11. 

AC Wiring

 

A 4-way terminal block is provided on the AC chamber beacon 
for power. There are 2-off Live and 2-off Neutral terminals in 
total.  A  4-way  terminal  block  is  provided  on  the  AC  cover 
beacon  for  power.  There  are  2-off  Live  and  2-off  Neutral 
terminals in total.  

 

 

 

 

Fig. 4a Chamber Beacon AC Terminals 

 

Fig. 4b Cover AC Terminals 

 

12  DC Wiring 

 

A 4-way terminal block is provided on the DC chamber beacon 
for power. There are 2-off +ve and 2-off -ve terminals in total. 
A 4-way terminal block is provided on the AC cover beacon for 
power. There are 2-off +ve and 2-off -ve terminals in total.  

 

 

 

Fig. 5a Chamber DC Terminals 

 

 

Fig. 5b Cover DC Terminals 

 
 

12.2 

Line Monitoring 

 

On  BExCBGL2-05D-P  DC  units,  dc  reverse  line  monitoring 
can be used if required. All DC beacons have a blocking diode 
fitted in their supply input lines. An end of line monitoring diode 
or an end of line monitoring resistor can be connected across 
the +ve and –ve terminals. If an end of line resistor is used it 
must  have  a  minimum  resistance  value  of  3k3Ω  and  a 
minimum power rating of 0.5 watts or a minimum resistance 
value of 500Ω and a minimum power rating of 2 watts. 

 

The resistor must be connected directly across the +ve and -
ve terminals as shown in the following drawing. The resistor 
leads should be kept as short as possible.  

 

 

Fig. 6 End of Line Resistor Placement 

 

13  Wiring the combined beacon/beacon for 

simultaneous operation  

 

Both beacon sections can be wired to the same input supply 
so  that  they  operate  simultaneously  or  they  can  be  wired  to 
separate input supplies so they can be operated independently 
(see wiring diagrams D210-06-711 or D210-06-715). 

 

 

If the chamber and cover sections are connected to the same 
input supply. The incoming cables should be connected to the 
input terminals on the cover section beacon board and the two 
link wires, that are supplied with the unit, should be used to link 
the  supply  from  the  interconnecting  terminals  on  the  cover 
section  beacon  board  down  to  the  supply  terminals  on  the 
chamber section beacon board. 

 
 
 
 
 

 

 

N  

 

Interconnecting Terminals 
to 2

nd

 beacon PCB 

(simultaneous 
mode of operation) 

Flip / Flop 
Pin Header 

 

 

+  

 

Flip / Flop 
Pin Header 

Interconnecting Terminals 
to 2

nd

 beacon PCB 

(simultaneous 
mode of operation) 

End of Line Resistor

 

+

 

 

-

 

 

-

 

 

S2

 

 

S3

 

 

L

 

 

N

 

 

N

 

 

E

 

 

E

 

Содержание BExCBGL2-05D-P

Страница 1: ...shows the input current taken by the various units Nominal current at nominal voltage Table 1 Electrical Ratings It is important that a suitable power supply is used to run the equipment The power su...

Страница 2: ...ve gas air mixture not likely to occur in normal operation and if it does it will only exist for a short time Gas Groupings Group IIA Propane Group IIB Ethylene Group IIC Hydrogen Acetylene Temperatur...

Страница 3: ...to ensure that the unit cannot move in service Fig 1 Fixing Location for Combined Beacon Beacon 7 Access to the Flameproof Enclosure To access the Ex d chamber remove the four M6 hexagon socket head...

Страница 4: ...ls which are both located on the terminal chamber section of the unit Fig 3 Internal View of Cover When using the internal earth terminal ensure that the stainless steel M4 flat washer is between the...

Страница 5: ...line resistor is used it must have a minimum resistance value of 3k3 and a minimum power rating of 0 5 watts or a minimum resistance value of 500 and a minimum power rating of 2 watts The resistor mus...

Страница 6: ...epair Maintenance repair and overhaul of the equipment should only be carried out by suitably qualified personnel in accordance with the current relevant standards EN60079 19 IEC60079 19 Explosive atm...

Страница 7: ...2022 BExCBGL2 05D DC LED XENON BEACONS WIRING DIAGRAM INTRODUCTION INTRODUCTION 1 RSR 05 09 2022 ve in ve in ve out ve out Single Stage Configuration Simultaneous Operation Config 1a Line Monitoring S...

Страница 8: ...TE ISSUE DATE APPROVED CHECKED DATE DATE DRAWN WEIGHT Kg SURFACE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO NOT SCALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F...

Страница 9: ...ality Assurance Notification ModuleD SIRA 05 ATEX M342 Provisions fulfilledby theequipment II 2G Ex db IIB T6 to T4 Gb II 2D Ex tb IIIC T65 C to T130 CDb IP6X Dust Protectionto EN60079 0 EN60079 31 St...

Страница 10: ...r Date andPlace of Issue London 23 12 2020 EU Declaration of Conformity On behalf of European SafetySystems Ltd I declarethat on the date the equipment accompanied by this declaration is placed onthem...

Страница 11: ...Chester CH4 9JN UK Quality Assurance Notification Module D CSAE 22UKQAN0046 Provisions fulfilled by the equipment II 2G Ex db IIB T6 T4 Gb II 2D Ex tb IIIC T65 C T130 Db IP6X Dust Protection to EN6007...

Страница 12: ...and Place of Issue London 12 09 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the m...

Отзывы: