49
Display definitions and troubleshooting guide.
Displayed on
screen.
Definition.
Solution.
In normal operating mode.
rdy
Unit is standing by and ready for next instruction. Trigger to run a required routine.
ac
Charger powered down due to Vac mains
interuption.
Check 220VAC or 29Vac supply to the unit.
Check 500mA fast blow fuse in the 220Vac connector.
Bat
Battery is either disconnected or discharged.
Check the 10A fuse in the battery lead.
Allow 8-10 hours uninterrupted charge before trying to operate the unit
again. If the battery has not recovered after this, then replace the battery.
rel
Gearbox manual release is in released (Manual)
position.
Lower the release lever to engage gearbox.
Test manual release lever reed switch.
Check that the manual release lever magnet has not been dislodged.
irb
Infra-red beams circuit is being triggered.
Remove obstruction from the path of the safety beams.
Check that beams are powered and functioning properly. Ensure the safety
beam circuit end of line resistor has been installed properly as per this
manual.
Hol
Control card is in Holiday Lock-out mode.
Follow the steps on page 42 to deactivate Holiday Lock-out.
par
Control card is in Party mode.
Follow the steps on page 43 to deactivate Party mode.
col
Multiple collision lock-out active.
See page 32 and “Selecting a safety level” on page 20.
for
Safety overload triggered by physical overload.
See page 32 and “Selecting a safety level” on page 20.
ref
Referencing the gate closed position.
See “Referencing the closed position” on page 10.
e-l
Failure to see the closed limit.
See Installing the limit actuator on page 16.
opn
Gate is open.
Trigger gate to close.
pr9
Control card is in Programming mode.
Press and release X to exit programming mode.
e1
Revolution counter/encoder failure.
Ensure control card is fastened down correctly and that the ring magnet is
installed correctly in place atop the motor shaft.
e3
Motor is disconnected, motor fuse is fused or
electric motor is faulty.
Ensure the motor is connected correctly. Test the 10A motor fuse. Test the
electric motor by disconnecting it from the control card and running it on a
battery directly.
In programming mode.
abt
Procedure aborted via the “X” button.
Begin the procedure again.
dne
Procedure completed.
Continue on to another programming option or exit programming.
e-l
Closed limit not installed correctly.
See Installing the limit actuator on page 16.
for
While buzzer beeps 20 times. Excessive gate
resistance.
Repair gate rolling load, so that it remains below the rated load specified
on page 4.
ful
Receiver memory is full.
Delete any user addresses no longer in use.
to
Time out error while programming a remote.
Begin transmitting with the remote before pressing set. Remote maybe
damaged or faulty. Ensure the remote does indeed transmit.
dec
Decoding error.
The remote does not use a format that is compatible with the receiver.