© EA Elektro-Automatik, DE-41747 Viersen, Helmholtzstr. 31-33, Tel. 02162-3785-0, Fax. 02162-16230
15
提示
/ Hints
提示
-
电源插头必须插进无障碍电源插座上。
-
输出端的极性可通过
PCB "UMPOLER"
从内部反接。
该操作仅可由受训人员来执行。
- 300V
以上型号的
0V-HV
输出端与安全接地器
PE
从内部
相连。若输出端已反接,则
+
输出端要接到安全接地器
PE
。
-
用螺丝刀可从前板调节过压保护值
(OVP)
。按下
"Preset"
按钮该数值可显示于电压表上。若
OVP
被激活,可激
活
"Reset"
按钮使本产品恢复至正常模式。
-
随附插头必须一直插到模拟接口插座上。见
14
页。
Hints and tips
- The mains plug must be connected into a free acces-
sible mains socket.
- The polarity of the output can be internally reversed by
means of the PCB "UMPOLER".
This may only be carried out by trained personnel.
- On units above 300V the 0V-HV output is internally
connected with the safety ground connector PE.
In case the output has been reversed, than the +
output is connected to the safety ground
connector PE.
- The overvoltage protection (OVP) can be adjusted on
the front panel by means of a screw driver. The value
can be indicated on the voltmeter after pressing the
"Preset" button. In case the OVP is activated, the unit
can be reset to normal operation by activating the "Re
-
set" button.
- The included plug must always be plugged in to the
analogue interface socket. See page 14.