BExL15D  

100V Line 

15W 

 

100V 

BExL15D  

70V Line   

15W 

 

70V 

BExL15D  

8 ohm 

 

15W 

 

10.95V 

BExL15D  

16 ohm   

15W 

 

15.49V 

 

The above table also shows the maximum AC signal voltages 

at which the loudspeakers can be operated. 
 

The current levels taken by the each loudspeaker will depend 
on which output tapping has been selected (see section 13 of 

this  instruction  manual).  BExL25D  100V  &  70V  Line  units 
have  output  levels  of  25W,  12.5W,  6W  and  2W,  BExL15D 
100V & 70V Line units have output levels of 15W, 7.5W, 3W 

and 1W. 
 

10) Cable Selection 
 

Cables must be capable of handling the current drawn from 
all of the units on the line. 

 
SAFETY  WARNING:  If  the  high  output  BExL25D 

loudspeakers  are  used  at  high  ambient  temperatures,  i.e. 
over  +40ºC,  then  the  cable  entry  temperature  may  exceed 

+70ºC  and  therefore  suitable  heat  resisting  cables  must be 
used, with a rated service temperature of at least 110ºC. 
 

11)  Earthing

 

 

Loudspeakers  units  must  be  connected  to  a  good  quality 
earth.  The  units  are  provided  with  internal  and  external-

earthing  terminals,  which  are,  both  located  on  the  terminal 
chamber section of the unit (see figures 2 and 3).  

 
When using the internal earth terminal ensure that the 

stainless steel M4 flat washer is between the incoming earth 
wire and the enclosure. 
 

When using the external earth terminal a cable crimp lug 
must be used.  The cable lug should be located between the 

two M5 stainless steel flat washers. The M5 stainless steel 
spring washer must be fixed between the outer flat washer 

and the M5 stainless steel nut to ensure that the cable lug is 
secured against loosening and twisting.  

 

12)  Cable Glands

 

 

The  sounders  have  dual  cable  gland  entries  with  M20  x1.5 
entry  threads.  Only  cable  glands  approved  for  Ex  ‘d’ 

applications can be used, which must be suitable for the type 
of cable being used and also meet the requirements of the Ex 

‘d’  flameproof  installation  standard  EN60079-14:2008  / 
IEC60079-14:2007. 

 
SAFETY  WARNING:  If  the  high  output  BExL25D 

loudspeakers  are  used  at  high  ambient  temperatures,  i.e. 
over  +40ºC,  then  the  cable  entry  temperature  may  exceed 
+70ºC  and  therefore  suitable  heat  resisting  cable  glands 

must  be  used,  with  a  rated  service  temperature  of  at  least 
110ºC. 

 
If  a  high  IP  (Ingress  Protection)  rating  is  required  then  a 

suitable sealing washer must be fitted under the cable gland.  
 

When  only  one  cable  entry  is  used  the  other  one  must  be 
closed with an Ex ‘d’ flameproof blanking plug, which must be 
suitably approved for the installation requirements.  

 
 

 

 

13)  Cable Connections 
 

Terminals 

BExL25D (25W)         BExL15D (15W) 

 
A - B 

 

     25W   

 

15W 

A - C 

 

     12.5W 

 

7.5W 

A - D 

 

     6W   

 

3W 

A - E 

 

     2W   

 

1W 

 

See drawings C and D / wiring diagram E 
 

 

14)  End of Line DC Monitoring 

 

 

On BExL25D and BExL15D loudspeakers, dc line monitoring 

can be used if required. Both the 100V & 70V Line units and 
the Low Impedance units have a blocking capacitor fitted. It 

should be noted that each loudspeaker has a 1M ohm bleed 
resistor  connected  across  the  blocking  capacitor  and  this 

should be taken into account when selecting the value of the 
end of line monitoring resistance. 
 

The end of line monitoring resistor can be connected across 
the terminals on the end of line unit. On  the low impedance 

units  care  must  be  taken  with  the  polarity  of  the  monitoring 
voltage. 

 
On 100V and 70V line units the end of line resistor used must 

have  a  minimum  resistance  value  of  4k7  ohms  and  a 
minimum wattage of 2.5 watts 
 

On  low  impedance  units  the  end  of  line  resistor  used  must 
have a minimum resistance value of 2k ohms and a minimum 

wattage  of  0.5  watts  or  a  minimum  resistance  value  of 500 
ohms  and  a  minimum  wattage  of  2  watts.  On  the  low 

impedance  units  care  must be  taken  with  the  polarity  of  the 
monitoring voltage. If an end of line resistor is fitted to a unit 

the  links  on  the  printed  circuit  boards  of  all  loudspeakers  in 
the  line  must  be cut  for  the  dc  blocking capacitors  to  be  in 
circuit in order to dc monitor the line (see figure 5). 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

Содержание BExL25D

Страница 1: ...C Year of Construction Serial No i e 10 1L23000001 3 Type Approval Standards The loudspeakers have EC Type Examination and IECEx certificates issued by KEMA and have been approved to the following st...

Страница 2: ...n place W hen replacing the flameproof cover casting ensure that it is square with the flameproof chamber casting before inserting Carefully push the cover in place allowing time for the air to be exp...

Страница 3: ...hen the cable entry temperature may exceed 70 C and therefore suitable heat resisting cable glands must be used with a rated service temperature of at least 110 C If a high IP Ingress Protection ratin...

Страница 4: ...citor and this should be taken into account when selecting the value of the end of line monitoring resistance The end of line monitoring resistor can be connected across the terminals on the end of li...

Страница 5: ...y to occur and if it does it will only exist for a short time Gas Groupings Group IIA Propane Group IIB Ethylene Group IIC Up to 55 C only Hydrogen and Acetylene Equipment Category 2G Temperature Clas...

Страница 6: ...ds Only cable glands approved for Ex d applications can be used which must be suitable for the type of cable being used and also meet the requirements of the Ex d flameproof installation standard EN60...

Страница 7: ...roef aandraaien om vast te zetten Serrer la vis pour une fixation s re Zum Sichern Schraube anziehen Stringere la vite per il fissaggio Stram skruen for feste Aperte o parafuso para fixar Apriete el t...

Страница 8: ...td Impress House Mansell Road Acton London W3 7QH sales e 2 s com Tel 44 0 208 743 8880 www e 2 s com Fax 44 0 208 740 4200 Document No BExL25D and BExL15D English Issue E Four Sheets 12 02 10 8 Wirin...

Страница 9: ...synligvis ikke og hvis det sker vil det kun v re for en kort tidsperiode Gasgrupperinger Gruppe IIA Propan Gruppe IIB Ethylen Gruppe IIC 55 C Hydrogen og acetylen Udstyrskategori 2G Temperaturklassifi...

Страница 10: ...es samt opfylde kravene i Ex d standard for flammesikker installation EN60079 14 2008 IEC60079 14 2007 SIKKERHEDSADVARSEL Hvis de h jtydende BExL25D h jttaler anvendes ved h je omgivende temperaturer...

Страница 11: ...2 Ontplofbaar gas luchtmengsel is onwaarschijnlijk en indien dit ontstaat zal het waarschijnlijk slechts korte tijd aanwezig blijven Gasgroeperingen Groep IIA Propaan Groep IIB Ethyleen Groep IIC 55 C...

Страница 12: ...rtels worden gebruikt die zijn goedgekeurd voor Ex d toepassingen geschikt zijn voor het bekabelingstype dat wordt gebruikt en voldoen aan de vereisten van de norm EN60079 14 2008 IEC60079 14 2007 ten...

Страница 13: ...normale Zone 2 M lange d air et de gaz explosif ne pouvant pas survenir et qui dans le cas contraire serait pr sent que tr s bri vement Groupes de gaz Groupe IIA Propane Groupe IIB Ethyl ne Groupe IIC...

Страница 14: ...cations Ex d peuvent tre utilis s et ils doivent tre ad quats pour le type de c ble utilis et r pondre aux exigences d installation d antid flagrant Ex d de norme EN60079 14 2008 IEC60079 14 2007 AVER...

Страница 15: ...Luft Mischung vorliegen Zone 2 Explosive Gas Luft Mischung unwahrschein lich und sollte sie doch auftreten dann nur kurzfristig Gasgruppen Gruppe IIA Propan Gruppe IIB thylen Gruppe IIC 55 C Wasserst...

Страница 16: ...abeltyp geeignet sein und zudem den Anforderungen der Ex d Norm zur Installation schwer entflammbarer Ger te EN60079 14 2008 IEC60079 14 2007 entsprechen SICHERHEITSHINWEIS Wenn die BExL25D High Outpu...

Страница 17: ...esplosivo durante il normale funzionamento Zona 2 Non probabile che sia presente gas esplosivo e se esso dovesse essere presente potr esserlo solo per un breve periodo di tempo Gruppi di gas Gruppo I...

Страница 18: ...ngressi per premistoppa con filettature M20 x1 5 Utilizzare solo premistoppa approvati per le applicazioni Ex d essi inoltre devono essere adeguati al tipo di cavo in uso e devono rispettare gli stand...

Страница 19: ...losiv gass luft blanding som ikke vanligvis vil forekomme og om den gj r det kun vil forekomme i kort tid Gassgrupperinger Gruppe IIA Propan Gruppe IIB Etylen Gruppe IIC 55 C Hydrogen og acetylen Utst...

Страница 20: ...elmuffer godkjent for Ex d bruk kan brukes og de m v re egnet for typen kabel som brukes samt overholde kravene i standarden for Ex d flammesikker installering EN60079 14 2003 IEC60079 14 2007 SIKKERH...

Страница 21: ...va em funcionamento normal Zona 2 Improbabilidade de ocorr ncia de mistura gasosa explosiva mesmo que tal ocorra s ser por per odo curto Grupos de gases Grupo IIA Propano Grupo IIB Etileno Grupo IIC 5...

Страница 22: ...ara aplica es prova de explos o que devem ser adequados ao tipo de cabo a ser usado e satisfazer tamb m os requisitos da norma EN60079 14 2008 IEC60079 14 2007 relativa instala o prova de fogo e de ex...

Страница 23: ...s posible ocurra durante el funcionamiento normal Zona 2 Mezcla explosiva improbable de aire y gas que de producirse lo har s lo por breve tiempo Grupos de gas Grupo IIA Propano Grupo IIB Etileno Grup...

Страница 24: ...cable aprobados para aplicaciones Ex d los cuales deben ser adecuados para el tipo de cable que se est utilizando adem s de satisfacer los requisitos de la norma EN 60079 14 2008 IEC60079 14 2007 para...

Страница 25: ...al drift Zon 2 Explosiv gasblandning f rv ntas f rekomma s llan och d endast kortvarigt Explosionsgrupper Grupp IIA Propan Grupp IIB Etylen Grupp IIC 55 C V te och acetylen Kategori p utrustning 2G T...

Страница 26: ...kabeling ngar med M20 x 1 5 g nga Endast kabelgenomf ringar godk nda f r Ex d bruk f r anv ndas Dessa m ste passa den typ av kabel som anv nds och dessutom uppfylla kraven f r explosionst t kapsling E...

Страница 27: ...004 Directive 89 106 EEC Construction Products Directive CPD BExS110D24DC BExS120D24DC tones 2 3 9 15 16 17 only Notified Body for EC type Examination VdS Schadensverh tung GmbH Notified Body No 0786...

Отзывы: