INSTRUCTION MANUAL 

IS-mC1    Min

ia

lert 

Intrinsically Safe Round Combined Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1)  Introduction 

 

The IS-mC1 minialert is an ATEX, IECEx and UKEX certified 

intrinsically  safe  combined  sounder/beacon  unit  which 

produces both a loud audio warning and a visual warning and 

can  be  installed  in  a  hazardous  area.  The  sounder  section 

has forty-nine first stage alarm sounds that can be selected 

by internal switches and each one can be externally changed 

to a second or third stage alarm sound. The beacon section 

can be set internally for a flash rate of either 1Hz or 2Hz. The 

combined  unit  sounder  and  beacon  can  be  operated 

simultaneously  from  one  barrier  or  from  separate  barriers  if 

independent  operation  is  required.  The  IS-mC1  Combined 

Unit can be used in all gas groups IIA IIB and IIC.  

 

2)  Description 

 

Fig  1  shows  a  simplified  block  diagram  of  an  IS-mC1 

minialert  sounder  section.  The  device  operates  immediately 

power is applied to the s and – terminals which are 

duplicated  to  allow  a  second  sounder  to  be  connected  in 

parallel,  or  for  an  end  of  line  monitoring  resistor  to  be 

installed.  The  output  tone  is  defined  by  the  positions  of  the 

six  internal  switches  and  this  tone  can  be  changed  to  a 

second or third stage alarm tone by connecting terminals S2 

or S3 to 0V. The tone generator is crystal controlled to ensure 

that when two sounders connected to the same power supply 

are  started  at  the  same  time  the  output  tones  remain 

synchronised. 

 

3) 

Supply Voltage

 

 

The IS-mC1 minialert unit has been designed to operate in a 

hazardous area from a 24V dc supply via 28V 93mA resistive 

ATEX  and  IECEx  certified  Zener  Barriers  or  Galvanic 

Isolators.  The  unit  may  be  tested  or  used  in  safe  areas 

without  a  Zener  Barrier  or  Galvanic  Isolator,  but  at  supply 

voltages above 16V the internal current limit will function and 

therefore  it  is  recommended  that  they  are  not  operated 

continuously with a direct supply greater than 16V. 

 

IS-mC1 Sounder Section

Tone Generator

Tone Selection Switches

Volume Control

_

_

S2

S3

+

+

 

Fig 1 Simplified block diagram 

 

4) 

Intrinsic Safety Certification

 

 

4.1 ATEX certificate 

The  IS-mC1  combined  minialert  unit  complies  with  the 

following standards:-  

 

EN IEC 60079-0:2018 

EN60079-11:2012 

IEC60079-26:2014 

 

 

 

The  EC-Type  Examination  Certificate  SIRA  05ATEX2084X 

has  been  issued  by  the  Notified  Body  Sira.  This  confirms 

compliance  with  the  European  ATEX  Directive  2014/34/EU 

for  Group  II,  Category  1G  equipment.   The sounder carries 

the Community Mark and subject to local codes of practice, 

may be  installed  in  any of  the  EEA member countries. This 

instruction  sheet  describes  installations  which  conform  to 

EN60079:Part14:2008  Electrical  Installation  in  Hazardous 

Areas.   When  designing systems for installation  outside the 

UK, the local Code of Practice should be consulted. 

 

1) 

The certification marking is as follows:  

e

2S

european safety systems ltd. 

London W3 7QH UK

WARNING: 

TO AVOID A POSSIBLE ELECTROSTATIC

 

CHARGE ONLY CLEAN WITH A DAMP CLOTH 

IS-mC1 

Combined Sounder / Beacon

II 1G      Ex ia IIC T4 Ga (-40ºC <=Ta<= +60°C)

2813

SIRA 05ATEX2084X

Year / Ser. No. 

09 / 1MCR000001

Sounder Te w.r.t. Terminal -

Ui = 28V    Ii = 93mA    Pi = 660mW    Ci = 0     Li = 0   

    

Sounder Terminals S2&S3 w.r.t. Terminal -

Ui = 28V   Ii = 0mA   

www.e2s.com

Beacon Te w.r.t. Terminal -

Ui = 28V  Ii = 660mA  Pi = 1.2W  Ci = 0  Li = 0       

 

2) 

The  equipment  may  be  used  in  zones  0,  1  and  2 

with  flammable  gases  and  vapours  with  apparatus 

groups  IIA,  IIB  &  IIC and  with  temperature  classes 

T1, T2, T3 and T4. 

3) 

The  equipment  is  only  certified  for  use  in  ambient 

temperatures  in  the  range  -40

o

C  to  +60

o

C  and 

should not be used outside this range. 

 

4) 

The  certificate  number  has  an  ‘X’  suffix,  which 

indicates  that  the  certificate  contains  one  of  more 

special  conditions  for  safe  use.  Those  installing  or 

inspecting the equipment should refer to this section 

of the certificate. 

The IS-mC1 combined unit is CE 

marked for compliance with the 

European Explosive Atmospheres 

2014/34/EU and the European EMC 

Directive 2014/30/EU 

 

II 1G      Ex ia IIC T4 Ga (-40ºC <= Ta <= +60ºC) 

Содержание Minialert IS-mC1

Страница 1: ...but at supply voltages above 16V the internal current limit will function and therefore it is recommended that they are not operated continuously with a direct supply greater than 16V IS mC1 Sounder S...

Страница 2: ...e that the equipment is not installed in a location where it may be subjected to external conditions that might cause a build up of electrostatic charges on non conducting surfaces additionally cleani...

Страница 3: ...nd remove the sounder beacon section from the base by turning it anti clockwise Ensure that the O ring seal remains in place b Remove the required 20mm knockout section s depending on system wiring an...

Страница 4: ...meet the requirements for the sounder section see section 4 3 Hazardous Area IS mC1 Beacon IS mC1 Sounder 0V Power Supply Safe Area Barrier On Off 28V 93mA Positive Fig 7 Combined Unit wired for simu...

Страница 5: ...Intermittent 800Hz 0 25s ON 1s OFF Alternating 544Hz 100ms 440Hz 400ms NFS 32 001 Motor Siren Slow rise to 1200Hz Motor Siren Slow rise to 800Hz Continuous 1200Hz Motor Siren Slow rise to 2400Hz Inte...

Страница 6: ...rictive but care should be taken not to exceed a capacitive limit of 83nF for installations when very long cables are used 9 Volume Control The output level of the IS mC1 Combined Sounder Beacon can b...

Страница 7: ...ounder Terminal w r t Sounder Terminal from a barrier having a maximum open circuit voltage Uo that is 28V and a maximum short circuit current Io that is 93mA where Io is resistively limited If not al...

Страница 8: ...uoted and for which the output is non ignition capable for the Class Division or Zone and Group of use 7 The IS mC1 Combined Unit enclosure has an ingress protection rating of IP 65 If supplied withou...

Страница 9: ...ospheres disconnect power before servicing 8 Substitution of components may impair safety 9 The total capacitance connected to terminals of the sounder i e Ccable plus any other capacitance shall not...

Страница 10: ...2018 EN 60079 11 2012 IEC 60079 26 2014 Regulation EU No 305 2011 Construction Products Regulation CPR IS mA1 tones 2 3 9 15 16 17 only Notified Product Certification Body for Certificate of Constanc...

Страница 11: ...and Place of Issue London 23 12 2020 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the ma...

Страница 12: ...EU No 305 2011 Construction Products Regulation CPR IS mA1 tones 2 3 9 15 16 17 only Notified Product Certification Body for Certificate of Constancy of Performance or EC Type Examination Certificate...

Страница 13: ...and Place of Issue London 04 02 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the m...

Отзывы: