5. EV3000-D Wiring:
1) AC 24V Power Connection Terminals (Use AWG16 or 18 Wire)
-
AC24V POWER
-
AC24V COM
2) Earth Terminal
-CONNECT EARTH LINE TO
࠰
Terminal
2) Thermal camera Video Connection Terminals
-
THERMAL VIDEO (BNC)
-
THERMAL SVIDEO (4-PIN DIN CONNECTOR)
3) Day/night camera Video Connection Terminal
-
DAY/NIGHT VIDEO (BNC)
4) RS422 Data Communication line Connection Terminals
-
TX+ (FROM EV3000-D TO OUTSIDE CONTROLLER or PC)
-
TX- (FROM EV3000-D TO OUTSIDE CONTROLLER or PC)
-
RX+ (FROM OUTSIDE CONTROLLER or PC TO EV3000-D)
-
RX- (FROM OUTSIDE CONTROLLER or PC TO EV3000-D
-
SHIELD: NO CONNECTION or CONNECT SHIELD WIRE OF
OUTSIDE RS-422 DATA COMMUNICATION LINES
5) Pump Connection Terminals: Connect to DC24V+, DC24V- Terminals