warning signals
2S
EUROPEAN SAFETY SYSTEMS LTD
IMPRESS HOUSE
MANSELL ROAD
ACTON
LONDON W3 7QH
WWW.E2S.COM
C
THIS DRAWING AND ANY INFORMATION OR DESCRIPTIVE
MATTER THEREIN IS COMMUNICATED IN CONFIDENCE AND
IS THE COPYRIGHT PROPERTY OF EUROPEAN SAFETY
SYSTEMS LTD. NEITHER THE WHOLE OR ANY EXTRACT MAY
BE DISCLOSED, LOANED, COPIED OR USED FOR
MANUFACTURING OR TENDERING PURPOSES WITHOUT THEIR
WRITTEN CONSENT.
EUROPEAN SAFETY SYSTEMS LTD.
AS PER LATEST DATE OF ISSUE SHOWN ABOVE
DRAWING TO BS8888:2000
GEOMETRIC TOLERANCES TO ISO1101:1983
LINEAR DIMENSIONAL TOLS
ANGULAR DIMENSIONAL TOLS
STANDARDS
MOD No.
REASON - INITIAL - DATE
ISSUE
DATE
APPROVED
CHECKED
DATE
DATE
DRAWN
WEIGHT (Kg)
SURFACE FINISH
MATERIAL
ALTERNATIVE MATERIAL
SHEET
SCALE
TITLE
A3
IF IN DOUBT, ASK -
DO NOT SCALE
ALL DIMENSIONS IN MM
DRAWING NUMBER
A
B
C
D
E
F
G
10
9
G
F
E
7
8
6
5
D
C
1
3
4
2
A
B
D156-06-401
R.N.POTTS
OF
GNExB2 LD2 BEACON
NTS 1
1
A
FORMAT UPDATE
MA - 03/12/2021
B
INTRODUCTION
J.S - 14/11/19
GNExB2 LD2
R.N.POTTS
J.SPILLER
14/11/19
WIRING DIAGRAMS
Stage 3
R1
-
-
S2
S3
DC LED GNExB2LD2 UNITS
Line Monitoring
Power: +ve & -ve
14/11/19
14/11/19
OPTIONAL LINE MONITORING RESISTOR, CUSTOMER SUPPLIED,
RECOMMENDED MINIMUM VALUES:
R1
500Ω MIN, 2W MIN OR 3K3Ω MIN, 0.5W MIN
+
+
Stage 2
-ve IN
-ve OUT
+ve OUT
+ve IN
L
L
Neutral IN
Neutral OUT
Live OUT
Live IN
Earth
Earth
N
N
E
E
AC LED GNExB2LD2 UNITS
Power: Live & Neutral
RE-DRAWN IN 2D
NOTES, TERMINALS & EOL RESISTOR ADDED
DAH 17/12/19
C