background image

 

 

European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH

www.e2s.com

 

Tel: +44 (0)208 743 8880

Document No. D210-00-711-IS

 

Issue 6

 

12-09-2022

Sheet 6 of 6

 

15 

Interchangeable & Spare Parts 

 

 

The beacon covers are interchangeable, contact E2S Ltd for a 
replacement cover available in various colours.  

 

To change the cover, unscrew the M5 socket head screws and 
remove the M5 screws, M5 spring & flat washers.  

 

Fig. 7 Removal of cover 

 

Remove  the  guard  and  replace  the  old  cover  with  the  new 
cover.  

 

Fig. 8 Changing of cover 

Fit the guard back on to the cover and casting, align the holes 
of  the  guard,  cover  and  casting.  To  reattach  the  cover,  the 
fixings MUST be in the order shown in figure 9.    

 

Fig. 9 Cover and Guard Fixtures 

 

16  Maintenance, Overhaul & Repair 

 

Maintenance,  repair  and  overhaul  of  the  equipment  should 
only  be  carried  out  by  suitably  qualified  personnel  in 
accordance with the current relevant standards: 

 

EN60079-19 
IEC60079-19 

Explosive atmospheres - Equipment 
repair, overhaul and reclamation 

 

EN 60079-17 
IEC60079-17 

Explosive atmospheres - Electrical 
installations inspection and maintenance 

 

The  acoustic  horn  is  made  out  of  ABS  plastic,  therefore  to 
avoid a possible ELECTROSTACTIC CHARGE the unit must 
only be cleaned with a damp cloth. 

 

Units must not be opened while an explosive atmosphere is 
present. 

 

If  opening  the  unit  during  maintenance  operations  a  clean 
environment must be maintained and any dust layer removed 
prior to opening the unit. 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Warning – Hot surfaces. External surfaces 
and internal components may be hot after 
operation, take care when handling the 
equipment. 

M5x16 Hex Socket Screw 

M5 Spring Washer 

M5 Plain Washer 

Guard 

Cover 

M5x16 Hex 
Socket Screw 

Old 
Cover 

New 
Cover 

Содержание BExCBGL2-05D-P

Страница 1: ...shows the input current taken by the various units Nominal current at nominal voltage Table 1 Electrical Ratings It is important that a suitable power supply is used to run the equipment The power su...

Страница 2: ...ve gas air mixture not likely to occur in normal operation and if it does it will only exist for a short time Gas Groupings Group IIA Propane Group IIB Ethylene Group IIC Hydrogen Acetylene Temperatur...

Страница 3: ...to ensure that the unit cannot move in service Fig 1 Fixing Location for Combined Beacon Beacon 7 Access to the Flameproof Enclosure To access the Ex d chamber remove the four M6 hexagon socket head...

Страница 4: ...ls which are both located on the terminal chamber section of the unit Fig 3 Internal View of Cover When using the internal earth terminal ensure that the stainless steel M4 flat washer is between the...

Страница 5: ...line resistor is used it must have a minimum resistance value of 3k3 and a minimum power rating of 0 5 watts or a minimum resistance value of 500 and a minimum power rating of 2 watts The resistor mus...

Страница 6: ...epair Maintenance repair and overhaul of the equipment should only be carried out by suitably qualified personnel in accordance with the current relevant standards EN60079 19 IEC60079 19 Explosive atm...

Страница 7: ...2022 BExCBGL2 05D DC LED XENON BEACONS WIRING DIAGRAM INTRODUCTION INTRODUCTION 1 RSR 05 09 2022 ve in ve in ve out ve out Single Stage Configuration Simultaneous Operation Config 1a Line Monitoring S...

Страница 8: ...TE ISSUE DATE APPROVED CHECKED DATE DATE DRAWN WEIGHT Kg SURFACE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO NOT SCALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F...

Страница 9: ...ality Assurance Notification ModuleD SIRA 05 ATEX M342 Provisions fulfilledby theequipment II 2G Ex db IIB T6 to T4 Gb II 2D Ex tb IIIC T65 C to T130 CDb IP6X Dust Protectionto EN60079 0 EN60079 31 St...

Страница 10: ...r Date andPlace of Issue London 23 12 2020 EU Declaration of Conformity On behalf of European SafetySystems Ltd I declarethat on the date the equipment accompanied by this declaration is placed onthem...

Страница 11: ...Chester CH4 9JN UK Quality Assurance Notification Module D CSAE 22UKQAN0046 Provisions fulfilled by the equipment II 2G Ex db IIB T6 T4 Gb II 2D Ex tb IIIC T65 C T130 Db IP6X Dust Protection to EN6007...

Страница 12: ...and Place of Issue London 12 09 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the m...