1600Hz

1400Hz

1s

0.5s

15) 

Tone Table

 

Tone Selection

 

– 

To select the required first stage tone set the tone switches 1 to 6 (see Fig 9) to the tone setting shown in the table below. The table also shows 

which 2

nd

, 3

rd

 and 4

th

 stage tones are available for use with the selected first stage tone if more than one tone output stage is required.

 

Stage 1 

Tone No 

Tone Description 

Tone Visual 

Switch Settings 

1 2 3 4 5 6

 

Stage 2 

Tone 

(S2) 

Stage 3 

Tone 

(S3) 

Stage 4 

Tone 

(S2 + S3) 

1000Hz PFEER Toxic Gas 

  

0 0 0 0 0 0 

44 

1200/500Hz @ 1Hz DIN / 
PFEER P.T.A.P. 

  

1 0 0 0 0 0 

44 

1000Hz @ 0.5Hz(1s on, 1s 
off) PFEER Gen. Alarm 

  

0 1 0 0 0 0 

44 

1.4KHz-1.6KHz 1s, 1.6KHz-
1.4KHz 0.5s NF C 48-265 

  

1 1 0 0 0 0 

44 

24 

544Hz(100mS)/440Hz 
(400mS) NF S 32-001 

  

0 0 1 0 0 0 

52 

19 

1500/500Hz - (0.5s on , 0.5s 
off) x3 + 1s gap AS4428 

  

1 0 1 0 0 0 

44 

500-1500Hz Sweeping 2 sec 
on 1 sec off AS4428 

  

0 1 1 0 0 0 

44 

500/1200Hz @ 0.26Hz(3.3s 
on, 0.5s off) Netherlands - 
NEN 2575 

  

1 1 1 0 0 0 

44 

24 

35 

1000Hz (1s on, 1s off)x7 + (7s 
on, 1s off) IMO Code 1a 

  

  

0 0 0 1 0 0 

18 

34 

10 

1000Hz (1s on, 1s off)x7 + (7s 
on, 1s off) IMO Code 1a 

1 0 0 1 0 0 

21 

34 

11 

420Hz(0.5s on, 0.5s off)x3 + 
1s gap ISO 8201 Temporal 
Pattern 

  

0 1 0 1 0 0 

44 

12 

1000Hz(0.5s on, 0.5s off)x3 + 
1s gap ISO 8201 Temporal 
Pattern 

  

1 1 0 1 0 0 

44 

13 

422/775Hz  -  (0.85 on, 0.5 
off) x3 + 1s gap NFPA - 
Temporal Coded 

  

0 0 1 1 0 0 

44 

14 

1000/2000Hz @ 1Hz 
Singapore 

  

1 0 1 1 0 0 

23 

35 

15 

300Hz Continuous 

  

0 1 1 1 0 0 

44 

24 

35 

16 

440Hz Continuous 

  

1 1 1 1 0 0 

44 

24 

35 

17 

470Hz Continuous 

  

0 0 0 0 1 0 

44 

24 

35 

18 

500Hz Continuous IMO code 
2 (Low) 

  

1 0 0 0 1 0 

44 

24 

35 

19 

554Hz Continuous 

  

0 1 0 0 1 0 

64 

24 

35 

20 

660Hz Continuous 

  

1 1 0 0 1 0 

44 

24 

35 

21 

800Hz IMO code 2 (High) 

  

0 0 1 0 1 0 

44 

24 

35 

22 

1200Hz Continuous 

  

1 0 1 0 1 0 

44 

24 

35 

23 

2000Hz Continuous 

  

0 1 1 0 1 0 

15 

35 

24 

2400Hz Continuous 

  

1 1 1 0 1 0 

48 

20 

35 

25 

440 @0.83Hz (50 
cycles/minute) Intermittent 

  

0 0 0 1 1 0  

44 

26 

470 @0.9Hz - 1.1s 
Intermittent 

  

1 0 0 1 1 0 

44 

27 

470Hz @5Hz - (5 
cycles/second) Intermittent 

  

0 1 0 1 1 0 

44 

28 

544Hz @ 1.14Hz - 0.875s 
Intermittent 

  

1 1 0 1 1 0 

44 

24 

29 

655Hz @ 0.875Hz 
Intermittent 

  

0 0 1 1 1 0 

44 

30 

660Hz @0.28Hz - 1.8sec on, 
1.8sec off Intermittent 

  

1 0 1 1 1 0 

44 

24 

31 

660Hz @3.34Hz - 150mS on, 
150mS off

 Intermittent

 

  

0 1 1 1 1 0 

30 

24 

1000Hz

 

1000Hz

1s

1s

544Hz

440Hz

0.1s

0.4s

1500Hz

500Hz

0.5s 0.5s

1.5s

0.5s 0.5s 0.5s

1500Hz

500Hz

2s

1s

1200Hz

500Hz

3.3s

0.5s

1s

1s

1s

7s

7s

1s

1s

1s

1s

1s

1s

1s

1000Hz 1s

1s

1s

1s

0.5s

0.5s

0.5s

1.5s

420Hz 0.5s

0.5s

1000Hz 0.5s

0.5s

0.5s

0.5s

0.5s

1.5s

775Hz

422Hz

0.85s

0.5s

0.85s

0.5s

0.85s

1.5s

2000Hz

1000Hz

1s

300Hz

 

440Hz

 

470Hz

 

500Hz

 

554Hz

 

660Hz

 

800Hz

 

1200Hz

 

2000Hz

 

2400Hz

 

440Hz

0.6s

0.6s

470Hz 0.55s

0.55s

470Hz 0.1s

0.1s

470Hz 0.43s

0.44s

655Hz 0.57s

0.57s

660Hz 1.8s

1.8s

660Hz 0.15s

0.15s

500Hz

1s

1200Hz

 

Содержание D2XC2XH1

Страница 1: ...and D2xC2XH2 are certified for use as public mode audible and visual alarm devices in accordance with UL1971 UL1638 UL464 See fire instructions D211 00 651 IS SC UL 3 2 ATEX IECEx UKEx certification S...

Страница 2: ...y Enclosure t Rating D2xC2XH1 Ex ec IIC T3 Gc X Ta 40 C to 50 C Ex tc IIIC T75 C Dc Ta 40 C to 50 C D2xC2XH2 Ex ec IIC T2 Gc X Ta 40 C to 50 C Ex tc IIIC T85 C Dc Ta 40 C to 50 C Installation must be...

Страница 3: ...ent is not to be mounted with the horn facing upwards Fig 1 Fixing locations 6 2 Access to the Enclosure Warning High voltage may be present risk of electric shock DO NOT open when energised disconnec...

Страница 4: ...user wishes to power the strobe separately For further wiring schematics refer to document D211 06 651 10 Earthing The unit has both internal and external earth points please see fig 2 fig 4 Internal...

Страница 5: ...the PCB The alarm horns can also be switched to sound the second third and fourth stage alarm tones The tone table shows the switch positions for the 64 tone and which tones are available for the seco...

Страница 6: ...22 Sheet 6 of 8 14 Electrical Ratings 14 1 Operating current Consumption Table 6 Electrical Ratings Model Nom Voltage Voltage Range Flash Rate Setting Max operating current D2xC2XH1DC024 24Vdc 20 28Vd...

Страница 7: ...s on 0 5s off x3 1s gap ISO 8201 Temporal Pattern 1 1 0 1 0 0 44 1 8 13 422 775Hz 0 85 on 0 5 off x3 1s gap NFPA Temporal Coded 0 0 1 1 0 0 44 1 8 14 1000 2000Hz 1Hz Singapore 1 0 1 1 0 0 23 3 35 15 3...

Страница 8: ...Hz Sweeping 1 0 0 0 1 1 44 24 12 51 600 1250Hz 0 125Hz Sweeping 0 1 0 0 1 1 44 24 12 52 660 1200Hz 1Hz Sweeping 1 1 0 0 1 1 64 24 12 53 800 1000Hz 1Hz Sweeping 0 0 1 0 1 1 56 24 12 54 800 1000Hz 7Hz S...

Страница 9: ...alarm use the temporal pattern tone No 12 as per the tone table provided in these instructions must be selected This tone produces a minimum sound pressure level of CAN ULC S525 100 4dB A at 10 feet...

Страница 10: ...Dispersion for wall mounting public mode 75 60 45 30 15 0 90 Fig 1 Vertical dispersion angles for wall mounting 55 45 8 18 60 40 7 27 65 35 6 36 70 35 6 36 75 30 5 45 80 30 5 45 85 25 4 55 90 25 4 55...

Страница 11: ...ght Output Dispersion for Wall Mounting Viewing Angle Of Rating Intensity cd at 1Hz flash rate 0 100 18 18 5 30 90 16 36 35 65 11 82 40 46 8 36 45 34 6 18 50 27 4 91 55 22 4 00 60 18 3 27 65 16 2 91 7...

Страница 12: ...fpm 2 28A 1 19A D2xC2XH2DC024 24Vdc 20 28Vdc 1Hz 60fpm 2 76A 1 35A 4 Sound Directional Characteristics for Canadian Fire CAN ULC S525 Horizontal Axis Angle OSPL Angle OSPL Reference 90 101 2 dB A Refe...

Страница 13: ...o Sounder ve ve Stage 2 Apply power to Sounder ve ve Connect Stage 2 to ve Stage 3 Apply power to Sounder ve ve Connect Stage 3 to ve Stage 4 Apply power to Sounder ve ve Connect Stage 2 and Stage 3 t...

Страница 14: ...herlands B V Utrechtseweg 310 6812 AR Arnhem Netherlands Quality Assurance Notification Module D SIRA 05 ATEX M342 Provisions fulfilled by the equipment II 3G Ex ec IIC T6 T4 T3 T2 T1 Gc II 3D Ex tc I...

Страница 15: ...e and Place of Issue London 22 08 2022 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the m...

Страница 16: ...Lane Eccleston Chester CH4 9JN UK Quality Assurance Notification Module D CSAE 22UKQAN0046 Provisions fulfilled by the equipment II 3G Ex ec IIC T6 T4 T3 T2 T1 Gc II 3D Ex tc IIIC Ex tc IIIC T55 75 80...

Страница 17: ...Place of Issue London 22 08 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the marke...

Отзывы: