001

-

IS

-

UL Issue B                          27/10/2021

 

 

FIRE INSTRUCTION & SERVICE MANUAL

 

D1xS Sounder UL464 / CAN/ULC

-

S525 Fire

 

Models: D1xS1

-

DC024

-

A. D1xS2

-

DC024

-

A,

 

D1xS1

-

DC024

-

S. D1xS2

-

DC024

-

S, 

 

 

 

• 

-

55°C to +85°C / 

-

67°F to +185°F

 

• 

Units can be mounted using at least 2 of the 3

-

off ø7mm holes in the mounting bracket.

 

• 

D1xS1RDC024

-

A & D1xS1RDC024

-

S are approved for use as an audible signal appliance for fire alarm use –

 

Public Mode (UL464 & 

CAN/ULC

-

S525) and produce a minimum sound pressure level of US: 81.62dB(A); CA: 84.8dB(A) at 10 feet, (figures @ worst case 

11.5Vdc).

 

• 

D1xS1RDC024

-

A & D1xS1RDC024

-

S produce a minimum sound pressure level of US: 83.4dB(A); CA: 86.4dB(A) at 10 feet (@24Vdc) 

 

• 

D1xS1FDC024

-

A & D1xS1FDC024

-

S are approved for use as an audible signal appliance for fire alarm use –

 

Public Mode (UL464 & 

CAN/ULC

-

S525) and produce a minimum sound pressure level of: US: 92.06dB(A); CA: 98.2dB(A) at 10 feet, (figures @ worst case 

11.5Vdc).

 

• 

D1xS1FDC024

-

A & D1xS1FDC024

-

S produce a minimum sound pressure level of: US: 94.62dB(A); CA: 100.9dB(A) at 10 feet 

(@24Vdc) 

 

• 

D1xS2FDC024

-

A & D1xS1FDC024

-

S are approved for use as an audible signal appliance for fire alarm use –

 

Public Mode (UL464 & 

CAN/ULC

-

S525) and produce a minimum sound pressure level of P1: US: 93.56dB(A) / P2: US: 94.9dB(A); CA: 101.6dB(A) / P3: US: 

95.51dB(A); CA: 101.8dB(A) at 10 feet, (figures @ worst case 11.5Vdc).

 

• 

D1xS2FDC024

-

A & D1xS2FDC024

-

S produce a minimum sound pressure level of P1: US: 95.64dB(A) / P2: US: 98.42dB(A); CA: 

105.2dB(A) / P3: US: 102.7dB(A); CA: 109.4dB(A) at 10 feet (@24Vdc) 

 

• 

D1xS2HDC024

-

A & D1xS2HDC024

-

S are approved for use as an audible signal appliance for fire alarm use –

 

Public Mode (UL464 & 

CAN/ULC

-

S525) and produce a minimum sound pressure level of P2: US: 95.51dB(A); CA: 103.8dB(A) / P3: US: 96.24dB(A); CA: 

105dB(A) at 10 feet, (figures @ worst case 11.5Vdc).

 

• 

D1xS2HDC024

-

A & D1xS2HDC024

-

S produce a minimum sound pressure level of P2: US: 100.2dB(A); CA: 108.5dB(A) / P3: US: 

103.5dB(A); CA: 111.6dB(A) at 10 feet (@24Vdc) 

 

• 

For Fire Alarm applications, the Sounder Volume must be at the highest setting, (see volume control section). For fire alarm use, Tone 

12 as shown below must be selected:

 

 

 

 

 

 

 

 

 

 

• 

Connection Terminals: Pluggable

 

 

 

AC: 1.0 

-

 2.5mm

2

 / AWG18 

-

 AWG12

 

                                  DC: 0.2 

-

 2.5mm

2

 / AWG24 

-

 AWG12

 

• 

Terminal Tightening torque 0.4Nm

 

• 

To maintain Ingress Protection, cable entries must be fitted with suitably rated cable glands or stopping plugs

 

• 

Units can be located indoor or outdoor wet use, wall or ceiling mounted and there are no limitations on orientation

 

• 

Factory finishes are not intended to be modified

 

Attention: Installation must be carried out by an electrician in compliance with the National Electrical Code, NFPA 70, and the National Fire Alarm 
Signaling Code, NFPA 72 or CSA 22.1 Canadian Electrical Code, Part I, Safety Standard for Electrical Installations, Section 32. /  L'installation doit 
exclusivement être réalisée par du personnel qualifié, conformément au code national d'électricité américain, NFPA 70, et le code national d

alarrme 

incendie et de signalisation NFPA 72 ou CSA 22.1 Code canadien de l'électricité, première partie, norme de sécurité relative aux installations électriques, 
Section 32

 

Attention: Disconnect from power source before installation or service to prevent electric shock / Débranchez

-

le de la source d'alimentation avant l'instal-

lation ou l'entretien pour éviter tout choc électrique.

 

Attention: Do not paint / Ne pas Peinturer

 

1000Hz(0.5s on, 0.5s off)x3 + 1s gap ISO 8201 Temporal 
Pattern

Stage 1
Set DIP
SW 1
Tone No.

Tone Description

Tone Visual

Stage 1 & 2
DIP SW 1/2

 Settings

1 2 3 4 5 6

Stage 3
Set DIP

SW 1

(S3)

Stage 4
Set DIP

SW 1

(S2 + S3)

12

1 1 0 1 0 0

1000Hz 0.5s

0.5s

0.5s

0.5s

0.5s

1s

1

8

Surge Current Ratings for use in fire alarm systems

 

Model

 

Nominal Voltage

 

Voltage Range

 

Initial Peak

 

Initial RMS

 

D1xS1

-

DC024

-

 

24V dc  

 

11.5 

-

 54V dc  

 

P1: 1312mA 

 

P1: 159mA 

 

D1xS1

-

DC024

-

S

 

P1: 1312mA 

 

P1: 159mA 

 

20 

-

 28V dc  

 

D1xS2

-

DC024

-

 

P2: 1005mA / P3: 1267mA

 

 P2: 286mA / P3: 553mA

 

11.5 

-

 54V dc  

 

D1xS2

-

DC024

-

 

20 

-

 28V dc  

 

P2: 1005mA / P3: 1267mA

 

 P2: 286mA / P3: 553mA

 

Содержание D1xS2FAC230-A

Страница 1: ...S ATMOSPHERES DISCONNECT FROM SUPPLY BEFORE OPENING KEEP TIGHTLY CLOSED WHEN IN OPERATION WARNING FIT SEALING FITTING IN CONDUIT RUNS WITHIN 18 INCHES FROM ENCLOSURE EQUIPMENT MUST NOT BE INSTALLED WI...

Страница 2: ...C Ex tb IIIC T95 C Db Ta 55 C to 75 C D1xS2 AC230 A Ex db IIC T5 Gb Ta 55 C to 75 C Ex db IIC T6 Gb Ta 55 C to 60 C Ex tb IIIC T93 C Db Ta 55 C to 75 C See Product table for electrical ratings of eac...

Страница 3: ...arges on non conducting surfaces Only the explosionproof cover is to be used for access to the enclosure for installation service and maintenance 6 Specific Conditions for Safe Use Flameproof threaded...

Страница 4: ...nd the length of the cable runs The cable size selected must have the necessary capacity to provide the input current to all the sounders connected to the line AC 1 0 2 5mm2 AWG18 AWG12 DC 0 2 2 5mm2...

Страница 5: ...ders See schematic diagram D190 06 001 for details 9 1 Configuration See Table 1 for product power supply and Sound Pressure Levels SPL Configuration for DC Units Fig 5 DC PCBA Configuration for AC Un...

Страница 6: ...iring options Config Voltage Configuration Description Features Product Option Identifier 1a DC Single Stage Configuration Line monitoring Positive Switching 1 1b DC Two Stage Configuration Common Neg...

Страница 7: ...f Line Monitoring An optional 12 way terminal module is available to enable up to four alarm stages to be activated from three DC voltage output channels The three alarm stage activation inputs can be...

Страница 8: ...ces may be fitted between the ve ve terminals of the PCBA Please ensure that the device legs meet the wire size range stated for the connection terminals and are fitted correctly in order to avoid a s...

Страница 9: ...0 0 0 1 0 1 0 0 0 0 1 1 0 0 0 1 1 1 0 0 0 0 0 0 1 0 0 1 0 0 1 0 0 0 1 0 1 0 0 1 1 0 1 0 0 0 0 1 1 0 0 1 0 1 1 0 0 0 1 1 1 0 0 1 1 1 1 0 0 0 0 0 0 1 0 1 0 0 0 1 0 0 1 0 0 1 0 1 1 0 0 1 0 0 0 1 0 1 0 1...

Страница 10: ...US 100 2dB A CA 108 5dB A P3 US 103 5dB A CA 111 6dB A at 10 feet 24Vdc For Fire Alarm applications the Sounder Volume must be at the highest setting see volume control section For fire alarm use Ton...

Страница 11: ...al Axis 3dB A 39 41 38 41 6dB A 45 47 64 69 D1xS2FDC024 A D1xS2FDC024 S Sounder Directional Characteristics for Canadian Fire CAN ULC S525 P3 OSPL Horizontal Axis Vertical Axis 3dB A 46 48 46 47 6dB A...

Страница 12: ...INE MONITORING RESISTOR CUSTOMER SUPPLIED 14V MAX SYSTEM 120 MIN 2W MIN OR 1K MIN 0 5W MIN 28V MAX SYSTEM 470 MIN 2W MIN OR 2 4K MIN 0 5W MIN RECOMMENDED MINIMUM VALUES R1 Stage 1 ve IN Stage 1 ve OUT...

Страница 13: ...n ve OUT Stage 1 ve OUT Stage 3 ve Stage 1 ve IN H2 H1 Stage 1 ve Stage 1 ve Stage 2 ve Stage 2 ve OF 2 3 R1 S2 S3 R1 S2 R2 OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUPPLIED 14V MAX SYSTEM 120 MIN 2...

Страница 14: ...er to Stage 2 ve Stage 2 ve Two Three Stage Voltage Free Activation Configuration Config 5 Customer Set H1 H2 to Negative Switching See Below Power ve ve Stage 1 Connect Stage 1 ve to Common ve Stage...

Страница 15: ...5 R S RAIT B ISARD R N POTTS OF NTS 1 SWITCHES FOR STAGE OPERATION CUSTOMER SUPPLIED 1 Earth Earth Stage 2 Stage 3 Common Live IN Live OUT Neutral IN Neutral OUT Earth Stage 1 Stage 2 Common N N L L E...

Страница 16: ...warden Industrial Park Hawarden Deeside CH5 3US UK Quality Assurance Notification Module D SIRA 05 ATEX M342 Provisions fulfilled by the equipment II 2G Ex db IIC T6 T3 GB II 2D Ex tb IIIC T82 C 145 C...

Страница 17: ...e and Place of Issue London 10 02 2022 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the m...

Страница 18: ...CH4 9JN UK Quality Assurance Notification Module D CSAE 22UKQAN0046 Provisions fulfilled by the equipment II 2G Ex db IIC T6 T3 GB II 2D Ex tb IIIC T82 C 145 C Db Standards applied EN 60079 0 2018 EN...

Страница 19: ...ate and Place of Issue London 24 02 2022 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the...

Страница 20: ...Page left Intentionally blank...

Отзывы: