Connecting The Power
Be sure that the circuit breaker for the line input power is turned off before connecting the input power to the unit.
CAUTION!
!
Connect 120 VAC, 15A, 60HZ, line input power
to the wires provided in the power switch junction
box located near the bottom of the operator.
The wires are color coded as follows:
Black - 120 VAC / Line Input Power
White - Neutral Input
Green - Ground Input (from an approved grounding method), the unit must be grounded
14 AWG
250 ft.
12 AWG
400 ft.
10 AWG
650 ft.
8 AWG
1000 ft.
4 AWG
2000 ft.
____________________
Reverse / Exit Loop Installation
The purpose of a reversing loop is to prevent the gate from closing on a vehicle while it is exiting or stopped
in the middle of the gate area. The purpose of the exit loop is to automatically open the gate when a vehicle
approaches to exit.
Exit Loop Operation
Wires must be
wrapped inside
the groove three
times. Once you
have completed
the process, fill
up the grooves
with a proper
seal.
Distributed by AFW Access Systems • www.AnchorMiami.com/afwas
(9)
All units must be properly grounded
!
Warning:
Eagle Access Control Systems, Inc
is not responsible for researching and complying
with local building codes. Be sure to check
into these codes before your installation.
LOOP CUT
TWISTED WIRES
WIRE LAYERS
IN LOOP CUT
PROPER SEALER
SHOULD BE USED
IN LOOP CUTS
REVERSE LOOP
REVERSE LOOP
EXIT LOOP