Timing Direction:

  Determines whether the time values for Preset 1 and 2 will increment from

zero and change the state of the output at the set value (uP) or decrement from the set value and
change the state of the output at zero (dn).

t d i r

u P

P

P

1st Operation:

  Determines whether the time cycle will start with an "On" operation (Output 1

active) or an "Off" operation (Output 1 inactive).  Please note that since preset 1 and preset 2
apply to Operation 1 and Operation 2 respectively, changing this parameter will also affect the
function of each preset (ie: Preset 1 will change from the On time to the Off time, if "Off" is
chosen for this parameter).

P

C O N F I G U R A T I O N

1 S t

O n

t r n 1

Time Range 1 : 

 Sets the unit of measure for the time values that will be used for Preset 1.

Choices are:

• Seconds
• Minutes
• Hours
• Minutes:Seconds
• Hours:Minutes

Decimal Position for Time Range 1:

  Determines the resolution of the selected time range.

Settable from 0000 to 0.000

Note:  The following parameter will not  appear if "Minutes:Seconds" or
"Hours:Minutes" is chosen for Time Range 1.

Time Range 2 : 

 Sets the unit of measure for the time values that will be used for Preset 2.

Choices are:

• Seconds
• Minutes
• Hours
• Minutes:Seconds
• Hours:Minutes

Note:  The following parameter will not  appear if "Percentage" is chosen as the
Operating Function.

Decimal Position for Time Range 2:

  Determines the resolution of the selected time range.

Settable from 0000 to 0.000

Note:  The following parameter will not  appear if "Minutes:Seconds" or
"Hours:Minutes" is chosen for Time Range 2.

Содержание B506

Страница 1: ...lication Additionally included are key product specifications warranty procedures and ordering information should you require additional units or accessories Should you require any additional assistan...

Страница 2: ...until there is a snug fit against the panel Do not overtighten 48mm 8mm 66mm 81mm B506 7051 2 1 11 2 3 4 5 6 7 8 9 10 AC Power AC Power Warning Do Not connect a coil in parallel with the start signal...

Страница 3: ...currently displayed parameter Edit Key In Control Mode Displays the settable value used to trigger the timed output s and the batch count if configured In Program Mode Displays the current selection...

Страница 4: ...s are Stop StoP The timing cycle will halt after the number of cycles set for the Batch Count is completed To activate another cycle it is necessary to reset the unit and provide a start signal Contin...

Страница 5: ...I G U R A T I O N 1 S t O n t r n 1 Time Range 1 Sets the unit of measure for the time values that will be used for Preset 1 Choices are Seconds Minutes Hours Minutes Seconds Hours Minutes Decimal Pos...

Страница 6: ...the E and P keys If inactive OFF the timing operation can only be reset through the remote input P P P r S t O n F r S t O n Security Level 4 different levels of security are available 0 Full Access...

Страница 7: ...g edge of start signal or after completion of P1 based on programming On completion of P1 or Reset On reaching the Batch Count Preset Value or Reset Output 2 When the Batch Count Value equals the Batc...

Страница 8: ...rized repairs to its components even though defective The life of the products of the Company depends to a large extent upon the type of usage thereof and THE COMPANY MAKES NO WARRANTY AS TO FITNESS O...

Отзывы: