страница 1: ...out notice August 2012 Revision F 1 1020L Broadband Power Amplifier HIGH RF VOLTAGES MAY BE PRESENT AT THE OUTPUT OF THIS UNIT All operating personnel should use extreme caution in handling these volt...

Страница 2: ...ly operational such that it performs according to the original specifications free of charge to the original purchaser Should warranty service be required the unit must be returned to E I freight cost...

Страница 3: ...AM FM SSB pulse and any complex modulation signals The amplifier has 53 dB gain it is unconditionally stable and will not oscillate even with combinations of mismatched source and load impedance It i...

Страница 4: ...input signal 1 0 Volts RMS without damage And all load conditions at rated Power out POWER OUTPUT METER RMS power detection 3 of full scale accuracy 100 KHz 1 MHz 10 100 KHz see table below Above 1 M...

Страница 5: ...h With the handles removed it will fit into a standard rack 2 2 1 Mains Voltage The unit accommodates AC line voltages from 100 TO 240 VAC 47 63 Hz 2 3 OPERATION A line cord is supplied to form a conn...

Страница 6: ...r status see figure 2 1 Pf ___W Pr ___W Status ________ Figure 2 1 Front Panel Display Where Pf refers to forward power Pr refers to reverse power and Status indicates OK unless there is a fault condi...

Страница 7: ...nk has the following parameters Baud rate 19200 Data bits 8 Parity none Stop bits 1 Flow control none An example configuration using HyperTerminal on a PC is shown in figure 2 2 In the default state t...

Страница 8: ...e to the input of the power amplifier module The signal is split into two equal phase and amplitude signals These signals are fed to the inputs of transistors Q1 and Q2 The amplified signals appearing...

Страница 9: ...Maintenance 4 1 INTRODUCTION The E I 1020L RF amplifier requires no periodic maintenance The instrument is unconditionally stable and is fail safe under all load conditions Damage can only be externa...

Страница 10: ...he frequency range 10 KHz to 5 MHz to the input connector c Adjust the output level of the sweep generator so that a 50 ohm video detector connected at the output of the unit will not be damaged by ex...

Страница 11: ...pment as shown in Figure 4 1 then proceed as follows a Set the oscilloscope to DC Time cm to Ext X and gain to l0mv cm b Set the sweep generator to the video sweep mode with the start frequency at 10...

Страница 12: ...dB The gain variation should be within the 3 dB as shown on the oscilloscope 4 4 2 Measurement of Harmonics Figure 4 2 1 Equipment Required a Sweep Signal Generator b Calorimetric Power Meter HP434A...

Страница 13: ...upport for projecting parts to relieve these of unnecessary shock Close the carton securely and seal with durable tape Mark the shipping container FRAGILE to ensure careful handling Chapter 5 Safety D...

Отзывы: