7
8
Installation :
When installation, keep the device far away
t h e h e a t s e n s i t i v e o b j e c t s a n d
explosivessensitive objects, leave at least
50CM of free space around the device.
When the device put on horizontal place, the
device must be placed directly on theplace,
and devices must be secured with a mounting
holder.
When rigging the devices on the truss and the
head face to the floor.Insert the quick-lock
fasteners of the first mounting holder into the
respective holes on the bottom ofthe device.
Ti g h t e n t h e q u i c k - l o c k f a s t e n e r s f u l l y
clockwise. Install the second mountingholder.
And the safety rope must be used at same
time.
Safety Rope
Hook
Please use qualified safety-rope, which can
hold at least 10 times the weight of thefixture.
You must only use safety-ropes with quick
links with screw cap. Pull the safetyrope
through the hole on the bottom of the base
and over the trussing system etc. Insertthe
end in the quick link and tighten the fixation
screw. A safety rope which already holdthe
strain of a crash or which is defective must not
be used again.
*
Installation :
Take out the barndoor,operation followed by the overview.
Open the spring,hold the
both side of spring and
take one side from the
slot.
Put the barndoor with
filter in the slot.
Use spring clip stuck the
barndoor.
Installation Of Barndoor:
1.Installation:
Please use xlr-xlr wires connect the dmx output of the controller with the dmx input of the
first device, and connect the dmx output of the first device with the dmx input of the second
device, always connect one output with the input of the next device until all devices are
connected.
2.Dmx512 connection:
The person involved with the power connection must be qualified, and has the electrical
engineering certificate.
Connect the device to the powe cable with the power plug.
The earth has to be connected.
Power consumption 150W, input power supply AC100V-240V, 50/60Hz.
3.Connection with power cable:
Please use qualified XLR-XLR DMX cables.
*
Important note:
the specification of power line is 3G1.5 with a maximum current 13A,when
power is 200V-240V, use grey plug power interconnection on the device, each group do not
exceed 16 sets of equipment; when power is 100V-120V, each interconnect please do not
exceed 8 sets of equipment!
*
AC 100V-240V,50/60Hz
*
Hook and safety rope not included.