9.4
Tone Selection
The D1x Alarm Horn Sounders have 64 different tones that can be
selected independently for the first and second stage alarms. The
tones are selected by operation of the tone setting DIP switch 1 & DIP
switch 2 (see fig 10) on the PCB, for stage 1 and stage 2 respectively.
Default = Switch 2
S2 - Tone 1
0 0 0 0 0 0
Default = Switch 1
S1 – Tone 44
1 1 0 1 0 1
(ON = 1, OFF = 0)
Fig 10: DIP switch configuration
The sounder can also be switched to sound the third and fourth stage
alarm tones.
The tone table (D221-95-001-IS) shows the switch positions for the 64
tones on first and second stages and which tones are available for the
third and fourth stages dependent on the Stage 1 DIP switch setting.
Following table (Table 3) is a summary of DC: D190-06-201; AC:
D190-06-205 wiring options.
Config.
Voltage Configuration
Description
Features
Product
Option
Identifier
1a/5a
DC
Single Stage Configuration
•
Line monitoring
•
Positive Switching
1
1b/5b
DC
Two Stage Configuration
•
Common Negative
•
Positive Switching
1
1c/5c
DC
Three/Four Stage Configuration
•
Common Negative
•
Positive Switching
1
2/6
DC
Three/Four Stages. Voltage Free 2nd, 3rd &
4th Stage Activation Configuration
•
Common Positive
•
Customer Set H1 & H2 to Negative
Switching
1
3/7
DC
Two Stage Configuration
•
Independent Stage Input
•
Reverse Polarity Stage Monitoring
1
4/8
DC
Two Stage Configuration
•
Line Stage Monitoring (Use suitable
monitoring relays/ modules)
•
Not to be used in reverse polarity
monitoring
Y
1a/2a
AC
Single Stage Configuration
•
1
1b/2b
AC
Three/Four Stage Configuration
1
Table 3: Summary of Wiring Options. See Document D190-06-301 for DC Schematic Diagrams; D190-06-305 for AC Schematic
Diagrams.