Time Range Indicator
Illuminates to show the time base: H for
hours, M for minutes, S for seconds.
Multiple indicators will be illuminated
when the time base is Hours:Minutes or
Minutes:Seconds. During timing
operation the illuminated LED will flash.
Illuminates to display when an input or output is
active: "IN' for the start input, "O1" and "O2" for
the timed outputs.
I/O Status Indicators
Preset 2 Indicator
Primary Display
In Control Mode:
Displays the
current time value associated with
the displayed preset or the batch
value (if configured).
In Program Mode:
Displays the
Parameter Description.
4 3 2 1
EAGLE SIGNAL
E
P
1234
1234
H
M
S
IN
O1
O2
P2
B
Each of the number keys is used to
increment the value of the
corresponding digit of the preset or a
parameter value.
Numeric Keys
In Control Mode:
Depressing the key will scroll the display
among the preset and batch displays. Holding the key
down for 3 seconds will shift the unit into Program Mode.
In Program Mode:
Depressing the key will scroll the
display from one parameter to the next. Holding the key
down for 3 seconds will shift the unit back to Control
Mode.
Program Key
In Control Mode:
With "P" key, resets the displayed value.
In Program Mode:
Scrolls between the applicable choices for the
currently displayed parameter.
Edit Key
In Control Mode:
Displays the settable
value used to trigger the timed
output(s) and the batch count (if
configured).
In Program Mode:
Displays the current
selection for the chosen parameter.
Set Value
Illuminates to indicate that the Batch Count
Value and Batch Preset are being displayed.
Batch Indicator
Preset 1 Display
Preset 2 Display
Batch Display
P
P
4 3 2 1
EAGLE SIGNAL
E
P
4321
5555
H
M
S
IN
O1
O2
P2
B
4 3 2 1
EAGLE SIGNAL
E
P
1234
1234
H
M
S
IN
O1
O2
P2
B
4 3 2 1
EAGLE SIGNAL
E
P
1234
P 40
H
M
S
IN
O1
O2
P2
B
The lower display will indicate the
value for Preset 1 in one of two
manners:
In Standard Mode:
Will display the
time interval for the 1st operation of
the cycle.
In Percentage Mode:
Will display the %
of the total time base (P2) applied to
the 1st operation of the cycle.
The lower display will indicate the value
for Preset 2 in one of two manners:
In Standard Mode:
Will display the time
interval for the 2nd operation of the
cycle.
In Percentage Mode:
Will display the
total time base for the cycle.
The upper display will indicate the
current Batch Count Value, while the
lower display will indicate the Batch
Preset. A setting of "0" will disable
output 2.
Note: The Batch Display will not
appear if "int" is chosen as the
function for Output 2 in Program
Mode.
Illuminates to indicate that the Preset 2 is being
shown on the lower display.
O P E R A T I O N
FRONT PANEL OPERATION
CONTROL MODE