101,6 mm
101,6 mm
48,4 mm
48,4 mm
763 mm
763 mm
442 mm
332 mm
185 mm
370 mm
105 mm
E-Tech W
: 664Y6500 • B
en
10
EN
FR
NL
ES
IT
DE
PL
RU
INSTALLATION
DIMENSIONS
Min.
25 mm
Min.
400 mm
Min.
200 mm
WALL MOUNTING
• The boiler must be fixed to a non flammable
wall.
• Observing the clearances shown below, drill 2
off 14mm x 100mm holes.
• Fit the 2 bolts supplied and hang the wall
bracket.
• Fit washers and nuts
• Hang the boiler
FROST PROTECTION
the boiler is NOT fitted with frost protection. If the boiler is being installed in a position where freezing
could take place, then a suitable external frost thermostat should be fitted.
CONNECTING TO THE SYSTEM
the boiler is designed to operate on a sealed system (ie. no open vent or feed and expansion cistern)
Hot water expansion within the system is taken up by the internal 10 litre expansion vessel. This is
suitable for systems up to 160 litres capacity. If the system capacity is more than this then an additional
expansion vessel may be required.This can be fitted external to the boiler at a convenient place on the
pipework.
Please note that the circulation pump is fitted to the flow connection.
INSTALLATION ROOM
The appliance must be positioned in such a way as to be easily accessible at all times. In addition, the
following minimum distances around the appliance must be complied with.