background image

 
 

E2S

 

Telephone:

 

+44

 

(0)20

 

8743

 

8880

 

Fax:

 

+44

 

(0)20

 

8740

 

4200

 

Email:

 

[email protected]

 

www.e2s.com

 

DC

067_Issue_H

 

(D1x).docx

 ‐ 

Page

 

1

 

of

 

2

 ‐ 

QAF_252_Issue_5

EU

 

Declaration

 

of

 

Conformity

 

Manufacturer:

   

European

 

Safety

 

Systems

 

Ltd.

 

Impress

 

House,

 

Mansell

 

Road,

 

Acton

 

London,

 

W3

 

7QH

 

United

 

Kingdom

 

Authorised

 

Representative:

 

E2S

 

Warnsignaltechnik

 

UG

 

Charlottenstrasse

 

45

51

 

72764

 

Reutlingen

 

Germany

 

Equipment

 

Type:

  

D1xS1,

 

D1xS2

 

D1xL1,

 

D1xL2

 

D1xC1X05,

 

D1xC1X10,

 

D1xC2X05,

 

D1xC2X10

 

D1xB2XH1,

 

D1xB2XH2

 

Directive

 

2014/34/EU:

 

Equipment

 

and

 

Protective

 

Systems

 

for

 

use

 

in

 

Potentially

 

Explosive

 

Atmospheres

 

(ATEX)

 ‐ 

D1xS1,

 

D1xS2,

 

D1xL1,

 

D1xL2,

 

D1xC1X05,

 

D1xC1X10,

 

D1xC2X05

 

and

 

D1xC2X10

 

only

 

Notified

 

Body

 

for

 

EU

 

type

 

Examination

 

(Module

 

B):

 

UL

 

International

 

Demko

 

A/S

 

Borupvang

 

5A

 

2750

 

Ballerup

 

Denmark

 

EU

type

 

Examination

 

Certificate

 

(Module

 

B):

 

DEMKO

 

19

 

ATEX

 

2141X

 

Notified

 

Body

 

for

 

Quality

 

Assurance

 

Notification

 

/

 

Conformity

 

to

 

EU

type

 

based

 

on

 

quality

 

assurance

 

of

 

the

 

production

 

process

 

(Module

 

D):

 

Sira

 

Certification

 

Service

 

Notified

 

Body

 

No.:

 

2813

 

Unit

 

6,

 

Hawarden

 

Industrial

 

Park,

 

Hawarden,

 

Deeside,

 

CH5

 

3US,

 

UK

 

Quality

 

Assurance

 

Notification

 

(Module

 

D):

 

SIRA

 

05

 

ATEX

 

M342

 

Provisions

 

fulfilled

 

by

 

the

 

equipment:

 

II

 

2G

 

Ex

 

db

 

IIC

 

T6…T3

 

GB

 

II

 

2D

 

Ex

 

tb

 

IIIC

 

T82

  ̊

C…145

  ̊

C

 

Db

 

Standards

 

applied:

 

EN

 

60079

0:2018

 

EN

 

60079

1:2014

 

EN60079

31:2014

 

Directive

 

2014/30/EU:

 

Electromagnetic

 

Compatibility

 

Directive

 

(EMC)

  

Standards

 

applied:

 

EN

 

61000

6

1:2007

 

EN

 

61000

6

2:2005

 

EN

 

61000

6

3:2007

 

/

 

A1:2011

 

/

 

AC:

 

2012

 

EN

 

61000

6

4:2007

 

/

 

A1:

 

2011

 

Directive

 

2014/35/EU:

 

Low

 

Voltage

 

Directive

 

(LVD)

 

Standards

 

applied:

 

EN

 

60947

1:2007

 

+

 

A2:2014

 

Directive

 

2011/65/EU:

 

Restriction

 

of

 

the

 

use

 

of

 

certain

 

hazardous

 

substances

 

in

 

electrical

 

and

 

electronic

 

equipment

 

(RoHS)

 

The

 

product

 

and

 

all

 

the

 

components

 

contained

 

within

 

it

 

are

 

in

 

accordance

 

with

 

the

 

restriction

 

of

 

the

 

use

 

of

 

hazardous

 

substances

 

in

 

electrical

 

and

 

electronic

 

equipment,

 

including

 

amendment

 

by

 

Directive

 

2015/863/EU.

Regulation

 

(EC)

 

1907/2006:

 

Registration,

 

Evaluation,

 

Authorisation

 

and

 

Restriction

 

of

 

Chemicals

 

(REACH)

 

The

 

product

 

and

 

all

 

the

 

components

 

contained

 

within

 

it

 

are

 

free

 

from

 

substances

 

of

 

very

 

high

 

concern.

 

Other

 

Standards

 

and

 

Regulations

 

EN

 

60529:1992+A2:2013

 ‐ 

Degrees

 

of

 

protection

 

provided

 

by

 

enclosures

 

(IP

 

code)

 

 

enclosure

 

rated

 

IP66

 

Содержание D1xC1 Series

Страница 1: ... 317mA 110 120Vac 50 60Hz D1xC1X10FAC230 A 230Vac 169mA 220 240Vac 50 60Hz D1XC2X05RDC024 A 24Vdc P2 P3 647 1063mA 20 28Vdc P2 P3 112 114 P2 P3 107 109 D1xC2X05RAC115 A 115Vac P2 P3 255 415mA 110 120Vac 50 60Hz D1xC2X05RAC230 A 230Vac P2 P3 157 246mA 220 240Vac 50 60Hz D1XC2X05DC024 A 24Vdc P2 P3 647 1063mA 20 28Vdc P2 P3 120 123 P2 P3 115 118 D1xC2X05FAC115 A 115Vac P2 P3 255 415mA 110 120Vac 50 ...

Страница 2: ...4A Ta 55 C to 50 C Class Division Ratings for Canada CEC Model No Rating D1xC1X05 DC024 A D1xC2X05 DC024 A Class I Div 1 ABCD T5 Ta 55 C to 55 C Class I Div 1 ABCD T6 Ta 55 C to 45 C D1xC1X10 DC024 A D1xC2X10 DC024 A Class I Div 1 ABCD T4A Ta 55 C to 55 C Class Zone Ratings for US NEC Model No Rating D1xC1X05 DC024 A D1xC2X05 DC024 A Class I Zone 1 IIC T4 Ta 55 C to 85 C Class I Zone 1 IIC T4A Ta ...

Страница 3: ...Explosive dust air mixture not likely to occur in normal operation and if it does it will only exist for a short time Dust Groupings Group IIIA Combustible Dusts Group IIIB Non Conductive Dusts Group IIIC Conductive Dusts Equipment Category 2G 2D Equipment Protection Level Gb Gc Db Dc Maximum Surface Temperature for Dust Applications 115ºC D1xC1X05 DC024 A D1xC2X05 DC024 A 122ºC D1xC1X05 AC115 A D...

Страница 4: ...d maintenance 6 Specific Conditions for Safe Use Flameproof threaded joints and cemented joints are not permitted to be repaired 7 Product Mounting and Access 7 1 Mounting 30 1 18 in 117 3 4 62 in 30 1 18 in 338 6 13 33 in 145 5 71 in 30 1 18 in 186 5 7 34 in 30 1 18 in 145 5 71 in 181 64 7 15 in 30 1 18 in 236 9 9 33 in 30 1 18 in 145 5 71 in 219 6 8 64 in 407 8 16 06 in 458 2 18 04 in 122 4 80 i...

Страница 5: ... selected must have the necessary capacity to provide the input current to all the sounders connected to the line AC 1 0 2 5mm2 AWG18 AWG12 DC 0 2 2 5mm2 AWG24 AWG12 Figure 3 Wire Preparation When connecting wires to the terminals great care should be taken to dress the wires so that when the cover is inserted into the chamber the wires do not exert excess pressure on the terminal blocks This is p...

Страница 6: ...SPL Configuration for DC Units Figure 6 DC PCBA Configuration for AC Units Figure 7 AC PCBA Switching from positive switching default to negative switching DC Only NOTE Max supply is 33V DC if higher DC voltage is required use Negative switching Figure 8 Stage Switching Polarity 9 3 Flash Rate Settings DC Flash Settings AC Flash Settings Flip Flop Mode not available on D1xC1X05 D1xC2X05 Figure 9 A...

Страница 7: ...rth stages dependent on the Stage 1 DIP switch setting Following table Table 3 is a summary of DC D190 06 201 AC D190 06 205 wiring options Config Voltage Configuration Description Features Product Option Identifier 1a 5a DC Single Stage Configuration Line monitoring Positive Switching 1 1b 5b DC Two Stage Configuration Common Negative Positive Switching 1 1c 5c DC Three Four Stage Configuration C...

Страница 8: ... directly across the ve and ve terminals as shown in the following drawing The resistor leads should be kept as short as possible See D190 06 001 for details Figure 11 End of Line Resistor placement 11 Maintenance Overhaul and Repair Maintenance repair and overhaul of the equipment should only be carried out by suitably qualified personnel in accordance with the current relevant standards For ATEx...

Страница 9: ...ngs Model Nominal Voltage Voltage Range Nom RMS Current Beacon Nom RMS Current Sounder Nom RMS Current Combined Max RMS Current Combined D1xC1X05 DC024 A 24V dc 20 28V dc 323mA 185mA 508mA 555mA 20Vdc D1xC1X05 AC115 A 115V ac 110 120V ac 50 60Hz 130mA 70mA 200mA 264mA 120Vac 60Hz D1xC1X05 AC230 A 230V ac 220 240V ac 50 60Hz 79mA 48mA 127mA 149mA 240Vac 60Hz D1xC1X10 DC024 A 24V dc 20 28V dc 673mA ...

Страница 10: ...Nm To maintain Ingress Protection cable entries must be fitted with suitably rated cable glands or stopping plugs Units can be located indoor or outdoor wet use wall or ceiling mounted and there are no limitations on orientation Factory finishes are not intended to be modified For private mode fire alarm use the beacons must be set to the certified flash patterns of 1Hz For light output ratings se...

Страница 11: ...xC1X10FDC024 A Sounder Direc tional Characteristics for Canadian Fire CAN ULC S525 OSPL Horizontal Axis Vertical Axis 3dB A 39 41 38 41 6dB A 45 47 64 69 D1xC2X05FDC024 A D1xC2X10FDC024 A Sounder Direc tional Characteristics for Canadian Fire CAN ULC S525 P3 OSPL Horizontal Axis Vertical Axis 3dB A 46 48 46 47 6dB A 52 54 52 53 D1xC1X05RDC024 A D1xC1X10RDC024 A Sounder Direc tional Characteristics...

Страница 12: ... 0 0 0 1 0 1 0 0 0 0 1 1 0 0 0 1 1 1 0 0 0 0 0 0 1 0 0 1 0 0 1 0 0 0 1 0 1 0 0 1 1 0 1 0 0 0 0 1 1 0 0 1 0 1 1 0 0 0 1 1 1 0 0 1 1 1 1 0 0 0 0 0 0 1 0 1 0 0 0 1 0 0 1 0 0 1 0 1 1 0 0 1 0 0 0 1 0 1 0 1 0 1 0 1 0 0 1 1 0 1 0 1 1 1 0 1 0 1 1 0 1 1 0 0 0 1 1 1 0 0 1 1 1 1 0 0 0 0 0 0 1 0 1 0 0 0 1 1 1 0 0 0 1 0 0 1 0 0 1 1 0 1 0 0 1 0 1 1 0 0 1 1 1 1 0 0 1 0 0 0 1 0 1 0 1 0 1 0 1 1 0 1 1 0 1 0 1 1 1 0...

Страница 13: ...ge 1 ve IN Stage 1 ve OUT Common ve IN Common ve OUT Stage 2 ve Stage 3 ve WIRING LINKING BEACON SOUNDER FACTORY FITTED 6 R1 R1 S2 S3 R1 S2 OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUPPLIED 14V MAX SYSTEM 120Ω MIN 2W MIN OR 1KΩ MIN 0 5W MIN 28V MAX SYSTEM 470Ω MIN 2W MIN OR 2 4KΩ MIN 0 5W MIN RECOMMENDED MINIMUM VALUES R1 Stage 1 ve IN Stage 1 ve OUT Stage 1 ve IN Stage 1 ve OUT Single Stage Con...

Страница 14: ...D D190 06 301 6 S2 S3 R1 S2 R2 OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUPPLIED 14V MAX SYSTEM 120Ω MIN 2W MIN OR 1KΩ MIN 0 5W MIN 28V MAX SYSTEM 470Ω MIN 2W MIN OR 2 4KΩ MIN 0 5W MIN RECOMMENDED MINIMUM VALUES R1 Three Four Stages Voltage Free 2nd 3rd 4th Stage Activation Configuration Config 2 Common Positive Customer Set H1 H2 to Negative Switching See Below Stage 1 Apply Power to Common ve ...

Страница 15: ...DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B R S RAIT B ISARD R N POTTS NTS OF 3 SWITCHES FOR STAGE OPERATION CUSTOMER SUPPLIED D190 06 301 6 WIRING LINKING BEACON SOUNDER FACTORY FITTED OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUPPLIED 14V MAX SYSTEM 120Ω MIN 2W MIN OR 1KΩ MIN 0 5W MIN 28V MAX SYSTEM 470Ω MIN 2W MIN OR 2 4KΩ MIN 0 5W MIN RECOMMENDED MINIMUM V...

Страница 16: ... Stage 2 ve Stage 1 ve IN Stage 1 ve OUT Common ve IN Common ve OUT Stage 2 ve Stage 3 ve ve IN ve IN D190 06 301 6 4 R2 ve OUT ve OUT R1 R1 S2 R1 S2 S3 OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUPPLIED 14V MAX SYSTEM 120Ω MIN 2W MIN OR 1KΩ MIN 0 5W MIN 28V MAX SYSTEM 470Ω MIN 2W MIN OR 2 4KΩ MIN 0 5W MIN RECOMMENDED MINIMUM VALUES R1 Single Stage Configuration Config 5a Line Monitoring Set to p...

Страница 17: ...2 R1 OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUPPLIED 14V MAX SYSTEM 120Ω MIN 2W MIN OR 1KΩ MIN 0 5W MIN 28V MAX SYSTEM 470Ω MIN 2W MIN OR 2 4KΩ MIN 0 5W MIN RECOMMENDED MINIMUM VALUES R1 Three Four Stages Voltage Free 2nd 3rd 4th Stage Activation Configuration Config 6 Common Positive Customer Set H1 H2 to Negative Switching See Below Stage 1 Apply Power to Common ve Stage 1 ve Stage 2 Apply P...

Страница 18: ...DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B R S RAIT B ISARD R N POTTS NTS OF SWITCHES FOR STAGE OPERATION CUSTOMER SUPPLIED D190 06 301 6 6 OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUPPLIED 14V MAX SYSTEM 120Ω MIN 2W MIN OR 1KΩ MIN 0 5W MIN 28V MAX SYSTEM 470Ω MIN 2W MIN OR 2 4KΩ MIN 0 5W MIN RECOMMENDED MINIMUM VALUES R1 Independent Sounder Beacon Activatio...

Страница 19: ...L SHEET SCALE TITLE A3 IF IN DOUBT ASK DO NOT SCALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D190 06 305 R S RAIT B ISARD R N POTTS OF NTS 1 SWITCHES FOR STAGE OPERATION CUSTOMER SUPPLIED WIRING LINKING BEACON SOUNDER FACTORY FITTED 2 Earth Earth Stage 2 Stage 3 Common L N L N N N L L E N N L L E C S2 S3 Live IN Live OUT Neutral IN Neutral OUT Stage 1 Li...

Страница 20: ...SCALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D190 06 305 R S RAIT B ISARD R N POTTS OF NTS 2 SWITCHES FOR STAGE OPERATION CUSTOMER SUPPLIED 2 Stage 1 Live IN Stage 1 Live OUT Stage 1 Neutral IN Stage 1 Neutral OUT Earth Live IN Live OUT Neutral IN Neutral OUT Earth Stage 2 Stage 3 Common N N L L E N N L L E C S2 S3 Single Stage Configuration Config 2a ...

Страница 21: ...awarden Industrial Park Hawarden Deeside CH5 3US UK Quality Assurance Notification Module D SIRA 05 ATEX M342 Provisions fulfilled by the equipment II 2G Ex db IIC T6 T3 GB II 2D Ex tb IIIC T82 C 145 C Db Standards applied EN 60079 0 2018 EN 60079 1 2014 EN60079 31 2014 Directive 2014 30 EU Electromagnetic Compatibility Directive EMC Standards applied EN 61000 6 1 2007 EN 61000 6 2 2005 EN 61000 6...

Страница 22: ...te and Place of Issue London 10 02 2022 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the market the equipment conforms with all technical and regulatory requirements of the above listed directives regulations and standards This Declaration is issued under the sole responsibility of the ma...

Страница 23: ... CH4 9JN UK Quality Assurance Notification Module D CSAE 22UKQAN0046 Provisions fulfilled by the equipment II 2G Ex db IIC T6 T3 GB II 2D Ex tb IIIC T82 C 145 C Db Standards applied EN 60079 0 2018 EN 60079 1 2014 EN60079 31 2014 Directive 2014 30 EU Electromagnetic Compatibility Directive EMC Standards applied EN 61000 6 1 2007 EN 61000 6 2 2005 EN 61000 6 3 2007 A1 2011 AC 2012 EN 61000 6 4 2007...

Страница 24: ...Date and Place of Issue London 24 02 2022 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the market the equipment conforms with all technical and regulatory requirements of the above listed directives regulations and standards This Declaration is issued under the sole responsibility of the ...

Отзывы: