background image

____________________

Receiver Connections

4-Wire Connections

3-Wire Connections

The Receiver Terminal is mounted on the control box for easy

  installation and is pre-wired for a 3-wire or 4-wire receiver.

   (24V)

COMMON

    GRD

   (24V)

COMMON

    GRD

Receiver Connections
on the Eagle Diamond
Board

____________________

EAGLE-II Swing Gate Operator

(17)

Eagle Access Control Systems, Inc. / (800) 708-8848 / www.eagleoperators.com

Gate Travel Distance / Setting The Limit Switches

    The limit switches must be set so that the gate stops at the proper

position.

Limit Switches

Loosen Screws

Make Adjustments

1

2

Tighten Screws

3

Содержание Power II

Страница 1: ...I NSTALLATION M ANUAL ...

Страница 2: ...ctions Gate Travel Distance Setting the Limit Switches Emergency Release Resetting the Motor Adjusting the Operator s Clutch Troubleshooting Page 3 Page 5 Page 6 Page 7 Page 8 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 15 Page 16 Page 17 Page 17 Page 18 Page 18 Page 18 Page 19 2 Eagle Access Control Systems Inc 800 708 8848 www eagleoperators com All rights reserved No part of this manual ...

Страница 3: ...zed use 6 All warning signs and placards must be installed where visible in the area of the gate 7 For a gate operator utilizing a non contact sensor such as a photo beam See instructions on the placement of non contact sensor for each type of application Care shall be given to reduce the risk of nuisance tripping such as when a vehicle trips the sensor while the gate is still moving One or more n...

Страница 4: ...ar entrance or exit to a drive parking lot or the like UL Listings __________________________________________ Gate A moving barrier such as a swinging sliding raising lowering rolling or like barrier that is a stand alone passage barrier or is that portion of a wall or fence system that controls entrance and or egress by persons or vehicles and completes the perimeter of a defined area ___________...

Страница 5: ...s CAUTION ____________________ Eagle swing gate operators are for vehicular use only They are not for pedestrian use ____________________ Closing Be sure to mount ALL operating devices clearly out of reach through gate Regarding Ornamental Grill Styled Gates Injuries may be avoided if a mesh or screen is installed on the gate Injuries resulting from hands and feet becoming stuck in gate or childre...

Страница 6: ... for COMPACT INSTALLATIONS only Gate Open Position A B C D E 1 2 3 4 24 36 11 11 11 26 20 17 2 30 27 38 28 29 5 31 32 5 25 5 37 28 5 39 NOTE If this dimension is less than 35 inches compact installation is ne cessary Refer below REFER TO NOTE B B E A D C HINGE CENTER OUT IN LONG ARM SHORT ARM CONCRETE PAD 20 Failure to follow these instructions could result in serious injury When gate is in fully ...

Страница 7: ..._______ Eagle Access Control Systems Inc 800 708 8848 www eagleoperators com 7 Welding The Gate Arm Incorrect Installation Correct Installation W A L L ____________________ Weld The Bracket On The Gate Once The Gate Arm Measurements Are Calculated All Secondary Entrapment Sensors Are Connected To Edge Sensor Inputs EXAMPLE OF PHOTOCELL SENSORS Transmitter Receiver ...

Страница 8: ...Access Control Systems Inc 800 708 8848 www eagleoperators com 8 Recommended Dimensions ____________________ 5 20 20 R E D H E A D F A S T E N E R 1 2 x 3 1 2 Concrete Pad Diagram N T S The following concrete recommendations are installation suggestions only Please consult local codes for actual requirements in your area 20 To select the opening direction of the gate use the Feature Selector as sh...

Страница 9: ...on The Purpose for a reversing loop is to prevent the gate from closing on a vehicle while it is exiting or stopped in the middle of the gate area The purpose of the exit loop is to automatically open the gate when a vehicle approaches to exit Exit Loop Operation Wires must be wrapped inside the groove three times Once you have completed the process fill up the grooves with a proper sealant Eagle ...

Страница 10: ...parate pots for adjusting sensitivity One is for opening the gate and the other is for closing the gate There is an LED OVERLOAD warning that will light up when the gate is heavier than normal for the operator During this warning the operator will not function properly IMPORTANT Too Sensitive if the gates stops or reverses by itself Not Sensitive enough if the gate strikes an object and does not s...

Страница 11: ...eset the micropressor IF YOU MAKE A CHANGE WITH THE SWITCHES YOU MUST USE THE RESET BUTTON TO APPLY CHANGES Note If the power light is on and the operator does not function press the reset button once If this does not solve the problem proceed with turning off the power switch and then switching it back on again Switch 1 Slave Master Sets the operator to work as Master or Slave Switch 2 Open left ...

Страница 12: ...g The Accessories Reverse Loop Photo Eye Phantom Loop Exit Loop Key Lock Box Fire Lock Box MAG Lock Phone Entry System Edge Sensor Eagle Access Control Systems Inc 800 708 8848 www eagleoperators com 12 EAGLE II Swing Gate Operator ...

Страница 13: ...Operators are not communicating properly verify if they are on the same phase by switching the phase jumper on either the master or the Slave Unit Master and Slave Operation ____________________ Set dip switch 1 ON for the Master Set dip switch 1 OFF for the Slave Use the feature selector on the master operator to choose available features by designating the various switches 2 through 4 EAGLE II S...

Страница 14: ...to the Slave or to the off position Switch 2 Set to the open left or to the open right position Switch 3 Set motor to ON or OFF position Switch 4 Set to OFF position 14 Eagle Access Control Systems Inc 800 708 8848 www eagleoperators com EAGLE II Swing Gate Operator ...

Страница 15: ... Solenoids The Control Board provides 24 VAC Power which can be used for loop detectors and receivers Safety Alarm If the gate hits an obstruction twice while closing or opening the system will shut down for 5 minutes On the Board you have two options of reset mode Entire Output Section EAGLE II Swing Gate Operator 15 Eagle Access Control Systems Inc 800 708 8848 www eagleoperators com ...

Страница 16: ...Edge Sensor Input Phantom Loop Momentary or Continuous Signal This input is active only when the gate is at rest in the fully open position The input has no effect on the gate when fully closed or while closing or opening Continuous activation will prevent the gate from moving in the close direction When the input is removed normal operation is resumed This input is intended for a vehicle loop det...

Страница 17: ...ceiver 24V COMMON GRD 24V COMMON GRD Receiver Connections on the Eagle Diamond Board ____________________ EAGLE II Swing Gate Operator 17 Eagle Access Control Systems Inc 800 708 8848 www eagleoperators com Gate Travel Distance Setting The Limit Switches The limit switches must be set so that the gate stops at the proper position Limit Switches Loosen Screws Make Adjustments 1 2 Tighten Screws 3 ...

Страница 18: ... Operator s Clutch EAGLE II Swing Gate Operator To release operator simply unscrew bolt remove the top cap and lift the arm Use an appropriate wrench to adjust the clutch Depending on the weight of the gate clutch slippage may occur Typical Clutch slippage is about 1 4 turn If it does not slip readjust the Clutch accordingly ...

Страница 19: ...a possible short circuit C Only key keypad and receiver will resume normal operation D Reset Loop Detector verify correct wiring set to a differ ent frequency and or change the sensitivity of the Loop Detector E Be sure that the Close Timer switch 4 is set to the on position Gate will not OPEN A Motor overload B Radio Receiver is not on when the remote control is activated C The green LED is off D...