6) 

Location and Mounting

 

 

The  location  of  the  unit  should be  made  with  due  regard  to 
the  area  over  which  both  the  sounder  and  beacon  warning 
signal  must  be  audible  and  visible.  The  unit  should  only  be 
fixed to services that can carry the weight of the unit. 
 
The unit should be securely bolted to a suitable surface using 
the  7mm diameter  boltholes  in  the stainless  steel  U  shaped 
mounting  bracket  (see  figure  1).  The  angle  can  then  be 
adjusted in the direction such that its warning signals can be 
both heard and seen. This can be achieved by loosening the 
two large bracket screws in the side of the unit,  which  allow 
adjustment in steps of 18

°

. On completion of the installation 

the  two  large  bracket  adjustment  screws on  the  side  of  the 
unit  must  be  fully  tightened  to  ensure  that  the  unit  cannot 
move in service. 
 
 

 

 

 

7) 

Safety Warning (Electrostatic Hazard)

 

 

The acoustic horn section is made of ABS Plastic, therefore 
to  avoid  a  possible  ELECTROSTACTIC  CHARGE  the  unit 
must only be cleaned with a damp cloth. 

 

8) 

Access to the Flameproof Enclosure

 

 

In order to connect the electrical supply cables to the unit it is 
necessary  to  remove  the  beacon  section  to  gain  access  to 
the flameproof chamber. To achieve this remove the four M6 
hexagon socket head screws (see figure 2) and withdraw the 
beacon  section  taking  extreme  care  not  to  damage  the 
flameproof joints in the process.  
 
Note  the  four 

M6 screws are Class  A4-80 stainless  steel 

and  only  screws of  this  category  can  be used  on  these 
units. 

It  is  therefore  important  that  these  screws  and  their 

spring washers are kept in a safe place during installation. 
 
On completion of the cable wiring installation the flameproof 
joints should be inspected to ensure that they are clean and 
that  they  have  not  been  damaged  during  installation.  Also 
check  that  the  earth  bonding  wire  between  the  two  casting 
sections  is  secure  and  the  ‘O’  ring  seal  is  in  place.  When 
replacing the beacon section casting, ensure that it is square 
with  the  sounder  section  chamber  casting  before  inserting. 
Carefully push the beacon section in place allowing time for t 
 

 
 
the air to be expelled. Only after the beacon section casting is 
fully in place should the four M6 Stainless Steel A4-80 cover  
bolts  and  their  spring  washer  be  inserted  and  tightened 
down.  If  the beacon  section  jams  while  it  is  being  inserted, 
carefully remove it and try again. Never use the cover bolts to 
force the beacon section casting into position. 
 

 

 

9) 

Power Supply Selection 

 

It is important that a suitable power supply is used to run the 
unit.  The  power  supply  selected  must  have  the  necessary 
capacity  to  provide  the  input  current  to  all  of  the  units 
connected  to  the system The sounder  and beacon  sections 
can  both  be  wired  to  the  same  power supply  or  to  different 
power supplies 
  
The  following  table  shows  the  input  current  taken  by  the 
sounder section and beacon section of the various units:- 

 

Unit Type 

Input  

 

Sounder   

Max. 

 

 

Voltage   

Current               I/P Volts

 

 
BExCS110-05D 

24V DC   

265mA 

 

30V 

BExCS110-05D 

12V DC   

195mA 

 

15V 

BExCS110-05D 

48V DC   

130mA 

 

58V 

BExCS110-05D 

230V AC   

56mA 

 

264V 

BExCS110-05D 

115V AC   

110mA 

 

126V 

 

Unit Type 

Input  

 

Beacon   

Max. 

 

 

Voltage   

Current                I/P Volts

 

 
BExCS110-05D 

24V DC   

300mA 

 

30V 

BExCS110-05D 

12V DC   

750mA 

 

15V 

BExCS110-05D 

48V DC   

180mA 

 

58V 

BExCS110-05D 

230V AC   

55mA 

 

264V 

BExCS110-05D 

115V AC   

140mA 

 

126V 

 

The above table also shows the maximum voltages at which 
the units can be operated. 

 
Sounder Section 

The input current to the sounder section will vary according to 
the voltage input level and the frequency of the tone selected. 
The  current  levels  shown  above  are  for  the  440Hz 
Continuous tone @ nominal input voltage. The 24V and 48V 
DC units and the 230V AC, 115V AC units have a switching 
voltage regulator circuit and therefore the input current  level 
will  decrease  slightly  as  the  input  voltage  in  increased  and 
will increase slightly as the input voltage is reduced. The 12V 
units do not have a voltage regulator and therefore their input 
current will increase when the input voltage is increased. 