5-1
September 1994
Part No. 001-2008-300
SECTION 5 REPEATER PROGRAMMING
5.1 CREATING A NEW FILE
An example will be used to show the program-
ming for a new file.
NOTE: At any point in the programming sequence, if
F1 is selected, a help screen appears to explain the
menu selection highlighted at that point.
5.1.1 SELECT REPEATER TO EDIT
Universal Station is selected to program. When
no file exists with programmed parameters, the default
is selected and edited.
1. Highlight EDIT, press Enter.
2. Highlight Select Rptr, press Enter.
3. Default is the only Universal Station in the Repeater
list, press Enter.
4. Highlight Setup Parameters, press Enter (or press
F4).
5. The Setup Parameters screen appears (see Figure
5-1). Fill in the parameters for this Universal Sta-
tion. A brief description of the parameters is in
Table 5-1. Full descriptions are in Section 4.3.1.
6. Select parameters, press F2 to accept.
7. Highlight Alarm Configuration and press Enter, if
alarms are to be configured.
8. Program the Alarms to be configured (see Section
4.3.3), press F2 to accept.
9. Highlight FILE, press Enter.
10.Highlight Save, press Enter.
11. Type in a valid DOS filename. For this example
sta1.qx is used.
12.The file consists of default and Rptr 1 under the file-
name of sta1.qx.
5.2 ADDING A REPEATER TO A FILE
The example used for Station 1 will again be
used to add repeaters to the filename sta1.qx.
1. Highlight EDIT, press Enter.
2. Highlight Select Rptr, press Enter.
3. The Repeater list shown for this file includes default
and Rptr 1. These contain the same parameters with
the exception that when selected for edit, the pro-
grammed information can be overwritten and the
data lost.
4. Highlight Default, press Enter.
5. Highlight Setup Parameters, press Enter.
6. Change the Repeater Number and other parameters
as required for this Universal Station, press F2.
7. Highlight Alarm Configuration and press Enter, if
alarms are to be configured.
8. Program the Alarms to be configured (see Section
4.3.3), press F2 to accept.
9. Highlight FILE, press Enter.
10.Highlight Save, press Enter.
11. Rptr 2 is added to the List in file sta1.qx.