background image

 

The material contained in this document is the property of Electronics & Innovation Ltd., it is 
subject to change without notice.  
 

August 2012                                                                                                                      Revision F 

 

 

Custom commands and display lists can be implemented upon customer 
request. 

 

 

 

Chapter 3 Technical Description  

 
3.1 GENERAL DESCRIPTION 

 
The 1020L is designed to amplify signals by 53 dB in the frequency band of  10 
KHz to 5 MHz. The signal from the front panel BNC connector is fed via a length 
of 50 ohm coaxial cable into the input of the driver amplifier module. The signal 
from  the  input  of  the  driver  is  coupled  to  the  input  of  the  MMIC  front  end.  The 
output  signal  of  the  MMIC  is  coupled  to  the  gate  of  transistor  Q1.  The  further 
amplified signal appearing at the drain of Q1 is coupled to the input of Q2. This is 
transformed to 50   and fed to the driver output BNC port.  
 
The driver output signal is fed through a length of coaxial cable to the input of the 
power  amplifier  module.  The  signal  is  split  into  two  equal  phase  and  amplitude 
signals.  These  signals  are  fed  to  the  inputs  of  transistors  Q1  and  Q2.  The 
amplified signals appearing at the drains of Q1 and Q2 are then fed to the output 
BNC port via the impedance matching network.  
 
The  power  amplifier  output  signal  is  then  fed  into  a  length  of  50  ohm  coaxial 
cable  to  the  RF  bi-directional  coupler.  The  output  of  the  coupler  is  then  fed 
directly to the BNC connector on the front panel, this is the unit output. 
 
The forward and reverse coupled ports of the bi-directional coupler are fed to the 
RF detector which is situated on the main control board. The RF detector feeds a 
voltage,  which  is  representative  of  the  true  RMS  power  to  the  control  board 
proper. The control board in turn drives the front panel display. 
 
The  main  power  supply  unit  provides  a  42/24  VDC  12  ampere  source.  It  is  a 
switch mode power supply unit. The 42 V output feeds the PA. The 24 V provides 
power for the drive amplifier.  The power supply also has a 5 VDC output  which 
feeds the control board. 
 

Содержание 1020L

Страница 1: ...out notice August 2012 Revision F 1 1020L Broadband Power Amplifier HIGH RF VOLTAGES MAY BE PRESENT AT THE OUTPUT OF THIS UNIT All operating personnel should use extreme caution in handling these volt...

Страница 2: ...ly operational such that it performs according to the original specifications free of charge to the original purchaser Should warranty service be required the unit must be returned to E I freight cost...

Страница 3: ...AM FM SSB pulse and any complex modulation signals The amplifier has 53 dB gain it is unconditionally stable and will not oscillate even with combinations of mismatched source and load impedance It i...

Страница 4: ...input signal 1 0 Volts RMS without damage And all load conditions at rated Power out POWER OUTPUT METER RMS power detection 3 of full scale accuracy 100 KHz 1 MHz 10 100 KHz see table below Above 1 M...

Страница 5: ...h With the handles removed it will fit into a standard rack 2 2 1 Mains Voltage The unit accommodates AC line voltages from 100 TO 240 VAC 47 63 Hz 2 3 OPERATION A line cord is supplied to form a conn...

Страница 6: ...r status see figure 2 1 Pf ___W Pr ___W Status ________ Figure 2 1 Front Panel Display Where Pf refers to forward power Pr refers to reverse power and Status indicates OK unless there is a fault condi...

Страница 7: ...nk has the following parameters Baud rate 19200 Data bits 8 Parity none Stop bits 1 Flow control none An example configuration using HyperTerminal on a PC is shown in figure 2 2 In the default state t...

Страница 8: ...e to the input of the power amplifier module The signal is split into two equal phase and amplitude signals These signals are fed to the inputs of transistors Q1 and Q2 The amplified signals appearing...

Страница 9: ...Maintenance 4 1 INTRODUCTION The E I 1020L RF amplifier requires no periodic maintenance The instrument is unconditionally stable and is fail safe under all load conditions Damage can only be externa...

Страница 10: ...he frequency range 10 KHz to 5 MHz to the input connector c Adjust the output level of the sweep generator so that a 50 ohm video detector connected at the output of the unit will not be damaged by ex...

Страница 11: ...pment as shown in Figure 4 1 then proceed as follows a Set the oscilloscope to DC Time cm to Ext X and gain to l0mv cm b Set the sweep generator to the video sweep mode with the start frequency at 10...

Страница 12: ...dB The gain variation should be within the 3 dB as shown on the oscilloscope 4 4 2 Measurement of Harmonics Figure 4 2 1 Equipment Required a Sweep Signal Generator b Calorimetric Power Meter HP434A...

Страница 13: ...upport for projecting parts to relieve these of unnecessary shock Close the carton securely and seal with durable tape Mark the shipping container FRAGILE to ensure careful handling Chapter 5 Safety D...

Отзывы: