Timing Direction:
Determines whether the time values for Preset 1 and 2 will increment from
zero and change the state of the output at the set value (uP) or decrement from the set value and
change the state of the output at zero (dn).
t d i r
u P
P
P
1st Operation:
Determines whether the time cycle will start with an "On" operation (Output 1
active) or an "Off" operation (Output 1 inactive). Please note that since preset 1 and preset 2
apply to Operation 1 and Operation 2 respectively, changing this parameter will also affect the
function of each preset (ie: Preset 1 will change from the On time to the Off time, if "Off" is
chosen for this parameter).
P
C O N F I G U R A T I O N
1 S t
O n
t r n 1
Time Range 1 :
Sets the unit of measure for the time values that will be used for Preset 1.
Choices are:
• Seconds
• Minutes
• Hours
• Minutes:Seconds
• Hours:Minutes
Decimal Position for Time Range 1:
Determines the resolution of the selected time range.
Settable from 0000 to 0.000
Note: The following parameter will not appear if "Minutes:Seconds" or
"Hours:Minutes" is chosen for Time Range 1.
Time Range 2 :
Sets the unit of measure for the time values that will be used for Preset 2.
Choices are:
• Seconds
• Minutes
• Hours
• Minutes:Seconds
• Hours:Minutes
Note: The following parameter will not appear if "Percentage" is chosen as the
Operating Function.
Decimal Position for Time Range 2:
Determines the resolution of the selected time range.
Settable from 0000 to 0.000
Note: The following parameter will not appear if "Minutes:Seconds" or
"Hours:Minutes" is chosen for Time Range 2.