![background image](http://html.mh-extra.com/html/e-h-wachs/ep-424/ep-424_user-manual_519210053.webp)
Chapter 5, Operating Instructions: Mounting the Mandrel on the Pipe
E.H. Wachs
Part No. 81-MAN-00, Rev. C
47
20.
Move the indicator around the pipe end by rotating the mounting collar. Check the reading on
the indicator dial to measure how far the mandrel is off center.
NOTE
Do not adjust the mandrel centering screws if stud spac ers (23-203-00) are installed.
The mandrel position cannot be adjusted with the spacers.
Figure 5-25. Sweep the indicator around the pipe sur face to check centering of the mandrel.
You can center on either the O.D. or the I.D. of the pipe, as required for the operation.