Document No. IS 2423-P        Issue G     12-02-10                              Sheet 1 of  4                                                                                               (1) 

 

INSTRUCTION MANUAL  (ATEX / IECEx) 

BExL25D and BExL15D   

Flameproof Loudspeakers

 

 
 
 
 
1) Introduction 

 
The  BExL25D  and  BExL15D  are  flameproof  loudspeakers 
which  are  certified  to  meet  the  requirements  of  the  ATEX 
directive  94/9/EC  and  the  IECEx  scheme.  The  loudspeakers 

can  be used  in hazardous  areas where  potentially flammable 
atmospheres may be present. There are four versions of each 
loudspeaker,  8  ohm  or  16  ohm  and  70V  or  100V  Line 
transformer. On 70V and 100V line transformer units there are 
four  output  tappings  for  each  size  of  loudspeaker.  The 

BExL25D  unit  produces output  levels  in  the  117dB(A)  range 
and the BExL15D unit produces output levels in the 112dB(A) 

range. Both loudspeakers can be used in Zone 1 and Zone 2 
areas  with  gases  in groups  IIA, IIB  and  IIC  and  temperature 
Classifications of T1, T2, T3 and T4. For ambient temperatures 
over +55ºC the gas groups are limited to IIA and IIB. 

 

2)  

Marking

 

 
All  units  have  a  rating  label,  which  carries  the  following 

important information:- 
 
Unit Type No.     

BExL25D   or   BExL15D

 

 

Impedance:        8 ohm or 16 ohm   

            70V Line or 100V Line 

 
Codes:           

Ex d IIC T4 for Ta –50°C to +55°C 

       Ex d IIB T4 for Ta –50°C to +70°C 

 

Certificate No’s

    KEMA 99ATEX6312 

IECEx KEM 10.0003

 

 

        

 

 

 

 
 

“Warnings”

 

 DO NOT OPEN WHEN AN EXPLOSIVE  

                         

     GAS ATMOSPHERE IS PRESENT 

 

      COVER BOLTS CLASS A4-80 
 

   USE HEAT RESISTING CABLES AND CABLE GLANDS 

 

       (Rated 110ºC) AT AMB. TEMPERATURES OVER 40ºC 

 
Year of Construction /  
Serial No.      

 

 i.e.   10 / 1L23000001

 

 

3) 

Type Approval Standards

 

 

The  loudspeakers  have  EC  Type  Examination  and  IECEx 
certificates issued  by  KEMA and have  been  approved to  the 

following standards:- 
 

 
 
 

 
 

 

EN60079-0:2006   IEC60079-0:2004 (Ed4)

      

General Requirements

 

EN60079-1:2007   IEC60079-1:2007

 

(Ed6)

        Flameproof Enclosure ‘d’ 

 

4) 

Installation Requirements

 

 

The  loudspeakers  must  be  installed  in  accordance  with  the 
latest issues of the relevant parts of the EN60079 standards or 

the  equivalent  IEC  standards  –  Selection,  Installation  and 
maintenance  of  electrical  apparatus  for  use  in  potentially 

explosive  atmospheres  (other  than  mining  applications  or 
explosive processing and manufacture):- 

 
EN60079-14:2008

    

Electrical Installations in Hazardous 

IEC60079-14:2007 (Ed4) 

Areas (other than mines)

 

 
EN60079-10:2003

   

Classification of Hazardous Areas

 

IEC60079-10:2008 (Ed1) 
 
The  installation of  the  units  must also  be in  accordance  with 
any local codes that may apply and should only be carried out 
by a competent electrical engineer who has had the necessary 
training. 

 

5) 

Zones,  Gas  Group,  Category  and  Temperature 
Classification 

 

The BExL25D and BExL15D loudspeakers have been certified 
Ex d IIC T4 for Ta –50°C to +55ºC) and Ex d IIB T4 for Ta –
50°C to +70ºC). This means that the units can be installed in 
locations with the following conditions:- 
 

Area Classification: 

 

Zone 1 

Explosive  gas  air  mixture  likely  to  occur  in 
normal operation. 

Zone 2 

Explosive  gas  air  mixture  not  likely  to  occur, 
and if it does, it will only exist for a short time. 

  

Gas Groupings: 

 

Group IIA 

Propane 

Group IIB 

Ethylene 

Group IIC (Up to +55ºC only)  Hydrogen and Acetylene 

 

 

Equipment Category: 

2G 

 

Temperature Classification: 

 

T1 

400

o

 C  

T2 

300

o

 C 

T3 

200

o

 C 

T4 

135

o

 C 

 

Ambient Temperature Range: 

    

-50

°

C to +55

°

C

 

Gas Groups IIA, IIB and IIC 

-50

°

C to +70

°

C Gas Groups IIA and IIB 

 

0518 

II 2G 

Epsilon x: 

Equipment Group  
and Category: 

CE Marking: 
Notified Body No. 

 

Содержание BExL25D

Страница 1: ...C Year of Construction Serial No i e 10 1L23000001 3 Type Approval Standards The loudspeakers have EC Type Examination and IECEx certificates issued by KEMA and have been approved to the following st...

Страница 2: ...n place W hen replacing the flameproof cover casting ensure that it is square with the flameproof chamber casting before inserting Carefully push the cover in place allowing time for the air to be exp...

Страница 3: ...hen the cable entry temperature may exceed 70 C and therefore suitable heat resisting cable glands must be used with a rated service temperature of at least 110 C If a high IP Ingress Protection ratin...

Страница 4: ...citor and this should be taken into account when selecting the value of the end of line monitoring resistance The end of line monitoring resistor can be connected across the terminals on the end of li...

Страница 5: ...y to occur and if it does it will only exist for a short time Gas Groupings Group IIA Propane Group IIB Ethylene Group IIC Up to 55 C only Hydrogen and Acetylene Equipment Category 2G Temperature Clas...

Страница 6: ...ds Only cable glands approved for Ex d applications can be used which must be suitable for the type of cable being used and also meet the requirements of the Ex d flameproof installation standard EN60...

Страница 7: ...roef aandraaien om vast te zetten Serrer la vis pour une fixation s re Zum Sichern Schraube anziehen Stringere la vite per il fissaggio Stram skruen for feste Aperte o parafuso para fixar Apriete el t...

Страница 8: ...td Impress House Mansell Road Acton London W3 7QH sales e 2 s com Tel 44 0 208 743 8880 www e 2 s com Fax 44 0 208 740 4200 Document No BExL25D and BExL15D English Issue E Four Sheets 12 02 10 8 Wirin...

Страница 9: ...synligvis ikke og hvis det sker vil det kun v re for en kort tidsperiode Gasgrupperinger Gruppe IIA Propan Gruppe IIB Ethylen Gruppe IIC 55 C Hydrogen og acetylen Udstyrskategori 2G Temperaturklassifi...

Страница 10: ...es samt opfylde kravene i Ex d standard for flammesikker installation EN60079 14 2008 IEC60079 14 2007 SIKKERHEDSADVARSEL Hvis de h jtydende BExL25D h jttaler anvendes ved h je omgivende temperaturer...

Страница 11: ...2 Ontplofbaar gas luchtmengsel is onwaarschijnlijk en indien dit ontstaat zal het waarschijnlijk slechts korte tijd aanwezig blijven Gasgroeperingen Groep IIA Propaan Groep IIB Ethyleen Groep IIC 55 C...

Страница 12: ...rtels worden gebruikt die zijn goedgekeurd voor Ex d toepassingen geschikt zijn voor het bekabelingstype dat wordt gebruikt en voldoen aan de vereisten van de norm EN60079 14 2008 IEC60079 14 2007 ten...

Страница 13: ...normale Zone 2 M lange d air et de gaz explosif ne pouvant pas survenir et qui dans le cas contraire serait pr sent que tr s bri vement Groupes de gaz Groupe IIA Propane Groupe IIB Ethyl ne Groupe IIC...

Страница 14: ...cations Ex d peuvent tre utilis s et ils doivent tre ad quats pour le type de c ble utilis et r pondre aux exigences d installation d antid flagrant Ex d de norme EN60079 14 2008 IEC60079 14 2007 AVER...

Страница 15: ...Luft Mischung vorliegen Zone 2 Explosive Gas Luft Mischung unwahrschein lich und sollte sie doch auftreten dann nur kurzfristig Gasgruppen Gruppe IIA Propan Gruppe IIB thylen Gruppe IIC 55 C Wasserst...

Страница 16: ...abeltyp geeignet sein und zudem den Anforderungen der Ex d Norm zur Installation schwer entflammbarer Ger te EN60079 14 2008 IEC60079 14 2007 entsprechen SICHERHEITSHINWEIS Wenn die BExL25D High Outpu...

Страница 17: ...esplosivo durante il normale funzionamento Zona 2 Non probabile che sia presente gas esplosivo e se esso dovesse essere presente potr esserlo solo per un breve periodo di tempo Gruppi di gas Gruppo I...

Страница 18: ...ngressi per premistoppa con filettature M20 x1 5 Utilizzare solo premistoppa approvati per le applicazioni Ex d essi inoltre devono essere adeguati al tipo di cavo in uso e devono rispettare gli stand...

Страница 19: ...losiv gass luft blanding som ikke vanligvis vil forekomme og om den gj r det kun vil forekomme i kort tid Gassgrupperinger Gruppe IIA Propan Gruppe IIB Etylen Gruppe IIC 55 C Hydrogen og acetylen Utst...

Страница 20: ...elmuffer godkjent for Ex d bruk kan brukes og de m v re egnet for typen kabel som brukes samt overholde kravene i standarden for Ex d flammesikker installering EN60079 14 2003 IEC60079 14 2007 SIKKERH...

Страница 21: ...va em funcionamento normal Zona 2 Improbabilidade de ocorr ncia de mistura gasosa explosiva mesmo que tal ocorra s ser por per odo curto Grupos de gases Grupo IIA Propano Grupo IIB Etileno Grupo IIC 5...

Страница 22: ...ara aplica es prova de explos o que devem ser adequados ao tipo de cabo a ser usado e satisfazer tamb m os requisitos da norma EN60079 14 2008 IEC60079 14 2007 relativa instala o prova de fogo e de ex...

Страница 23: ...s posible ocurra durante el funcionamiento normal Zona 2 Mezcla explosiva improbable de aire y gas que de producirse lo har s lo por breve tiempo Grupos de gas Grupo IIA Propano Grupo IIB Etileno Grup...

Страница 24: ...cable aprobados para aplicaciones Ex d los cuales deben ser adecuados para el tipo de cable que se est utilizando adem s de satisfacer los requisitos de la norma EN 60079 14 2008 IEC60079 14 2007 para...

Страница 25: ...al drift Zon 2 Explosiv gasblandning f rv ntas f rekomma s llan och d endast kortvarigt Explosionsgrupper Grupp IIA Propan Grupp IIB Etylen Grupp IIC 55 C V te och acetylen Kategori p utrustning 2G T...

Страница 26: ...kabeling ngar med M20 x 1 5 g nga Endast kabelgenomf ringar godk nda f r Ex d bruk f r anv ndas Dessa m ste passa den typ av kabel som anv nds och dessutom uppfylla kraven f r explosionst t kapsling E...

Страница 27: ...004 Directive 89 106 EEC Construction Products Directive CPD BExS110D24DC BExS120D24DC tones 2 3 9 15 16 17 only Notified Body for EC type Examination VdS Schadensverh tung GmbH Notified Body No 0786...

Отзывы: