EAGLE-II Swing Gate Operator
____________________
Connecting The Power
Be sure that the circuit breaker for the line input power is turned off before connecting the input power to the unit.
CAUTION!
!
Connect 120 VAC, 15A, 60HZ, line input power
to the wires provided in the power switch junction
box located near the bottom of the operator.
The wires are color coded as follows:
SUGGESTED WIRE
Black - 120 VAC / Line Input Power
White - Neutral Input
Green - Ground Input (from an approved grounding method)
14 AWG
250 ft.
12 AWG
400 ft.
10 AWG
650 ft.
8 AWG
1000 ft.
4 AWG
2000 ft.
____________________
Reverse / Exit Loop Installation
The Purpose for a reversing loop is to prevent the gate from closing on a vehicle while it is exiting or stopped
in the middle of the gate area. The purpose of the exit loop is to automatically open the gate when a vehicle
approaches to exit.
Exit Loop Operation
Wires must be
wrapped inside
the groove three
times. Once you
have completed
the process, fill
up the grooves
with a proper
sealant.
Eagle Access Control Systems, Inc. / (800) 708-8848 / www.eagleoperators.com
(9)
All units must be properly grounded
Warning:
Eagle Access Control Systems, Inc.
is not responsible for researching and complying
with local building codes. Be sure to check
these codes before installation.
!
OUT
IN
LOOP CUT
TWISTED WIRES
WIRE LAYERS
IN LOOP CUT
PROPER SEALER SHOULD
BE USED IN LOOP CUTS
PHANTOM LOOP
EXIT LOOP
REVERSE LOOP
REVERSE LOOP
Содержание Power II