background image

  SYSTEM AIR PURGE PROCEDURE

2. Turn release valve counter-clockwise on full turn 

to the open position.

1. Remove cover plate.

3. Rapidly pump the handle 6-8 times. Leave handle 

slightly to the side to purge trapped air from 

system. (Use caution not to tear or puncture the 

oil plug.)

5. Replace Cover Plate.

6. Turn release valve clockwise to the closed 

position.

7. Jack is now ready for use. Check for proper pump 

action. (Repeat steps if neccessary).

IMPORTANT: BEFORE FIRST USE

Perform the following Air Purge Procedure to remove any air that may have been introduced into the hydraulic system as a 

result of product shipment and handling. This step is to be completed without any weight on the jack.

Cover plate

Cover plate

www.eagleprojacks.net

Содержание E1525P

Страница 1: ... operating instructions before using this product Lifting Capacity Ton Max Height mm Min Height mm Gross Weight kg Net Weight kg Package Size mm 2 5 510 7 32 5 30 5 777X383X200 SPECIFICATIONS Item No TL 1525P E1525P OPERATOR S MANUAL 2 5 TON GARAGE JACK ...

Страница 2: ...before operating this device Inspect the jack before each use Do not use jack if damaged altered modified in poor condition leaking hydraulic fluid or unstable due to loose or missing components Make corrections before using Lift only on areas of the vehicle as specified by the vehicle manufacturer Wear eye protection that meets OSHA standards users and bystanders Do not use jack beyond its rated ...

Страница 3: ...ndle to lifting the jack OPERATING INSTRUCTIONS Important Sometimes during shipment and handling air gets into the hydraulic system causing poor lifting performance Before initial operation purge any air from the system by fully opening pump release valve turn handle counter clockwise Then while holding the saddle down pump handle rapidly several times www eagleprojacks net ...

Страница 4: ...e oil plug 5 Replace Cover Plate 6 Turn release valve clockwise to the closed position 7 Jack is now ready for use Check for proper pump action Repeat steps if neccessary IMPORTANT BEFORE FIRST USE Perform the following Air Purge Procedure to remove any air that may have been introduced into the hydraulic system as a result of product shipment and handling This step is to be completed without any ...

Страница 5: ...onal injury hazards Obey all instructions to avoid possible injury or death 1 Always store the jack in a well protected area where they will not be exposed to inclement weather corrosive vapors abrasive dust or any other harmful elements The jack must be cleaned of water snow sand grit oil grease or other foreign matter before using 2 The jack must be lubricated periodically in order to prevent pr...

Страница 6: ... bystanders around the jack or under the load when lowering the jack 5 After removing jack from under the load keep jack in the lowered position to reduce exposure to rust and contamination NOTE Always store jack in the fully lowered position and the handle in the upright position To Add Jack Oil 1 Position the jack on level ground and 4 Fill the oil case until oil level is just beneath the lower ...

Страница 7: ...Remove the oil plug 6 Position the jack on level ground and keep saddle in the lowered position Fill the oil case until oil level is just beneath the lower rim Keep dirt and other foreign materials clear when pouring 5 Turn the jack on its side to drain old oil from the oil fill hole 7 Replace oil plug 8 Replace coverplate and perform the Air Purge Procedure www eagleprojacks net ...

Страница 8: ...MAIN BODY ASSEMBLY www eagleprojacks net ...

Страница 9: ...e ReWeight Capacity Exceeded Air is in the hydraulics Purge air from system Low oil level Add oil as required Jack is binding or foreign obstruction Power unit malfunctioning Replace the power unit Drain excessive oil Lubricate moving parts Part List Item No Description Q TY Item No Description Q TY 1 Front Wheel 2 24 Idler Wheel 1 2 Retainer Ring 20 4 25 Small Handle Socket 1 3 Washer 16 2 26 Was...

Отзывы: